<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ANSI/AAMI HA60601-1-11:2011 &#8211; Eisner Safety Consultants</title>
	<atom:link href="https://eisnersafety.com/tag/ansiaami-ha60601-1-112011/feed/" rel="self" type="application/rss+xml" />
	<link>https://eisnersafety.com</link>
	<description>Regulatory &#38; Safety Experts for Global Medical Device Approvals</description>
	<lastBuildDate>Sun, 31 May 2015 18:00:57 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://eisnersafety.com/wp-content/uploads/2025/08/favicon-45x45.png</url>
	<title>ANSI/AAMI HA60601-1-11:2011 &#8211; Eisner Safety Consultants</title>
	<link>https://eisnersafety.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>IEC TR 60601-4-3:2015 Guidance &#038; interpretation of IEC 60601-1, 3rd ed. Published</title>
		<link>https://eisnersafety.com/2015/05/31/iec-tr-60601-4-32015-guidance-interpretation-of-iec-60601-1-3rd-ed-published/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=iec-tr-60601-4-32015-guidance-interpretation-of-iec-60601-1-3rd-ed-published</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Sun, 31 May 2015 18:00:57 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[60601-1-11]]></category>
		<category><![CDATA[60601-4-3]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[AAMI ES60601-1/C1]]></category>
		<category><![CDATA[Amendment 1]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11:2011]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11:2011 (IEC 60601-1-11:2010]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[FDA Guidance]]></category>
		<category><![CDATA[HA 60601-1-11]]></category>
		<category><![CDATA[HA60601-1-11]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[IEC 60601-1-11]]></category>
		<category><![CDATA[IEC 60601-4-3]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[IEC60601-4-3]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=4240</guid>

					<description><![CDATA[IEC TR 60601-4-3:2015 Guidance &#38; interpretation of IEC 60601-1, 3rd ed. Published This post discusses the recently published Guidance IEC TR 60601-4-3:2015 that issues interpretations of IEC 60601-1, 3rd ed. and edition 3.1. The technical report tiled IEC TR 60601-4-3:2015]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="http://www.eisnersafety.com/wp-content/uploads/2015/05/IEC60601-4-3_2015web.png"><img fetchpriority="high" decoding="async" class="alignleft size-medium wp-image-4242" style="border: 1px solid black; margin: 3px;" title="IEC60601-4-3_2015(web)" src="http://www.eisnersafety.com/wp-content/uploads/2015/05/IEC60601-4-3_2015web-219x300.png" alt="" width="219" height="300" /></a>IEC TR 60601-4-3:2015 Guidance &amp; interpretation of IEC 60601-1, 3<sup>rd</sup> ed. Published</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">This post discusses the recently published Guidance IEC TR 60601-4-3:2015 that issues interpretations of IEC 60601-1, 3rd ed. and edition 3.1.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The technical report tiled IEC TR 60601-4-3:2015 Guidance &amp; interpretation – Considerations of unaddressed safety aspects in the 3<sup>rd</sup> ed of IEC 60601-1 &amp; proposal for new requirements was released April 2015.  It deals with recommendations and interpretations of the IEC 60601-1, 3<sup>rd</sup> ed. and edition 3.1 (or 3<sup>rd</sup> ed. + A1).  IEC Subcommittee (SC) 62A established a process under which Working Group (WG) 14 would develop recommendations regarding problems of interpretation or application of IEC 60601-1.  I am a member of this WG.  Many of the WG14 experts are employed by test laboratories and manufacturers and have many years experience applying IEC 60601-1 to MEDICAL ELECTRICAL EQUIPMENT.  The one thing to be crystal clear about is in the INTRODUCTION of the document it says:</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“While the National Committee members of SC 62A nominate these experts, their recommendations were not to be formally adopted through any official voting procedure. To reinforce this process, the Subcommittee specifically directed that the following note appear on every page of the resulting informational circular:</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong>IMPORTANT NOTE:</strong> Per the 62A decision at Sydney…, the 62A Secretary is circulating this recommendation,…regarding problems of interpretation or application of IEC 60601-1 to all P-Member NCs.</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">This recommendation/interpretation is the result of considerations by a group of nominated experts and has not been formally adopted through any National Committee voting procedure. Distribution is only for information.