<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>62304 &#8211; Eisner Safety Consultants</title>
	<atom:link href="https://eisnersafety.com/tag/62304/feed/" rel="self" type="application/rss+xml" />
	<link>https://eisnersafety.com</link>
	<description>Regulatory &#38; Safety Experts for Global Medical Device Approvals</description>
	<lastBuildDate>Thu, 18 Jul 2013 04:44:59 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://eisnersafety.com/wp-content/uploads/2025/08/favicon-45x45.png</url>
	<title>62304 &#8211; Eisner Safety Consultants</title>
	<link>https://eisnersafety.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>South Korea MFDS Amends it’s Medical Devices Act &#038; Will Require IEC 60601-1, 3rd ed + Amendments</title>
		<link>https://eisnersafety.com/2013/07/18/south-korea-mfds-amends-its-medical-devices-act-will-require-iec-60601-1-3rd-ed-amendments/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=south-korea-mfds-amends-its-medical-devices-act-will-require-iec-60601-1-3rd-ed-amendments</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Thu, 18 Jul 2013 04:44:59 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[3rd ed. (2005) + Amendments]]></category>
		<category><![CDATA[60601]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[60601-1 3rd ed. Amendment 1]]></category>
		<category><![CDATA[60601-1 A1 12]]></category>
		<category><![CDATA[60601-1 A1 2012]]></category>
		<category><![CDATA[60601-1 A1:12]]></category>
		<category><![CDATA[62304]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[A1 IEC 60601-1 3rd ed.]]></category>
		<category><![CDATA[A1 IEC 60601-1 3rd edition]]></category>
		<category><![CDATA[A1 IEC 60601-1:2005]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[AAMI ES60601-1/C1]]></category>
		<category><![CDATA[Amendment 1]]></category>
		<category><![CDATA[Amendment 1 to IEC 60601-1:2005]]></category>
		<category><![CDATA[amendments]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[Collateral Standard]]></category>
		<category><![CDATA[EN60601]]></category>
		<category><![CDATA[EN60601-1]]></category>
		<category><![CDATA[Enforcement of the Medical Devices Act]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[iec 60601]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[IEC 60601-1 + A1]]></category>
		<category><![CDATA[IEC 60601-1 3rd ed]]></category>
		<category><![CDATA[IEC 60601-1:05]]></category>
		<category><![CDATA[IEC 62304]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[IEC60601-1 3rd ed. Amendment 1]]></category>
		<category><![CDATA[KFDA]]></category>
		<category><![CDATA[Korea]]></category>
		<category><![CDATA[Korea's Ministry of Food and Drug Safety]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[medical device software]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[Medical Devices Act]]></category>
		<category><![CDATA[MFDS]]></category>
		<category><![CDATA[Ministry of Food and Drug Safety]]></category>
		<category><![CDATA[regulatory bodies]]></category>
		<category><![CDATA[safety standards]]></category>
		<category><![CDATA[software lifecycles]]></category>
		<category><![CDATA[South Korea]]></category>
		<category><![CDATA[South Korea's Ministry of Food and Drug Safety]]></category>
		<category><![CDATA[STED]]></category>
		<category><![CDATA[Summary Technical Documentation]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3435</guid>

					<description><![CDATA[There were three major changes to South Korea’s Medical Devices Act and the Enforcement of the Medical Devices Act as of 8 May 2013. Introduction of IEC 60601-1 (third edition) with amendments They will be requiring that for electrical medical]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">There were three major changes to South Korea’s Medical Devices Act and the Enforcement of the Medical Devices Act as of 8 May 2013.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span id="more-3435"></span></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><span style="text-decoration: underline;">Introduction of IEC 60601-1 (third edition) with amendments</span></strong></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">They will be requiring that for electrical medical devices these products will need to meet IEC 60601-1, 3<sup>rd</sup> ed. (2005) + Amendments*.   This requirement is effective for Class 3 &amp; 4 medical devices as of June 1 2014, for Class 2 medical devices as of June 1 2015 and lastly for Class 1 medical devices as of June 1 2016.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">* Depending on what this Amendment to the Medical Devices Act consider Amendments it could be just Amendments of the standard or it could include &amp; probably should consider the Corrigendums and Interpretation Sheets too.   All the possible current Amendments are Amendment 1:2012 + Corrigendums 1:2006 and 2:2007 for 3<sup>rd</sup> ed. and Corrigendum 1:2012 for ed. 3.1 + Interpretation Sheets 1:2008, 2:2009, &amp; 3:2013.