<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>93/42/EEC &#8211; Eisner Safety Consultants</title>
	<atom:link href="https://eisnersafety.com/tag/9342eec/feed/" rel="self" type="application/rss+xml" />
	<link>https://eisnersafety.com</link>
	<description>Regulatory &#38; Safety Experts for Global Medical Device Approvals</description>
	<lastBuildDate>Fri, 19 Apr 2013 02:51:26 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://eisnersafety.com/wp-content/uploads/2025/08/favicon-45x45.png</url>
	<title>93/42/EEC &#8211; Eisner Safety Consultants</title>
	<link>https://eisnersafety.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>NB-MED issues FAQ on Implementation of EN62304:2006 w.r.t. MDD, V1.0</title>
		<link>https://eisnersafety.com/2013/04/19/nb-med-issues-faq-on-implementation-of-en623042006-w-r-t-mdd-v1-0/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=nb-med-issues-faq-on-implementation-of-en623042006-w-r-t-mdd-v1-0</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Fri, 19 Apr 2013 02:51:26 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[62304]]></category>
		<category><![CDATA[90/385/EC]]></category>
		<category><![CDATA[93/42/EEC]]></category>
		<category><![CDATA[98/79/EC]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[CE Mark]]></category>
		<category><![CDATA[CENELEC]]></category>
		<category><![CDATA[COCIR]]></category>
		<category><![CDATA[electromedical]]></category>
		<category><![CDATA[EN]]></category>
		<category><![CDATA[en 60601]]></category>
		<category><![CDATA[EN 62304]]></category>
		<category><![CDATA[EN 62304:2006]]></category>
		<category><![CDATA[EN62304]]></category>
		<category><![CDATA[EN62304:2006]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[EU Active Implantable Medical Device Directive]]></category>
		<category><![CDATA[EU AIMDD]]></category>
		<category><![CDATA[EU IVD]]></category>
		<category><![CDATA[EU IVDD]]></category>
		<category><![CDATA[EU MDD]]></category>
		<category><![CDATA[EU Notified Bodies]]></category>
		<category><![CDATA[EU Notified Body]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[faq document]]></category>
		<category><![CDATA[IEC 62304]]></category>
		<category><![CDATA[implantable medical device]]></category>
		<category><![CDATA[industry manufacturers]]></category>
		<category><![CDATA[invitation letter]]></category>
		<category><![CDATA[IVD]]></category>
		<category><![CDATA[IVD Directive]]></category>
		<category><![CDATA[IVDD]]></category>
		<category><![CDATA[life cycle]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[medical device software]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[NB-MED]]></category>
		<category><![CDATA[NBRG]]></category>
		<category><![CDATA[Notified Bodies]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Q&A]]></category>
		<category><![CDATA[Software]]></category>
		<category><![CDATA[software life cycle]]></category>
		<category><![CDATA[SOUP]]></category>
		<category><![CDATA[standards developers]]></category>
		<category><![CDATA[V1.0]]></category>
		<category><![CDATA[Vers 1.0]]></category>
		<category><![CDATA[version v1]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3249</guid>

					<description><![CDATA[18 April 2013 – The NB-MED EN62304:2006 issues team released their first official version (V1.0) dated 5 April 2013 of this importnat implementation document in regards to EN 62304 with respect to the Medical Device Directive 93/42/EEC on the NB-MED website.  EN]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">18 April 2013 – The NB-MED EN62304:2006 issues team released their <strong><a href="http://www.eisnersafety.com/wp-content/uploads/2013/04/FAQ_62304_Ver_1.0_5Apr2013.pdf" target="_blank" rel="noopener noreferrer">first official version (V1.0) dated 5 April 2013 of this importnat implementation document in regards to EN 62304 with respect to the Medical Device Directive 93/42/EEC</a></strong> on the NB-MED website.  EN 62304 is the standard for MEDICAL DEVICE software – Software life-cycle processes. The document is intended to cover all three of the EU Medical Devices Directives which also include the Active Implantable Medical Device Directive 90/385/EC and the In-Vitro Diagnostic Directive 98/79/EC (refer to Q &amp; A 2.1.1).  An initial request for input from industry, notified bodies, consultants, and other stakeholders was sent out back in May 2012.  They were hoping to get the document released by September 2012 but with so much response to the request it took another 6 months to complete this first release of the document.  </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><span id="more-3249"></span>I (as a medical device consultant, US TAG member of IEC SC 62A &amp; 62D &amp; Convener of SC62D JWG9 {IEC/ISO/AAMI/CENELEC 80601-2-58} and a past Notified Body Auditor) am really pleased to see the extremely hard work that has gone into this document and also in the value that it will pass on to all the stakeholders.  