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The INTRODUCTION of this Technical Report goes on to say:</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“This technical report is intended to convey the results of WG 14&#8217;s work to interested parties such as MANUFACTURERS and test laboratories while retaining the informative nature of the material.</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">This first edition of IEC TR 60601-4-3 contains 93 recommendations, numbered 101 to 193. All these recommendations are based upon IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012.</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The numbering starts with 101 instead of just 1 to ensure that these WG 14 recommendations (101 to 193) will not accidentally be confused with previous issued WG 14 recommendations 1 to 63, which are based on the second edition of IEC 60601-1 and published in IEC TR 62296.”</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The other purpose of this document is that these recommendations may be potential sources for some of the changes to the IEC 60601-1 standard when it is up for it’s next round of changes.  The standards committees, working groups, and maintenance committees for IEC 60601-1 and it’s collateral standards (IEC 60601-1-XX) are in discussion if the next revision will start late this year or early next year.  There is a meeting of all the TC 62 (&amp; SC62A – D) committees in Kobe Japan in Nov 2015 that will discuss this and probably have a formal vote to decide on the fate of the next revision of IEC 60601-1.  I plan to be at these meetings and involved in the discussions and decisions. If this vote is positive the earliest the changes would occur is sometime in 2019.  Stay tuned for more updates on the potential changes to the IEC 60601-1 standards and it’s related collateral standards.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">As there are 93 recommendations sheets I will not note all of them in the below list but a sampling showing a cross section of the ones that draw my attention.  You can see from the list below that many of these were not addressed fully in the standard and this is the start of the resolution to these issues. Many of test houses use this document as their interpretations that they rely on until these decisions are finalized by being adopted into the next revision of the applicable standard (primarily IEC 60601-1).  But realize as the boxed text says these are not formalized so your test lab may not rely on them.  I would suggest that you check first with your Test Lab on the specific issues before assuming they are their interpretations.  You don’t want to use these and find out at the end of your test project that your lab doesn’t agree to the perspective on one or more of these recommendation sheets.  I would hate to see you redesign a product to find out the solution doesn’t meet the requirements for your lab.  As mentioned many labs do accept these but with added text box please be diligent and check first:</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.101             Total PATIENT LEAKAGE CURRENT of a ME SYSTEM</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.102             Pollution degree for MOPP</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.103             Transients on d.c. mains</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.104             Altitude factor for DEFIBRILLATION-PROOF APPLIED PARTS</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.105             Defibrillation energy protection for MOOP / MOPP</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.106             Overvoltage categories III and IV</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.107             Pollution degree related to different micro/macro environments</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.108             Warnings versus ALARM SIGNALS</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.109             Single Y1 capacitor for MOPP</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.111             CREEPAGE DISTANCE and AIR CLEARANCE for dental equipment</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.112             Short circuiting of one constituent part of DOUBLE INSULATION</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.113             Instability in transport position</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.116             Instability excluding transport