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The notice also states that MFDS will lay down new safety standards for software as medical electrical equipments.  My guess is that they will require complying with IEC 62304 which is the standard for Medical Device Software Lifecycles as it has become very popular around the world for many national regulatory bodies.  We will have to wait and see what happens for this requirement, as the notice is not clear as to what standard(s) they will use as of now.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><span style="text-decoration: underline;">Introduction of the Summary Technical Documentation (STED)</span></strong></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">As of January 1 2014 Class 4 medical device applicants (except for IVD reagents) will be required to submit in the the STED format.  MFDS says that this will expedite the review timelines for the manufacturers and devices that are submitted.  Class 1, 2, &amp; 3 devices have the option of submitting in the STED format as of the date for the notification.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><span style="text-decoration: underline;">Revised “Regulations on Classification and Grades”</span></strong></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">MFDS announced several changes for the regulations on classification and grades covering the following issues:</span></p>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">94 new products are added under &#8220;cell manipulating kit for medical use&#8221;.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Definitions for 108 products have changed including for “heater systems”.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The Class of “dental color measuring devices” was down-classified to Class 1.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">67 commercial names including “warm bath equipment” are edited out.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The changes are effective as of the date of notification.</span></li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NB-MED issues FAQ on Implementation of EN62304:2006 w.r.t. MDD, V1.0</title>
		<link>https://eisnersafety.com/2013/04/19/nb-med-issues-faq-on-implementation-of-en623042006-w-r-t-mdd-v1-0/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=nb-med-issues-faq-on-implementation-of-en623042006-w-r-t-mdd-v1-0</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Fri, 19 Apr 2013 02:51:26 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[62304]]></category>
		<category><![CDATA[90/385/EC]]></category>
		<category><![CDATA[93/42/EEC]]></category>
		<category><![CDATA[98/79/EC]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[CE Mark]]></category>
		<category><![CDATA[CENELEC]]></category>
		<category><![CDATA[COCIR]]></category>
		<category><![CDATA[electromedical]]></category>
		<category><![CDATA[EN]]></category>
		<category><![CDATA[en 60601]]></category>
		<category><![CDATA[EN 62304]]></category>
		<category><![CDATA[EN 62304:2006]]></category>
		<category><![CDATA[EN62304]]></category>
		<category><![CDATA[EN62304:2006]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[EU Active Implantable Medical Device Directive]]></category>
		<category><![CDATA[EU AIMDD]]></category>
		<category><![CDATA[EU IVD]]></category>
		<category><![CDATA[EU IVDD]]></category>
		<category><![CDATA[EU MDD]]></category>
		<category><![CDATA[EU Notified Bodies]]></category>
		<category><![CDATA[EU Notified Body]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[faq document]]></category>
		<category><![CDATA[IEC 62304]]></category>
		<category><![CDATA[implantable medical device]]></category>
		<category><![CDATA[industry manufacturers]]></category>
		<category><![CDATA[invitation letter]]></category>
		<category><![CDATA[IVD]]></category>
		<category><![CDATA[IVD Directive]]></category>
		<category><![CDATA[IVDD]]></category>
		<category><![CDATA[life cycle]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[medical device software]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[NB-MED]]></category>
		<category><![CDATA[NBRG]]></category>
		<category><![CDATA[Notified Bodies]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Q&A]]></category>
		<category><![CDATA[Software]]></category>
		<category><![CDATA[software life cycle]]></category>
		<category><![CDATA[SOUP]]></category>
		<category><![CDATA[standards developers]]></category>
		<category><![CDATA[V1.0]]></category>
		<category><![CDATA[Vers 1.0]]></category>
		<category><![CDATA[version v1]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3249</guid>