There are many stakeholders that were involved in this process including Notified Bodies, NB-MED EN 62304:2006 issues team (Thank you for your hard work.), NB-MED, COCIR (European Coordination Committee of the Radiological, Electromedical and Healthcare IT Industry), Manufacturers, OEMs, Standards Developers for EN &amp; IEC &amp; other national standards bodies, Test Houses, Consultants, other countries regulatory bodies (i.e. FDA, Health Canada, etc.) and more.  By use of so many different stakeholders that submitted some of these and other questions this document has a much more consistent view on the implementation issues with the complexity of the topic of medical device software.  </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">This document is good for learning about your specific implementation issue(s) or if you have the time I would highly recommend reading the whole document, as this will help you understand the intricacies of some of the situations of implementing EN 62304 with respect to the Medical Devices Directives (I’m sure there are more issues but a good portion have been captured by this first version).  I believe this document would be of great help to implement similar guidance documents for many other national medical device regulatory agencies around the world for IEC 62304:2006 (or their national version of the standard).</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">The <strong>Table of Contents</strong> <span style="text-decoration: underline;">gives a good glimpse into the realm of the issues covered</span> in this document and covers the following topics.  I also provide a <span style="text-decoration: underline;">further glimpse into the document by summarizing some of the specific issues within those sections (these are the indents furthest to the right)</span>:</span></p>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Introduction (background of the purpose, rationale, the main team members, and how to provide more feedback on the document)</strong></span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Abbreviations (Section 1)</strong></span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Questions and Answers (Section 2 – Heading of sections 2.1 – 2.7)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Scope of EN 62304 (Section 2.1)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Goes into various different scenarios and discusses the implication and implementation issues around these scenarios: such as SAAS, Embedded software including FPGA’s (a hotly contested issue) with single chip computers, Hardware Description Languages specifying FPGAs, Stand alone software, Medical apps, Excel macros, Open &amp; closed systems, Internet or cloud based, Server based systems, Network devices.  In addition to this list of scenarios this section also goes into questions about certification; is Validation included in this standard &amp; if not where does it get covered; what are the expectation of the Notified Bodies with regard to the standard; can you use only part of the standard; why do class A software to EN 62304; what is IEC 82304 about (software only products); among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Placing Software as Medical Device on the Market (Section 2.2)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Explain ‘placing medical device (in this case software or software {s/w} as part of a system) on the market’ in EU if EN 62304 is sufficient, by itself to do this; can I change my intended use and avoid these EU guidelines and regulations; Conformity Assessment routes of the MDD; other countries acceptance / requirement of the standard; can you sign-off on documents electronically; classification of software as a MEDICAL DEVICE; how do Notified Bodies (NB’s) confirm compliance to the standard; among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Life-cycle Processes (Section 2.3)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">If s/w development is an outsourced activity what does NB expect; does this std have an equivalent expectation to requirements such as those addressed in FDA Part 11 (Electronic Records &amp; Signatures) in the US; details on the review process at the end of each iteration when updated versions are available during the design and development of the software; does the std require a specific development process; how split up the requirements/responsibilities of the std between the manufacturer and s/w sub-contractor; how do the maintenance activities in the std relate to ISO 20000/ITIL; what are the artifacts (documents) required by EN 62304; at what level does the Problem Resolution Process apply; does software refactoring require a formal change request; what to include in the Technical File to show compliance with EN 62304; how can agile processes be EN 62304 compliant; among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Risk Assessment and Risk Management (Section 