position</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.119             Test equipment for recurrent tests according to IEC 62353 testing used within IEC 60601-1 type approval testing</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.124             WORKING VOLTAGE measurement</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.125             Defibrillation test</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.127             PERMANENTLY INSTALLED ME EQUIPMENT in the HOME HEALTHCARE ENVIRONMENT</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.129             Push buttons</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.132             Eye-verification of tester before legibility test</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.125             Labeling: spare parts vs. detachable parts vs. ACCESSORIES</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.144             Impedance of a PROTECTIVE EARTH CONDUCTOR within a DETACHABLE POWER SUPPLY CORD</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.149             Expected voltage on SIP/SOPs</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.151             COMPONENT WITH HIGH-INTEGRITY CHARACTERISTICS</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.153             Critical components</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.166             Keep dry and umbrella symbol</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.167             MOBILE and STATIONARY ME EQUIPMENT with wheels</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.175             Biocompatibility for quasi APPLIED PARTS</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.182             Chargers for ME EQUIPMENT used at home</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.186             Rationale for IP2X</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.187             Battery – limited power</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.191             The SIP/SOP pin to earth TOUCH CURRENT</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3.2.193             MAINS VOLTAGE on APPLIED PART</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">This is a great resource to have throughout your design process and through the testing and beyond.  Always have it available so you can leverage the knowledge of these WG14 experts, including myself.  You can purchase this document from IEC, AAMI, and many other sources.  Go to <a href="http://www.eisnersafety.com/links/"><strong>http://www.eisnersafety.com/links/</strong></a> to find a listing of standards Sales Organizations and also Standards Organizations.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">We are in the process of setting up a standards reconnaissance service where we monitor the MEDICAL ELECTRICAL EQUIPMENT and HOME USE MEDICAL ELECTRICAL standards of your choice.  If you are interested in this service please contact Leo Eisner at <a href="mailto:&#76;&#101;&#111;&#64;&#69;is&#110;e&#114;Safe&#116;y.com">Leo&#64;&#69;&#105;&#115;n&#101;r&#83;a&#102;ety&#46;&#99;&#111;m</a> or 503-244-6151.  We would be happy to discuss what we can do for your organization as Leo is on many of the standards committees that these standards are involved with.  Below is a summary of my involvement in these committees.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Leo is a co-chair of the U.S. TAG (technical advisory group) for IEC/SC 62D, a member of the US TAG for TC 62 (Electrical Equipment in Medical Practice), SC 62A (Common Aspects of Electrical Equipment Used in Medical Practice) and SC 62D (Electromedical equipment).  He is the convener of SC62D JWG9 “Lens removal and vitrectomy devices for ophthalmic surgery”.  Leo is a member of the TC 62/SC 62A/WG 14 (Testing to General Safety Standard – The Working Group is chartered to develop recommendations regarding interpretation &amp; application of IEC 60601-1 to testing of medical electrical equipment, and to deal with general testing requirements not assigned to other maintenance teams.)  To support the increase in demand for medical device Home Use and Wearables Leo is a member of the AAMI committee for Home Use Medical Devices and the US TAG for Active Assisted Living Syc (System Committee for all devices in various categories for the elderly which includes the home use medical device industry).</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Presentation on Navigating FDA&#8217;s Home Use Medical Devices Draft Guidance</title>