					<description><![CDATA[18 April 2013 – The NB-MED EN62304:2006 issues team released their first official version (V1.0) dated 5 April 2013 of this importnat implementation document in regards to EN 62304 with respect to the Medical Device Directive 93/42/EEC on the NB-MED website.  EN]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">18 April 2013 – The NB-MED EN62304:2006 issues team released their <strong><a href="http://www.eisnersafety.com/wp-content/uploads/2013/04/FAQ_62304_Ver_1.0_5Apr2013.pdf" target="_blank" rel="noopener noreferrer">first official version (V1.0) dated 5 April 2013 of this importnat implementation document in regards to EN 62304 with respect to the Medical Device Directive 93/42/EEC</a></strong> on the NB-MED website.  EN 62304 is the standard for MEDICAL DEVICE software – Software life-cycle processes. The document is intended to cover all three of the EU Medical Devices Directives which also include the Active Implantable Medical Device Directive 90/385/EC and the In-Vitro Diagnostic Directive 98/79/EC (refer to Q &amp; A 2.1.1).  An initial request for input from industry, notified bodies, consultants, and other stakeholders was sent out back in May 2012.  They were hoping to get the document released by September 2012 but with so much response to the request it took another 6 months to complete this first release of the document.  </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><span id="more-3249"></span>I (as a medical device consultant, US TAG member of IEC SC 62A &amp; 62D &amp; Convener of SC62D JWG9 {IEC/ISO/AAMI/CENELEC 80601-2-58} and a past Notified Body Auditor) am really pleased to see the extremely hard work that has gone into this document and also in the value that it will pass on to all the stakeholders.  There are many stakeholders that were involved in this process including Notified Bodies, NB-MED EN 62304:2006 issues team (Thank you for your hard work.), NB-MED, COCIR (European Coordination Committee of the Radiological, Electromedical and Healthcare IT Industry), Manufacturers, OEMs, Standards Developers for EN &amp; IEC &amp; other national standards bodies, Test Houses, Consultants, other countries regulatory bodies (i.e. FDA, Health Canada, etc.) and more.  By use of so many different stakeholders that submitted some of these and other questions this document has a much more consistent view on the implementation issues with the complexity of the topic of medical device software.  </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">This document is good for learning about your specific implementation issue(s) or if you have the time I would highly recommend reading the whole document, as this will help you understand the intricacies of some of the situations of implementing EN 62304 with respect to the Medical Devices Directives (I’m sure there are more issues but a good portion have been captured by this first version).  I believe this document would be of great help to implement similar guidance documents for many other national medical device regulatory agencies around the world for IEC 62304:2006 (or their national version of the standard).</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">The <strong>Table of Contents</strong> <span style="text-decoration: underline;">gives a good glimpse into the realm of the issues covered</span> in this document and covers the following topics.  I also provide a <span style="text-decoration: underline;">further glimpse into the document by summarizing some of the specific issues within those sections (these are the indents furthest to the right)</span>:</span></p>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Introduction (background of the purpose, rationale, the main team members, and how to provide more feedback on the document)</strong></span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Abbreviations (Section 1)</strong></span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Questions and Answers (Section 2 – Heading of sections 2.1 – 2.7)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Scope of EN 62304 (Section 2.1)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Goes into various different scenarios and discusses the implication and implementation issues around these scenarios: such as SAAS, Embedded software including FPGA’s (a hotly contested issue) with single chip computers, Hardware Description Languages specifying FPGAs, Stand alone software, Medical apps, Excel macros, Open &amp; closed systems, Internet or cloud based, Server based systems, Network devices.  