2.4)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">How deal with risk control measures; when &amp; why can the safety class of a s/w SYSTEM be reduced; how use ISO 14971 with EN 62304; explain Hazard, Cause, Sequence of Events in the context of software; when should we expect additional Software Hazard Analysis guidance within EN 62304; among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Classification and Segregation (Section 2.5)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">What is segregation and how do I prove effective; use of a specific class(es) of s/w using COTS (commercial off-the-shelf) what criteria used; how does severity under intended use relate to s/w safety class; is s/w class optional; can you downgrade the classification of the system without a fully hardware protective system; does the compiler need to be classified under EN 62304; how are development platforms &amp; tools related to s/w safety class; relation between Risk Analysis at System level &amp; S/W Safety Classes; explain how the 3 safety classification in the std differ from the FDA’s 3 levels; correlate IEC 61508 SIL levels to EN 62304 safety classifications; s/w classification is a real issue with big implications; among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Specifications, testing and tools (Section 2.6)</strong><strong></strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">I’m a manufacturer of medical devices &#8211; how do I document my requirements and tests; web-based medical s/w – does the std have specific requirements related to digital cert’s, (http or https) server requirements; in regard to the std how deal with risk analysis and functional specs; appropriate level of granularity of requirements as design input, design description; which (if any) of the tracing requirements are meant to be bi-directional; questions around deployment of the s/w; what is required of open source code from the std; among other questions.</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>SOUP (Software of Unknown Provenance) and Legacy Software (Section 2.7)</strong><strong></strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">How assess &amp; qualify suppliers of SOUP s/w, when the s/w hasn’t been developed for incorporating into a medical device; what testing &amp; documentation does EN 62304 require for SOUP to meet the std; s/w that is either stand-alone or embedded which was designed prior to publication of EN 62304 but still being placed on the market (legacy product) – what needs to be done; if legacy s/w needs significant change, what processes &amp; documents are required to achieve &amp;/or maintain compliance with EN 62304 and when are changes considered significant;</span></li>
</ul>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>References (No Section Number – just after Section 2.7)</strong></span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Software Problem Resolution Process (Annex 1)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Helpful diagram &#8211; There are several entry points to the problem resolution process, both during development and maintenance of the software (refer to question 2.3.12).</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>SOUP selection, assessment &amp; qualification (Annex 2)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Flowchart &amp; text to explain an example</span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Traceability (Annex 3)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">The 3 flowcharts show an overview of the dependencies which need to be traced according to EN 62304 for all 3 classes &#8211; refer to note in bottom left corner of page to know which class the flowcharts apply to (refer to question 2.6.7).<strong></strong></span></li>
</ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>Position paper on direct diagnosis (COCIR, 2011) (Annex 4)</strong></span></li>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">As the different stakeholders may interpret this term differently, COCIR and EUROM VI wanted to share their understanding of the term “direct diagnosis”. (Refer to question 2.5.13)</span></li>
</ul>
</ul>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Click on the weblink to see the <a href="http://www.eisnersafety.com/wp-content/uploads/2012/05/invitation-letter-FAQ-62304-final-copy.pdf" target="_blank" rel="noopener noreferrer"><strong>initial request for questions </strong></a>that we posted on our website 26 May 2012.  To see the posting please go to <strong><a href="http://www.eisnersafety.com/do-you-know-how-to-use-en62304-med-dvc-sw-life-cycle-as-implemented-under-themdd-aimdd-doc/">http://www.eisnersafety.com/do-you-know-how-to-use-en62304-med-dvc-sw-life-cycle-as-implemented-under-themdd-aimdd-doc/</a></strong></span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>EU Team-NB adopted V3.0 Code of Conduct &#8211; Align to Recent Proposed Regulations</title>