		<link>https://eisnersafety.com/2013/06/10/presentation-on-navigating-fdas-home-use-medical-devices-draft-guidance/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=presentation-on-navigating-fdas-home-use-medical-devices-draft-guidance</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Mon, 10 Jun 2013 20:19:19 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[510(k)]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[60601-1-11]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[AAMI]]></category>
		<category><![CDATA[AAMI ES 60601-1 2005/A1 2012]]></category>
		<category><![CDATA[AAMI ES 60601-1:05/A1:12]]></category>
		<category><![CDATA[AAMI ES 60601-1:2005 / A1:2012]]></category>
		<category><![CDATA[AAMI ES 60601-1:2005/A1:2012]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[AAMI ES60601-1/C1]]></category>
		<category><![CDATA[AAMI HA60601-1-11]]></category>
		<category><![CDATA[AAMI/IEC TIR 62348:12]]></category>
		<category><![CDATA[Amendment 1]]></category>
		<category><![CDATA[Amendment 1 to IEC 60601-1:2005]]></category>
		<category><![CDATA[ANSI]]></category>
		<category><![CDATA[ANSI.AAMI/IEC]]></category>
		<category><![CDATA[ANSI/AAMI ES 60601-1:2005/A1:2012]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11:2011]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11:2011 (IEC 60601-1-11:2010]]></category>
		<category><![CDATA[ANSI/AAMI/IEC TIR 62348:2012]]></category>
		<category><![CDATA[CDRH]]></category>
		<category><![CDATA[consolidated edition]]></category>
		<category><![CDATA[Environmental Considerations]]></category>
		<category><![CDATA[ES 60601-1:2005 / A1:2012]]></category>
		<category><![CDATA[ESC]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[FDA Guidance]]></category>
		<category><![CDATA[FDA's Home Use Initiative]]></category>
		<category><![CDATA[Home Healthcare Environments]]></category>
		<category><![CDATA[Home Use]]></category>
		<category><![CDATA[Home Use Environment]]></category>
		<category><![CDATA[Home Use Initiative]]></category>
		<category><![CDATA[Home Use Med Dvcs]]></category>
		<category><![CDATA[Human Factors]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[IEC 60601-1 + A1]]></category>
		<category><![CDATA[IEC 60601-1 3rd ed]]></category>
		<category><![CDATA[IEC 60601-1-11 1st ed.]]></category>
		<category><![CDATA[IEC 60601-1-11:2010]]></category>
		<category><![CDATA[IEC TR 62348]]></category>
		<category><![CDATA[IEC TR 62348 2nd ed.]]></category>
		<category><![CDATA[IEC TR 62348 2nd edition]]></category>
		<category><![CDATA[IEC TR 62348:12]]></category>
		<category><![CDATA[IEC TR 62348:2012]]></category>
		<category><![CDATA[IEC TR62348]]></category>
		<category><![CDATA[IEC TR62348 2012]]></category>
		<category><![CDATA[IEC TR62348 2nd ed.]]></category>
		<category><![CDATA[IEC TR62348 2nd edition]]></category>
		<category><![CDATA[IEC TR62348:12]]></category>
		<category><![CDATA[IEC TR62348:2012]]></category>
		<category><![CDATA[IEC60601]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[IEC60601-1-11]]></category>
		<category><![CDATA[international electrotechnical commission]]></category>
		<category><![CDATA[Labeling]]></category>
		<category><![CDATA[Labels]]></category>
		<category><![CDATA[Marking]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[medical electrical equipment]]></category>
		<category><![CDATA[moderate changes]]></category>
		<category><![CDATA[moderate impact]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[significant impact]]></category>
		<category><![CDATA[Usability]]></category>
		<category><![CDATA[Usability Analysis]]></category>
		<category><![CDATA[Use Environments]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3381</guid>

					<description><![CDATA[Leo Eisner will be presenting on the topic “Navigating FDA’s Draft Guidance on Home Use Medical Devices” at an FX Conferences event on 11 July, 2013 (Thurs) at 11:00AM – Noon (Pacific), 2:00PM – 3:00PM (Eastern).  You don’t have to]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Leo Eisner will be presenting on the topic “Navigating FDA’s Draft Guidance on Home Use Medical Devices” at an FX Conferences event on 11 July, 2013 (Thurs) at 11:00AM – Noon (Pacific), 2:00PM – 3:00PM (Eastern).  You don’t have to leave your office to join in on the presentation and as a <strong><em>special thank you for visiting us at Eisner Safety Consultants you can get a $50.00 discount.<br />
