{"id":4786,"date":"2016-04-06T00:47:39","date_gmt":"2016-04-06T00:47:39","guid":{"rendered":"http:\/\/www.eisnersafety.com\/eisnersafetycom\/?p=4786"},"modified":"2020-02-26T05:45:14","modified_gmt":"2020-02-26T05:45:14","slug":"iec-60601-1-9-required-for-brazil-near-end-of-2016","status":"publish","type":"post","link":"https:\/\/eisnersafety.com\/eisnersafetycom\/2016\/04\/06\/iec-60601-1-9-required-for-brazil-near-end-of-2016\/","title":{"rendered":"IEC 60601-1-9 required for Brazil Near End of 2016"},"content":{"rendered":"<h3><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-thumbnail wp-image-4788\" src=\"http:\/\/www.eisnersafety.com\/wp-content\/uploads\/2016\/04\/brazil-flag-150x150.png\" alt=\"brazil-flag\" width=\"150\" height=\"150\">Brazil IEC 60601-1-9 required Near End of 2016 &#8211; Are You Ready?<\/h3>\n<p style=\"padding-left: 30px;\">ANVISA (The&nbsp;Brazil National Health Surveillance Agency) issued the&nbsp;rule IN 4&nbsp;on September 24, 2015&nbsp;&nbsp;(that superseded the IN 11, dated December 16, 2014) which requires the standard ABNT NBR IEC 60601-1:2010 + Emenda IEC:2012 &#8211; the Portuguese translation of IEC 60601-1:2005 + Amendment 1:2012 (Edition 3.1 or 3rd edition + Amendment 1). &nbsp;This standard is required for any new product seeking ANVISA approval since September 24, 2015 and going forward.<\/p>\n<p style=\"padding-left: 60px;\">Before we get to the 60601-1-9 issue let&#8217;s talk a little about which version of 60601-1 applies. &nbsp;If you have an INMETRO certificate that met 60601-1 3rd ed. you are ok until&nbsp;you have to rectify your product or your certificate expires. &nbsp;If the Particular Standard 60601-2-XX &nbsp;is still based on the 2nd ed. of 60601-1 then you still can use the 2nd edition of 60601-1. &nbsp;But check the IN 4 before you move forward that way to make sure you are using the proper version of the applicable standards. &nbsp;For the EMC standard you only need to deal with the 60601-1-2 3rd ed. which is equivalent to the 2007 edition of IEC 60601-1-2 and is the less stringent standard compared to <a href=\"http:\/\/www.eisnersafety.com\/iec-60601-1-22014-4th-ed-what-is-the-impact-of-this-puzzle-on-your-product-design\/\" target=\"_blank\" rel=\"noopener noreferrer\">4th ed&nbsp;of&nbsp;60601-1-2<\/a>.<\/p>\n<p style=\"padding-left: 30px;\">Along with 60601-1 there were a long list of other 60601 based standards in the Notice including the 60601-1-9 standard for &#8220;environmentally conscious design of medical electrical equipment&#8221;. &nbsp;If you would like a copy of this notice&nbsp;please e-mail&nbsp;me at Leo@EisnerSafety.com. &nbsp;I believe that Brazil is the&nbsp;first country that is mandating the use of 60601-1-9&nbsp;. The full IEC standard title is <em>&#8220;IEC 60601-1-9:2007 +&nbsp;Amendment&nbsp;1:2013 Medical&nbsp;electrical&nbsp;equipment &#8211; Part 1-9: General requirements for basic&nbsp;safety and essential performance &#8211; Collateral&nbsp;Standard: Requirements for <span style=\"text-decoration: underline;\">environmentally&nbsp;conscious design<\/span>&#8220;. &nbsp;<\/em>The Brazilian version of the standard is&nbsp;ABNT NBR IEC 60601-1-9:2014 which is translated into Portuguese and the text is identical to IEC 60601-1-9:2007 + A1:2013.<\/p>\n<p style=\"padding-left: 30px;\">ANVISA is requiring compliance to the standard by December 1, 2016 specifically for the&nbsp;clauses&nbsp;4.1, 4.5.2 and 4.5.3 of the standard. &nbsp;So, the documentation needed will include the identification of environmental aspects (clause 4.1), instructions for minimizing <span class=\"s1\" style=\"line-height: 1.5;\">environmental impact<\/span>&nbsp;during&nbsp;<span class=\"s1\" style=\"line-height: 1.5;\">normal use (clause 4.5.2), and information for end of life management (clause 4.5.3).&nbsp;<\/span><\/p>\n<p style=\"padding-left: 30px;\">If you need help with IEC 60601-1, any in the Series of Standards or any National Version of these standards&nbsp;please&nbsp;email Leo Eisner at&nbsp;<a href=\"mailto:Leo@EisnerSafety.com\">Leo@EisnerSafety.com<\/a>, or call Leo at +1 (503)-244-6151. He is the Principal Consultant of <a href=\"http:\/\/bit.ly\/EisnerSafetyConsultants\">Eisner Safety Consultants<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Brazil IEC 60601-1-9 required Near End of 2016 &#8211; Are You Ready? ANVISA (The&nbsp;Brazil National Health Surveillance Agency) issued the&nbsp;rule IN 4&nbsp;on September 24, 2015&nbsp;&nbsp;(that superseded the IN 11, dated December 16, 2014) which requires the standard ABNT NBR IEC<\/p>\n","protected":false},"author":4,"featured_media":4788,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[1],"tags":[15,1297,1298,1299,1300,561,173,840,27,218,691,1301,1302],"class_list":["post-4786","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-60601-1","tag-60601-1-9","tag-abnt-nbr-iec-60601-1","tag-abnt-nbr-iec-60601-1-9","tag-anvisa","tag-brazil","tag-esc","tag-esc-news","tag-escnews","tag-iec-60601-1","tag-iec-60601-1-3-1","tag-iec-60601-1-9","tag-inmetro"],"_links":{"self":[{"href":"https:\/\/eisnersafety.com\/eisnersafetycom\/wp-json\/wp\/v2\/posts\/4786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eisnersafety.com\/eisnersafetycom\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/eisnersafety.com\/eisnersafetycom\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/eisnersafety.com\/eisnersafetycom\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/eisnersafety.com\/eisnersafetycom\/wp-json\/wp\/v2\/comments?post=4786"}],"version-history":[{"count":1,"href":"https:\/\/eisnersafety.com\/eisnersafetycom\/wp-json\/wp\/v2\/posts\/4786\/revisions"}],"predecessor-version":[{"id":6682,"href":"https:\/\/eisnersafety.com\/eisnersafetycom\/wp-json\/wp\/v2\/posts\/4786\/revisions\/6682"}],"wp:attachment":[{"href":"https:\/\/eisnersafety.com\/eisnersafetycom\/wp-json\/wp\/v2\/media?parent=4786"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/eisnersafety.com\/eisnersafetycom\/wp-json\/wp\/v2\/categories?post=4786"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/eisnersafety.com\/eisnersafetycom\/wp-json\/wp\/v2\/tags?post=4786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}