		<link>https://eisnersafety.com/2012/11/13/eu-team-nb-issues-a-code-of-conduct-some-have-signed/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=eu-team-nb-issues-a-code-of-conduct-some-have-signed</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Tue, 13 Nov 2012 06:20:40 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[2007/47/EC]]></category>
		<category><![CDATA[90/385/EEC]]></category>
		<category><![CDATA[93/42/EEC]]></category>
		<category><![CDATA[98/79/EC]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[CENELEC]]></category>
		<category><![CDATA[Class I]]></category>
		<category><![CDATA[Class III]]></category>
		<category><![CDATA[Code of Conduct for Notified Bodies]]></category>
		<category><![CDATA[Design Dossier Reviews]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[EU Active Implantable Medical Device Directive]]></category>
		<category><![CDATA[EU Medical Device Regulation]]></category>
		<category><![CDATA[EU Notified Bodies]]></category>
		<category><![CDATA[EU Notified Body]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[implantable medical devices]]></category>
		<category><![CDATA[IVD]]></category>
		<category><![CDATA[IVD Directive]]></category>
		<category><![CDATA[IVDD]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[MDD Amendment]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[medical device directives]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[medical device manufacturers]]></category>
		<category><![CDATA[Medical Device Regulations]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[medical devices directive]]></category>
		<category><![CDATA[medical directive]]></category>
		<category><![CDATA[Minimum time for Notified Body assessments]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[Rules for Certification Decisions]]></category>
		<category><![CDATA[Rules for subcontracting]]></category>
		<category><![CDATA[Sampling of Class IIa & IIb Technical Files]]></category>
		<category><![CDATA[Sampling of Technical Files]]></category>
		<category><![CDATA[TEAM-NB]]></category>
		<category><![CDATA[Unannounced Audits]]></category>
		<category><![CDATA[unannounced inspections]]></category>
		<category><![CDATA[unannounced visits]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=2857</guid>

					<description><![CDATA[On 10 Oct 2012 The European Association for Medical devices of Notified Bodies (better known as Team-NB) issued a press release on the adoption of Version 3.0 of the Code of Conduct (CoC) for Notified Bodies under Directives 90/385/EEC (Active]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif;">On 10 Oct 2012 <strong><a href="http://www.team-nb.org/" target="_blank" rel="noopener noreferrer">The European Association for Medical devices of Notified Bodies</a></strong> (better known as <strong><a href="http://www.team-nb.org/" target="_blank" rel="noopener noreferrer">Team-NB</a></strong>) issued a <strong><a href="http://www.eisnersafety.com/wp-content/uploads/2012/11/Team-NB-Press-release-COC1.pdf" target="_blank" rel="noopener noreferrer">press release on the adoption of Version 3.0 of the Code of Conduct (CoC) for Notified Bodies</a></strong> under Directives 90/385/EEC (Active Implantable Medical Devices Directive), 93/42/EEC (Medical Devices Directive), and 98/79/EC (In-Vitro Diagnostic Directive) that is focusing on the <strong><a title="White Paper on Propposed New EU Medical Device Regulations" href="http://www.eisnersafety.com/white-paper-on-proposed-new-eu-medical-device-regulations/" target="_blank" rel="noopener noreferrer">recently proposed Medical Device Regulations</a></strong>.  </span></p>
<p><span style="font-family: arial, helvetica, sans-serif;"><span id="more-2857"></span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: arial, helvetica, sans-serif;">Team-NB is a voluntary organization of Medical Device Notified Bodies (doesn&#8217;t represent all EU NB&#8217;s under the 3 Medical Device Directives) and as of 12 Nov 2012 there are now 35 members.  During the 9 Oct 2012 Assembly in addition to the adoption of the CoC three (3) new members were unanimously added (LGA InterCert GmbH &#8211; Nurnberg Deutschland, UDEM &#8211; Ankara Turkey, and ALBERK QA TECKNIC &#8211; Istanbul Turkey).</span></p>