</em></strong></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong><span id="more-3381"></span>What’s it about:</strong>  The FDA published its draft guidance on Design Considerations for Devices Intended for Home Use in December of 2012, as part of an initiative started back in April 2010 “to support the safe use of medical devices in the home.” The guidance document is a significant step forward helping manufacturers understand the design criteria, user environments to consider, environmental considerations, and labeling issues. It also looks at other standards and FDA guidance manufacturers should consider, as well as post-market considerations, and other vital aspects of designing and developing devices that are intended to make the devices safer and easier to use.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Join us for this timely and informative audio conference presentation as our speaker takes attendees on a guided tour of the draft guidance. The presentation reviews the key points of the document as it relates to the IEC 60601-1-11 standard (Home Use Medical Electrical Equipment), human factors and usability (user environment), environmental considerations, labeling, and design controls (including risk management).<br />
</span><br />
<span style="font-family: arial, helvetica, sans-serif; font-size: small;"> <strong>This audio conference will cover:</strong></span></p>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Variations in the definition of home-use device under FDA and IEC 60601-1-11</span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">How the draft guidance relates to FDA’s Medical Device Home Use Initiative</span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Environmental considerations discussed in the draft guidance</span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">User environments to be considered</span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Key elements to keep in mind when designing home-use devices</span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Labeling considerations</span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Post-market considerations</span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: small;">And more</span></li>
</ul>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">To <strong><em>find out more about the presentation &amp; discount ($50.00 off regular price) <a href="http://www.eisnersafety.com/events/">click here</a></em></strong> for the details and also some other <strong><em><a href="http://www.eisnersafety.com/Events#Past_Presentations">past presentations</a></em></strong> that Eisner Safety Consultants have presented for FX Conferences previously.</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Med Electronic Dvc Soln&#8217;s Trade Pub&#8217;ed Article by Leo Eisner on FDA Home Use Draft Guidance Doc</title>
		<link>https://eisnersafety.com/2013/03/02/med-electronic-dvc-solns-trade-pubed-article-by-leo-eisner-on-fda-home-use-draft-guidance-doc/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=med-electronic-dvc-solns-trade-pubed-article-by-leo-eisner-on-fda-home-use-draft-guidance-doc</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Sat, 02 Mar 2013 06:48:58 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[510(k)]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[AAMI]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[AAMI HA60601-1-11]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11:2011]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11:2011 (IEC 60601-1-11:2010]]></category>
		<category><![CDATA[CDRH]]></category>
		<category><![CDATA[Collateral Standard]]></category>
		<category><![CDATA[consensus standards]]></category>
		<category><![CDATA[CSA]]></category>
		<category><![CDATA[draft guidance document]]></category>
		<category><![CDATA[EIsner]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[FDA Consensus Standard]]></category>
		<category><![CDATA[FDA Consensus Standards]]></category>
		<category><![CDATA[FDA Draft Guidance]]></category>
		<category><![CDATA[FDA Draft Guidance on Home Use Devices]]></category>
		<category><![CDATA[healthcare environment]]></category>
		<category><![CDATA[healthcare facility]]></category>
		<category><![CDATA[home environment]]></category>
		<category><![CDATA[home healthcare]]></category>
		<category><![CDATA[Home Healthcare Environments]]></category>
		<category><![CDATA[Home Use]]></category>
		<category><![CDATA[Home Use Devices]]></category>
		<category><![CDATA[Home Use Environment]]></category>
		<category><![CDATA[Home Use Med Dvcs]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[iec 60601]]></category>
		<category><![CDATA[IEC 60601-1-11]]></category>
		<category><![CDATA[IEC 60601-1-11 1st ed.]]></category>
		<category><![CDATA[IEC 60601-1-11:2010]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[IEC60601-1-11]]></category>
		<category><![CDATA[Intertek]]></category>