In addition to this list of scenarios this section also goes into questions about certification; is Validation included in this standard &amp; if not where does it get covered; what are the expectation of the Notified Bodies with regard to the standard; can you use only part of the standard; why do class A software to EN 62304; what is IEC 82304 about (software only products); among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Placing Software as Medical Device on the Market (Section 2.2)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Explain ‘placing medical device (in this case software or software {s/w} as part of a system) on the market’ in EU if EN 62304 is sufficient, by itself to do this; can I change my intended use and avoid these EU guidelines and regulations; Conformity Assessment routes of the MDD; other countries acceptance / requirement of the standard; can you sign-off on documents electronically; classification of software as a MEDICAL DEVICE; how do Notified Bodies (NB’s) confirm compliance to the standard; among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Life-cycle Processes (Section 2.3)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">If s/w development is an outsourced activity what does NB expect; does this std have an equivalent expectation to requirements such as those addressed in FDA Part 11 (Electronic Records &amp; Signatures) in the US; details on the review process at the end of each iteration when updated versions are available during the design and development of the software; does the std require a specific development process; how split up the requirements/responsibilities of the std between the manufacturer and s/w sub-contractor; how do the maintenance activities in the std relate to ISO 20000/ITIL; what are the artifacts (documents) required by EN 62304; at what level does the Problem Resolution Process apply; does software refactoring require a formal change request; what to include in the Technical File to show compliance with EN 62304; how can agile processes be EN 62304 compliant; among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Risk Assessment and Risk Management (Section 2.4)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">How deal with risk control measures; when &amp; why can the safety class of a s/w SYSTEM be reduced; how use ISO 14971 with EN 62304; explain Hazard, Cause, Sequence of Events in the context of software; when should we expect additional Software Hazard Analysis guidance within EN 62304; among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Classification and Segregation (Section 2.5)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">What is segregation and how do I prove effective; use of a specific class(es) of s/w using COTS (commercial off-the-shelf) what criteria used; how does severity under intended use relate to s/w safety class; is s/w class optional; can you downgrade the classification of the system without a fully hardware protective system; does the compiler need to be classified under EN 62304; how are development platforms &amp; tools related to s/w safety class; relation between Risk Analysis at System level &amp; S/W Safety Classes; explain how the 3 safety classification in the std differ from the FDA’s 3 levels; correlate IEC 61508 SIL levels to EN 62304 safety classifications; s/w classification is a real issue with big implications; among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Specifications, testing and tools (Section 2.6)</strong><strong></strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">I’m a manufacturer of medical devices &#8211; how do I document my requirements and tests; web-based medical s/w – does the std have specific requirements related to digital cert’s, (http or https) server requirements; in regard to the std how deal with risk analysis and functional specs; appropriate level of granularity of requirements as design input, design description; which (if any) of the tracing requirements are meant to be bi-directional; questions around deployment of the s/w; what is required of open source code from the std; among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>SOUP (Software of Unknown Provenance) and Legacy Software (Section 2.7)</strong><strong></strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">How assess &amp; qualify suppliers of SOUP s/w, when the s/w hasn’t been developed for incorporating into a medical device; what testing &amp; documentation does EN 62304 require for SOUP to meet the std; s/w that is either stand-alone or embedded which was designed prior to publication of EN 62304 but still being placed on the market (legacy product) – what needs to be done; if legacy s/w needs significant change, what processes &amp; documents are required to achieve &amp;/or maintain compliance with EN 62304 and when are changes considered significant;</span></li>