<p><span style="font-family: arial, helvetica, sans-serif;">The <strong><a href="http://www.eisnersafety.com/wp-content/uploads/2012/11/Code_of_Conduct_Medical_Notified_Bodies_v3-0.pdf" target="_blank" rel="noopener noreferrer">Version 3.0 Code of Conduct for Notified Bodies under Directives 90/385/EEC, 93/42/EEC, &amp; 98/79/EC</a></strong> is a very thorough document which is 31 pages long and includes the Unannounced Inspections (or Unannounced Audits of Medical Device Manufacturers that are Certified under the applicable Medical Directive) which comes from the <strong><a title="White Paper on Propposed New EU Medical Device Regulations" href="http://www.eisnersafety.com/white-paper-on-proposed-new-eu-medical-device-regulations/" target="_blank" rel="noopener noreferrer">recently proposed Medical Device Regulations</a></strong>.  As of the <strong><a href="http://www.eisnersafety.com/wp-content/uploads/2012/11/TEAM-NB-Member-List-COC-signed-by-14-NBs-201210301.doc" target="_blank" rel="noopener noreferrer">30 October 2012 News Release 14 Notified Bodies had signed the V3.0 CoC</a></strong> and 2 additional NBs (LNE/G-MED &amp; DQS) signed prior to 12 Nov 2012.  It is anticipated that more NBs will sign in the near future as they adopt the policies covered within the V3.0 CoC which shows their commitment to improve the implementation of the EU CE marking certification of medical devices through clarified organizational criteria, management of competence and assessment practices.  The major topics in the document are:</span></p>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif;">Implementation, enforcement and monitoring of the Code of Conduct </span></li>
<li><span style="font-family: arial, helvetica, sans-serif;">Qualification and Assignment of Notified Body Assessment Personnel </span></li>
<li><span style="font-family: arial, helvetica, sans-serif;">Minimum time for Notified Body assessments </span></li>
<li><span style="font-family: arial, helvetica, sans-serif;">Unannounced visits </span></li>
<li><span style="font-family: arial, helvetica, sans-serif;">Sampling of class IIa and IIb technical files </span></li>
<li><span style="font-family: arial, helvetica, sans-serif;">Design Dossier Reviews </span></li>
<li><span style="font-family: arial, helvetica, sans-serif;">Rules for subcontracting </span></li>
<li><span style="font-family: arial, helvetica, sans-serif;">Rules for Certification Decisions </span></li>
</ul>
<p><span style="font-family: arial, helvetica, sans-serif;">Further revisions will be made to be in line with the new developments of the European legislation.</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RoHS Recast Implications to EU Med &#038; IVD Devices</title>
		<link>https://eisnersafety.com/2011/08/31/rohs-recast-implications-to-eu-med-ivd-devices/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=rohs-recast-implications-to-eu-med-ivd-devices</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Wed, 31 Aug 2011 20:24:58 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[22 July 2014]]></category>
		<category><![CDATA[22 July 2016]]></category>
		<category><![CDATA[90/385/EEC]]></category>
		<category><![CDATA[93/42/EEC]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[Cadmium]]></category>
		<category><![CDATA[CE Mark]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[EU RoHS]]></category>
		<category><![CDATA[Hexavalent Chromium]]></category>
		<category><![CDATA[IVD]]></category>
		<category><![CDATA[IVDD]]></category>
		<category><![CDATA[Lead]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[Mercury]]></category>
		<category><![CDATA[PBB]]></category>
		<category><![CDATA[PBDE]]></category>
		<category><![CDATA[Polybrominated biphenyls]]></category>
		<category><![CDATA[Polybrominated diphenyl ethers]]></category>
		<category><![CDATA[Restriction of Hazardous Substances]]></category>
		<category><![CDATA[RoHS]]></category>
		<category><![CDATA[RoHS 2]]></category>
		<category><![CDATA[Technical File]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=2208</guid>

					<description><![CDATA[The following is provided thx to one of Eisner Safety Consultants Associates, Christine Ruther: The recast of the Restriction of Hazardous Substances (RoHS) Directive has been released as 2011/65/EU.  You can read the directive at http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2011:174:0088:0110:EN:PDF.  With the exception of]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">The following is provided thx to one of Eisner Safety Consultants Associates, Christine Ruther:</span></span></p>
<p><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">The recast of the Restriction of Hazardous Substances (RoHS) Directive has been released as 2011/65/EU.  You can read the directive at <a href="http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2011:174:0088:0110:EN:PDF">http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2011:174:0088:0110:EN:PDF</a>.  With the exception of the items listed in Article 2.4, the RoHS Directive applies to all Electrical &amp; Electronic Equipment.</span></span></span></p>
<p><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">As an overview:</span></span></span></p>
<p style="padding-left: 30px; "><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">&#8211;   <strong><em>Scope:</em></strong></span></span></span></p>
<ul>
<li>