		<category><![CDATA[Long Term Care]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[medical electrical equipment]]></category>
		<category><![CDATA[national deviations]]></category>
		<category><![CDATA[nursing home]]></category>
		<category><![CDATA[nursing home environment]]></category>
		<category><![CDATA[professional healthcare]]></category>
		<category><![CDATA[professional healthcare facility]]></category>
		<category><![CDATA[Recognized Consensus Standard]]></category>
		<category><![CDATA[Recognized Consensus Standard Database]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[TÜV]]></category>
		<category><![CDATA[TUV SUD]]></category>
		<category><![CDATA[UL]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3191</guid>

					<description><![CDATA[The FDA&#8217;s Home Use Draft Guidance Document has drawn a lot of attention since it was published on 12 Dec 2012.  The article that the Medical Electronic Device Solutions (MEDS) Trade Publication released on February 2013 is titled FDA Issues Draft]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The FDA&#8217;s Home Use Draft Guidance Document has drawn a lot of attention since it was published on 12 Dec 2012.  The article that the Medical Electronic Device Solutions (MEDS) Trade Publication released on February 2013 is titled <strong><a href="http://medsmagazine.com/2013/02/fda-issues-draft-guidance-on-medical-devices-intended-for-home-use/" target="_blank" rel="noopener noreferrer">FDA Issues Draft Guidance on Medical Devices Intended for Home Use</a></strong>.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span id="more-3191"></span>In Addition to this article I have blogged on the topic a <strong><a href="http://www.EisnerSafety.com/mddi-articles-on-home-use-fda-draft-guidance-be-aware" target="_blank" rel="noopener noreferrer">couple other times</a></strong> so if you want to see more material (<strong><a href="http://www.eisnersafety.com/fda-issues-draft-guidance-on-meddvcs-intended-for-home-use/" target="_blank" rel="noopener noreferrer">original post</a></strong>) on the topic please continue to read on more of the details and experiences that impact many different people in many different ways (some good and some not so good) on the use of Medical Devices in the Home Use environment and how that impacts the users and their families that use these old and new technologies in the home.  Sometime these devices really are only designed for the hospital setting like some IV pumps, patients may have trouble with them to the point that patients pass away, which is a real tragedy no matter how you look at it.  There are 2 MD&amp;DI articles on the <strong><a href="http://www.mddionline.com/article/fdas-home-use-draft-guidance-good-not-gospel" target="_blank" rel="noopener noreferrer">Home Use Draft Guidance</a></strong> and one of the articles deals with an <strong><a href="http://www.mddionline.com/article/how-bad-iv-pump-got-nancy-starks-home" target="_blank" rel="noopener noreferrer">IV pump that probably shouldn&#8217;t have been in the home use environment</a></strong> with really sad results.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If you company needs support dealing with the IEC 60601-1-11 standard for Home Use Environment or with the FDA Home Use Draft Guidance document, working with the Safety Agencies or the National Regulatory bodies (US, Canada, Europe, and around the world) for a product submission and approval <strong><a href="http://www.eisnersafety.com/about_us/">we can provide you with regulatory, product safety, standards compliance, quality system services and more</a></strong>.  Please feel free to contact us at <strong><a href="mailto:&#76;&#101;&#111;&#64;&#69;i&#115;&#110;&#101;rSa&#102;e&#116;ty&#46;&#99;o&#109;">&#76;&#101;&#111;&#64;&#69;i&#115;&#110;&#101;&#114;&#83;&#97;&#102;&#101;&#116;&#116;y&#46;&#99;o&#109;</a></strong> or 503-244-6151.   </span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MD&#038;DI Articles on Home Use FDA Draft Guidance &#038; Be Aware</title>
		<link>https://eisnersafety.com/2013/01/28/mddi-articles-on-home-use-fda-draft-guidance-be-aware/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=mddi-articles-on-home-use-fda-draft-guidance-be-aware</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Mon, 28 Jan 2013 19:51:48 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[510(k)]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[AAMI]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[AAMI HA60601-1-11]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11:2011]]></category>