</ul>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>References (No Section Number – just after Section 2.7)</strong></span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Software Problem Resolution Process (Annex 1)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Helpful diagram &#8211; There are several entry points to the problem resolution process, both during development and maintenance of the software (refer to question 2.3.12).</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>SOUP selection, assessment &amp; qualification (Annex 2)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Flowchart &amp; text to explain an example</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Traceability (Annex 3)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">The 3 flowcharts show an overview of the dependencies which need to be traced according to EN 62304 for all 3 classes &#8211; refer to note in bottom left corner of page to know which class the flowcharts apply to (refer to question 2.6.7).<strong></strong></span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Position paper on direct diagnosis (COCIR, 2011) (Annex 4)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">As the different stakeholders may interpret this term differently, COCIR and EUROM VI wanted to share their understanding of the term “direct diagnosis”. (Refer to question 2.5.13)</span></li>
</ul>
</ul>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Click on the weblink to see the <a href="http://www.eisnersafety.com/wp-content/uploads/2012/05/invitation-letter-FAQ-62304-final-copy.pdf" target="_blank" rel="noopener noreferrer"><strong>initial request for questions </strong></a>that we posted on our website 26 May 2012.  To see the posting please go to <strong><a href="http://www.eisnersafety.com/do-you-know-how-to-use-en62304-med-dvc-sw-life-cycle-as-implemented-under-themdd-aimdd-doc/">http://www.eisnersafety.com/do-you-know-how-to-use-en62304-med-dvc-sw-life-cycle-as-implemented-under-themdd-aimdd-doc/</a></strong></span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Do you know how to use EN62304 (med dvc s/w life-cycle) as implemented under the EU MDD &#038; AIMDD?</title>
		<link>https://eisnersafety.com/2012/05/26/do-you-know-how-to-use-en62304-med-dvc-sw-life-cycle-as-implemented-under-themdd-aimdd-doc/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=do-you-know-how-to-use-en62304-med-dvc-sw-life-cycle-as-implemented-under-themdd-aimdd-doc</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Sat, 26 May 2012 05:48:53 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[62304]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[CE Mark]]></category>
		<category><![CDATA[COCIR]]></category>
		<category><![CDATA[EN]]></category>
		<category><![CDATA[en 60601]]></category>
		<category><![CDATA[EN 62304]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[EU Notified Bodies]]></category>
		<category><![CDATA[EU Notified Body]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[faq document]]></category>
		<category><![CDATA[IEC 62304]]></category>
		<category><![CDATA[invitation letter]]></category>
		<category><![CDATA[life cycle]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[Notified Bodies]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Q&A]]></category>
		<category><![CDATA[request document]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=2543</guid>

					<description><![CDATA[Recently it was concluded jointly by industry and European Notified Bodies that there is less clarity in the use of EN 62304 than is desirable. As a consequence, it was decided to start a project to develop a paper with]]></description>
										<content:encoded><![CDATA[<p>Recently it was concluded jointly by industry and European Notified Bodies that there is less clarity in the use of EN 62304 than is desirable. As a consequence, it was decided to start a project to develop a paper with Frequently Asked Questions (FAQ) and answers on the use of EN 62304, especially in the context of CE-marking. This project is a joint undertaking with COCIR (EU Medical Device Industry Trade association) and the EU Notified Bodies for medical devices.</p>
<p>A request for practical questions and issues has just been launched and the <a href="http://www.eisnersafety.com/wp-content/uploads/2012/05/invitation-letter-FAQ-62304-final-copy.pdf">invitation letter for FAQ on EN62304</a> (a short 2 page document) and publication of the FAQ is expected by end of September 2012.  The request document is asking for your questions and any proposed answers (if you have those too) to be submitted by the end of May 2012 so you better hop on the bandwagon and get those off to the e-mail address of <a href="mailto:&#70;&#65;&#81;6&#50;&#51;&#48;&#52;&#64;&#86;DE.com">&#70;A&#81;&#54;&#50;304&#64;&#86;&#68;E&#46;com</a>.  I think some of these dates may slip a little but that is not confirmed yet.  If I get confirmation of any changes in dates I will advise as soon as I can.</p>
<p>This may sound familiar as this is a similar process to the <a href="http://www.eisnersafety.com/nb-med-issues-v1_1-faq-on-implementation-of-en60601-1_2006-with-respect-to-mdd/">FAQ document that was issued in Jan/Feb of this year for the EN 60601-1, 3rd ed. Implementation FAQ document</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