<ul>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"><strong><span style="color: #ff0000;">Medical devices</span></strong></span></span></span> (per 93/42/EEC) and <strong><span style="color: #ff0000;">IVD devices</span></strong> (per 90/385/EEC) are now <strong><span style="color: #ff0000;">included</span></strong>.  They are both part of the general group called “medical devices” in the directive.</li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Active implantable medical devices remain excluded from the requirements of the directive.</span></span></span></li>
</ul>
</li>
</ul>
<p style="padding-left: 30px; "><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">&#8211;   <strong><em>Limits:</em></strong> The maximum concentrations in homogenous materials are limited, by weight:</span></span></span></p>
<ul>
<li>
<ul>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Lead (0.1 %)</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Mercury (0.1 %)</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Cadmium (0.01 %)</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Hexavalent chromium (0.1 %)</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Polybrominated biphenyls (PBB) (0.1 %)</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Polybrominated diphenyl ethers (PBDE) (0.1 %)</span></span></span></li>
</ul>
</li>
</ul>
<p style="padding-left: 30px; "><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">&#8211;   <strong><em>Transition:</em></strong> Devices must bear a CE mark and have a declaration of conformity for the RoHS Directive from</span></span></span></p>
<ul>
<li>
<ul>
<li><strong><span style="text-decoration: underline;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"><span style="color: #ff0000;">22 July 2014 for Medical Devices</span></span></span></span></span></strong>.</li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"><strong><span style="text-decoration: underline;"><span style="color: #ff0000;">22 July 2016 for In-Vitro Diagnostic Medical Devices</span></span></strong></span></span></span>.</li>
</ul>
</li>
</ul>
<p style="padding-left: 60px; "><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">NOTE:  A single CE mark and declaration are acceptable.  (You will need to explain the dual meaning of the CE mark in the instructions for use and clarify that, if used, the Notified Body number only applies to the MDD or IVDD related issues.)</span></span></span></p>
<p style="padding-left: 30px; "><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">&#8211;   <strong><em>Exemptions:</em></strong></span></span></span></p>
<ul>
<li>
<ul>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Cables and spare parts needed for the repair or reuse of devices may continue to be distributed for devices placed on the market prior to the transition date.</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Exemptions available to all devices are listed in Annex III.  Specific exemptions for medical devices are listed in Annex IV.</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Exemptions for medical devices will be valid for up to 7 years.</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Requests for exemptions:</span></span></span></li>
</ul>
</li>
</ul>
<ul>
<li>
<ul>
<li>
<ul>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Will be filed with the Commission and include all information listed in Annex V.  Most notably, the <strong>request must include an analysis of possible alternative substances, materials or designs</strong>.</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Renewals must be requested at least 18 months before the existing exemption expires.</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Applications for exemptions will be accepted for medical devices even before the RoHS Directive is fully transposed (2JAN2013) if an overseeing Notified Body certifies that the safety of potential substitute has a clear negative socioeconomic, health <span style="text-decoration: underline;">and</span> consumer safety impacts.</span></span></span></li>
</ul>
</li>
</ul>
</li>
</ul>
<p style="padding-left: 30px; "><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">&#8211;   <strong><em>Labeling:</em></strong> The labeling requirements are likely already addressed by MDD or IVDD requirements.  However, you should review the requirements in Articles 7.g, 7.h9.d and 10.a to confirm.</span></span></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; "> &#8211;   <strong><em>Record Retention:</em></strong></span></p>
<ul style="padding-left: 30px; ">
<li>
<ul>
<li style="padding-left: 30px; "><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Records must be <span style="color: #ff0000;"><strong>retained for 10 years</strong> </span>after a device is placed on the market.  Note that this may be longer than required by the MDD or IVDD.</span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Records to retain include:</span></span></span>
<ul>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Technical documentation confirming compliance with the RoHS Directive and a register of non-conforming product and product recalls,</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">List of any economic operator (manufacturer, authorized representative, importer, distributor) who has supplied you with electrical or electronic equipment, and</span></span></span></li>