		<category><![CDATA[ANSI/AAMI HA60601-1-11:2011 (IEC 60601-1-11:2010]]></category>
		<category><![CDATA[CDRH]]></category>
		<category><![CDATA[Collateral Standard]]></category>
		<category><![CDATA[consensus standards]]></category>
		<category><![CDATA[CSA]]></category>
		<category><![CDATA[draft guidance document]]></category>
		<category><![CDATA[EIsner]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[FDA Consensus Standard]]></category>
		<category><![CDATA[FDA Consensus Standards]]></category>
		<category><![CDATA[FDA Draft Guidance]]></category>
		<category><![CDATA[FDA Draft Guidance on Home Use Devices]]></category>
		<category><![CDATA[healthcare environment]]></category>
		<category><![CDATA[healthcare facility]]></category>
		<category><![CDATA[Heather Thompson]]></category>
		<category><![CDATA[home environment]]></category>
		<category><![CDATA[home healthcare]]></category>
		<category><![CDATA[Home Healthcare Environments]]></category>
		<category><![CDATA[Home Use]]></category>
		<category><![CDATA[Home Use Devices]]></category>
		<category><![CDATA[Home Use Environment]]></category>
		<category><![CDATA[Home Use Med Dvcs]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[iec 60601]]></category>
		<category><![CDATA[IEC 60601-1-11]]></category>
		<category><![CDATA[IEC 60601-1-11 1st ed.]]></category>
		<category><![CDATA[IEC 60601-1-11:2010]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[IEC60601-1-11]]></category>
		<category><![CDATA[Intertek]]></category>
		<category><![CDATA[Long Term Care]]></category>
		<category><![CDATA[MD&DI]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device & Diagnostic Industry]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[medical electrical equipment]]></category>
		<category><![CDATA[MOD)]]></category>
		<category><![CDATA[national deviations]]></category>
		<category><![CDATA[nursing home]]></category>
		<category><![CDATA[nursing home environment]]></category>
		<category><![CDATA[professional healthcare]]></category>
		<category><![CDATA[professional healthcare facility]]></category>
		<category><![CDATA[Recognized Consensus Standard]]></category>
		<category><![CDATA[Recognized Consensus Standard Database]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[TÜV]]></category>
		<category><![CDATA[TUV SUD]]></category>
		<category><![CDATA[UBM]]></category>
		<category><![CDATA[UL]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3064</guid>

					<description><![CDATA[This post deals with the FDA&#8217;s Draft Guidance on Home Use Devices.  But it is a two for one (two articles and a note from Leo Eisner about the draft guidance to be aware of so really a 3 for]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">This post deals with the FDA&#8217;s Draft Guidance on Home Use Devices.  But it is a two for one (two articles and a note from Leo Eisner about the draft guidance to be aware of so really a 3 for 1 deal).  The MD&amp;DI Editor-in-Chief, Heather Thompson, wrote two articles on the FDA Home Use Draft Guidance on 24 Jan 2013 that bring some perspective to the situation and also a really heart breaking story directly related to Home Use.  Also, I provide a warning you should be aware of when using/considering/reviewing this draft guidance.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span id="more-3064"></span></span></p>
<p><span style="text-decoration: underline; font-size: small; font-family: arial, helvetica, sans-serif;"><em><strong>Buyer Beware &#8211; Nursing Home Use Issue:</strong></em></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The FDA draft guidance says that the Home Use environment doesn&#8217;t include the use of a medical device in a &#8220;professional healthcare facility&#8221; (a defined term in the draft guidance) setting as noted in the definition for a &#8220;home use device&#8221;.  So, that means if you have a device that is designed only for use in a nursing home environment (a &#8220;professional healthcare facility&#8221; setting per the FDA&#8217;s interpretation) that the FDA won&#8217;t consider it to fall under the FDA&#8217;s draft guidance document and therefore under IEC 60601-1-11:2010 (1st ed.) which is the standard the FDA draft guidance document mentions exclusively, in terms of medical electrical equipment home use device standard.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">I noted that the AAMI version of IEC 60601-1-11 standard which is titled &#8220;ANSI/AAMI HA60601-1-11:2011 (IEC 60601-1-11:2010, MOD)&#8221; has some US national deviations.  