<li><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">List of  any economic operator to whom you have supplied any electrical or electronic equipment.</span></span></span></li>
</ul>
</li>
</ul>
</li>
</ul>
<p style="padding-left: 30px; "><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">If you would like to see some additional information on some of the areas, in the future, that may be implemented refer to the  BSI article that is <a href="http://www.eisnersafety.com/recasted-rohs-directive-will-apply-to-med-dvcs-ivds/">posted on our website</a>.</span></span></p>
<p style="padding-left: 30px; "><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Our group (Eisner Safety Consultants) has worked with a select set of service providers that can obtain the CofC’s or the total composition information for each component and in turn the full product composition.  Please feel free to contact me, Leo Eisner (&#76;&#101;o&#64;&#69;i&#115;&#110;&#101;rs&#97;fet&#121;.&#99;o&#109;) if you have any questions on this subject and I would be more than happy to assist you.</span></span></p>
<p style="padding-left: 30px; "><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Please <a href="mailto:L&#101;&#111;&#64;E&#105;&#115;&#110;er&#83;&#97;&#102;e&#116;y&#46;co&#109;" target="_blank" rel="noopener noreferrer">contact us</a> if you have questions or concerns.</span></span></span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>COCIR Issues Flowchart to determine if Software = Med Dvc per MDD</title>
		<link>https://eisnersafety.com/2011/04/20/cocir-issues-flowchart-to-determine-if-software-med-dvc-per-mdd/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=cocir-issues-flowchart-to-determine-if-software-med-dvc-per-mdd</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Wed, 20 Apr 2011 18:42:40 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[93/42/EEC]]></category>
		<category><![CDATA[COCIR]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[MDD Amendment]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[Software]]></category>
		<category><![CDATA[Software Decision Diagram]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=2110</guid>

					<description><![CDATA[COCIR, the European industry association representing the radiological, electromedical and IT industries, issued (on 22 Nov 2010) a decision diagram to determine if software is considered a medical device per the Medical Device Directive (MDD) 93/42/EEC including the amendment.  The]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small;">COCIR, the European industry association representing the radiological, electromedical and IT industries, issued (on 22 Nov 2010) a </span><a title="COCIR Decision Diagram if Software per the MDD " href="http://www.cocir.org/uploads/documents/-48-cocir_medical_software_qualification_as_medical_device_-_22_nov_2010.pdf" target="_blank" rel="noopener noreferrer"><span style="font-size: small;">decision diagram</span></a><span style="font-size: small;"> to determine if software is considered a medical device per the Medical Device Directive (MDD) 93/42/EEC including the amendment.  The document includes a clear definition of what software includes, which is a wide range of items.  Refer to the footnotes for some details that refer back to the MDD.</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MDD Harmonized Stds List updated 18-JAN-11</title>
		<link>https://eisnersafety.com/2011/02/18/mdd-harmonized-stds-list-updated-18-jan-11/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=mdd-harmonized-stds-list-updated-18-jan-11</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Fri, 18 Feb 2011 23:07:30 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[93/42/EEC]]></category>
		<category><![CDATA[List of Harmonized Standards]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=2072</guid>

					<description><![CDATA[The latest update to the Harmonized List of Standards under the medical device directive (MDD) 93/42/EEC was issued on 18-JAN-11]]></description>
										<content:encoded><![CDATA[<p><span style="outline-width: 0px; outline-style: initial; outline-color: initial; font-weight: inherit; font-style: inherit; font-size: 13px; font-family: inherit; vertical-align: baseline; padding: 0px; margin: 0px; border: 0px initial initial;">The latest update to the <a title="Click here for the 18-JAN-2011 MDD Harmonized List of Stds" href="http://ht.ly/3YP0u" target="_blank" rel="noopener noreferrer">Harmonized List of Standards under the medical device directive (MDD)</a> 93/42/EEC was issued on 18-JAN-11</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>EU Interpretative Doc on Placing Med Dev&#8217;s on Mrkt</title>