The National Deviation of import is that note 2 of the definition for &#8220;Home Healthcare Environment&#8221; (sub-clause 3.2) has been changed from saying that a nursing home is considered to be the &#8220;Home Healthcare Environment&#8221; to be a &#8220;professional healthcare facility&#8221;.   This spurred me to check the FDA&#8217;s List of Recognized Consensus Standards and the standard the FDA has Recognized for this issue is the IEC 60601-1-11:2010 version of the standard and not the AAMI version.  In the FDA&#8217;s Recognition it states &#8220;While this standard (IEC 60601-1-11:2010) recognizes long term care facilities as home use environment, FDA does not consider long term care facilities to be home use environment.&#8221;  This surprised me, somewhat, as the AAMI standard has the exception specifically stated right in the US National Deviations and the FDA&#8217;s lead for the Home Healthcare Initiative Mary Brady is one of the two co-chairs for the AAMI version of the standard.  Meaning it is clear to me that the FDA was well aware of the national deviation that ended up in the US National standard ANSI/AAMI HA60601-1-11 whereas it is not in the IEC version of the standard and never could be as it is an international standard and therefore national deviations are not allowed. This implies to me that the FDA made a mistake (dare I say such a thing) and should have referenced the AAMI HA60601-1-11:2011 standard instead of the IEC 60601-1-11:2010 standard in the FDA draft guidance and as the US National Recognized Consensus Standard.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So the current bottom line is this (remember it is a draft guidance so it may change):  If you have a device intended only for the nursing home environment and you go to a Safety Agency (i.e. UL, CSA, Intertek, TÜV SÜD, etc.) for a Safety Certification Mark you may be forced into the Home Use standard under IEC 60601-1-11:2010 unless you point out to the Safety Test House that there is a US deviation under the AAMI version (AAMI HA60601-1-11:2011) which says that Nursing Home Equipment is a professional use device which means the standard wouldn&#8217;t apply.  That is only if you are going for the US market only.  If you also want the EU or Canada or another country it is likely you may end up needing to get a Safety Agency Mark to IEC 60601-1-11:2010.  If you do get the Nursing Home Use device Safety Agency certified to IEC 60601-1-11:2010 and you go to the FDA for a pre-market submission (i.e. 510(k)) with this as part of your market clearance test data and you use the FDA draft guidance for home use, as well, you may run into some trouble because now the FDA may say this isn&#8217;t a Home Use Device per the draft guidance and so they may ask a lot of questions or they could ask you to rethink your approach and resubmit when you get things straight.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em><span style="text-decoration: underline;"><strong>MD&amp;DI Articles:</strong></span></em></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The two articles are <strong><a href="http://www.mddionline.com/article/fdas-home-use-draft-guidance-good-not-gospel" target="_blank" rel="noopener noreferrer">&#8220;FDA&#8217;s Home Use Draft Guidance: Good But Not Gospel&#8221;</a></strong> and the really heat breaking story <strong><a href="http://www.mddionline.com/article/how-bad-iv-pump-got-nancy-starks-home" target="_blank" rel="noopener noreferrer">&#8220;How a Bad IV Pump Got into Nancy Stark&#8217;s Home&#8221;</a></strong>.  I hope these articles give you some perspective on the draft guidance document and I know I will be sending in a comment to the FDA in regard to the Home Use Draft Guidance based on the above &#8220;Buyer Beware &#8211; Nursing Home Use Issue&#8221; so hopefully the FDA can clarify this and make it clearer to the user of the Guidance document and that it links better to the applicable standard.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em><span style="text-decoration: underline;"><strong>Related Articles:</strong></span></em></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><a href="http://www.eisnersafety.com/fda-on-quest-to-standardize-mandatory-meddvc-labeling/" target="_blank" rel="noopener noreferrer"> FDA on Quest to Standardize Mandatory MedDvc Labeling</a></strong></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><a href="http://www.eisnersafety.com/fda-issues-draft-guidance-on-meddvcs-intended-for-home-use/" target="_blank" rel="noopener noreferrer"> FDA Issues Draft Guidance on MedDvcs Intended for Home Use</a></strong></span></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