		<link>https://eisnersafety.com/2010/12/01/eu-interpretative-doc-on-placing-med-devs-on-mrkt/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=eu-interpretative-doc-on-placing-med-devs-on-mrkt</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Wed, 01 Dec 2010 19:43:29 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[2007/47/EC]]></category>
		<category><![CDATA[90/385/EEC]]></category>
		<category><![CDATA[93/42/EEC]]></category>
		<category><![CDATA[98/79/EC]]></category>
		<category><![CDATA[98/8/EC]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[Emergency Medical Devices Environment]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[EU Interpretative Document]]></category>
		<category><![CDATA[In Vitro Diagnostic Directive]]></category>
		<category><![CDATA[IVD]]></category>
		<category><![CDATA[IVDD]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[MDD Amendment]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[Medical Implants]]></category>
		<category><![CDATA[Medical Systems]]></category>
		<category><![CDATA[Placing on the Market]]></category>
		<category><![CDATA[Placing on the Market of Medical Devices]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=1940</guid>

					<description><![CDATA[On 16 November 2010 this Interpretative Document was issued to explain what is considered Placing Medical Devices on the EU Market.  The document refers to all 3 medical device directives including the amendment 2007/47/EC.  The 3 medical device directives this]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small;"><span style="color: #333399;"><span style="font-family: arial, helvetica, sans-serif;">On 16 November 2010 this Interpretative Document was issued to explain what is considered Placing Medical Devices on the EU Market.  The document refers to all 3 medical device directives including the amendment 2007/47/EC.  The 3 medical device directives this applies to are Active Implantables Medical Devices </span></span></span><span style="line-height: normal;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">90/385/EEC, Medical Devices 93/42/EEC, and the InVitro Diagnostic Medical Devices 98/76/EC.  Additionally, the biocidal products directive </span></span></span></span></span></span></span><span style="line-height: normal; font-size: 12px;"><span style="font-size: small;"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">98/8/EC is also referenced in this document. </span></span></span></span></span></span></p>
<p><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">This document refers to the </span></span></span></span><span style="font-size: 13.2px;"><a href="http://www.eisnersafety.com/wp-content/uploads/2010/12/l_21820080813en00300047.pdf"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">EU Directive on accreditation and market surveillance relating to the marketing of products</span></span></span></span></a></span><span style="font-size: 13.2px;"><span style="line-height: normal; color: #1a1a18;"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"> which is EC/</span></span></span></span></span><span style="line-height: normal; color: #1a1a18;"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">765/2008.  EC/765/2008 is relied on for the term &#8220;making available&#8217;.</span></span></span></span></span></span></p>
<p><span style="line-height: normal; font-size: 12px;"><span style="font-size: small;"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">The interpretative document may be viewed by clicking </span></span></span></span></span></span><span style="font-size: 13.2px;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"><a href="http://www.eisnersafety.com/wp-content/uploads/2010/12/placing_on_the_market_en.pdf"><span style="font-size: small;"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">EU Interpretative Document &#8211; Placing Medical Devices on the Market</span></span></span></span></span></a><span style="font-size: small;"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">.</span></span></span></span></span></span></span></span></p>
<p><span style="font-size: 13.2px;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"><span style="font-size: small;"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">To see a list of the current EU Medical Device Directives Interpretative Documents you can go to the </span></span></span></span></span><a title="EUROPA web page for Med Dvcs Interpretative Documents" href="http://ec.europa.eu/consumers/sectors/medical-devices/documents/interpretative-documents/index_en.htm" target="_blank" rel="noopener noreferrer"><span style="font-size: small;"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">EUROPA webpage that has the Medical Device Directives Interpretative Documents</span></span></span></span></span></a></span></span></span><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="color: #333399;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">.</span></span></span></span></span></span></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>