<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Collateral Standards &#8211; Eisner Safety Consultants</title>
	<atom:link href="https://eisnersafety.com/tag/collateral-standards/feed/" rel="self" type="application/rss+xml" />
	<link>https://eisnersafety.com</link>
	<description>Regulatory &#38; Safety Experts for Global Medical Device Approvals</description>
	<lastBuildDate>Sun, 12 Jun 2022 18:04:18 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://eisnersafety.com/wp-content/uploads/2025/08/favicon-45x45.png</url>
	<title>Collateral Standards &#8211; Eisner Safety Consultants</title>
	<link>https://eisnersafety.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Interpretation Sheet on Essential Performance &#038; Single Fault Condition for IEC 60601-1:2005+A1:2012</title>
		<link>https://eisnersafety.com/2021/03/15/interpretation-sheet-on-essential-performance-single-fault-condition-for-iec-60601-12005a12012/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=interpretation-sheet-on-essential-performance-single-fault-condition-for-iec-60601-12005a12012</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 04:02:28 +0000</pubDate>
				<category><![CDATA[60601 Series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 A2]]></category>
		<category><![CDATA[60601-1-2]]></category>
		<category><![CDATA[60601-1-2, 4th ed.]]></category>
		<category><![CDATA[Essential Performance]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[Mar 2021]]></category>
		<category><![CDATA[Single Fault Condition]]></category>
		<category><![CDATA[Standards Development]]></category>
		<category><![CDATA[60601]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[60601-1 3rd ed. Amendment 1]]></category>
		<category><![CDATA[60601-2-XX (Particular Stds)]]></category>
		<category><![CDATA[Collateral Standards]]></category>
		<category><![CDATA[Essential Performnance]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[Interpretation Sheet]]></category>
		<category><![CDATA[Particular Standards]]></category>
		<guid isPermaLink="false">https://eisnersafety.com/?p=6872</guid>

					<description><![CDATA[Essential Performance (EP) initially came into the IEC 60601 series of standards when the 3rd edition of IEC 60601-1:2005 was published.  The definition was quite confusing and many manufacturers, regulators and test houses had a hard time with it and how to apply it properly.  In 3rd edition (2005) + amendment 1 (2012) some clarification came into play which made it easier to understand but there is still a fair amount of confusion.  ]]></description>
										<content:encoded><![CDATA[
<figure class="wp-block-image size-large"><img fetchpriority="high" decoding="async" width="1000" height="667" src="https://eisnersafety.com/eisnersafetycom/wp-content/uploads/2021/03/Hand-holding-an-insuline-pump.jpg" alt="" class="wp-image-6875" srcset="https://eisnersafety.com/wp-content/uploads/2021/03/Hand-holding-an-insuline-pump.jpg 1000w, https://eisnersafety.com/wp-content/uploads/2021/03/Hand-holding-an-insuline-pump-600x400.jpg 600w, https://eisnersafety.com/wp-content/uploads/2021/03/Hand-holding-an-insuline-pump-300x200.jpg 300w, https://eisnersafety.com/wp-content/uploads/2021/03/Hand-holding-an-insuline-pump-768x512.jpg 768w" sizes="(max-width: 1000px) 100vw, 1000px" /></figure>



<p class="has-medium-font-size">Essential Performance (EP) initially came into the IEC 60601 series of standards when the 3rd edition of IEC 60601-1:2005 was published.  The definition was quite confusing and many manufacturers, regulators and test houses had a hard time with it and how to apply it properly.  In 3rd edition (2005) + amendment 1 (2012) some clarification came into play which made it easier to understand but there is still a fair amount of confusion.  </p>



<p class="has-medium-font-size">About 2 years ago a test lab did some research and brought up the issue that a significant number of test reports (a high percentage of them) of critical devices didn&#8217;t define essential performance appropriately to the Sub Committee SC62A on &#8220;Common aspects of electrical equipment used in medical practice&#8221;.  From this research, an ad-hoc group was formed to come up with a solution.  </p>



<p class="has-medium-font-size">The initial solution was to come up with this Interpretation Sheet (ISH) to explain Essential Performance (clause 4.3 which is not as clear as the ISH but for those that know the standard have been doing it this way for years) and Single Fault Condition (SFC) (clause 4.7) that is related to Essential Performance.   Access a copy thru the IEC website if you know where to find it or the easier route is to download it <strong><a rel="noreferrer noopener" aria-label="here (opens in a new tab)" href="https://eisnersafety.com/eisnersafetycom/wp-content/uploads/2021/03/ISH-1-IEC-60601-1-ed-3.1-EP-SFC.pdf" target="_blank">here</a></strong>.  Note, this document doesn&#8217;t cover all the issues about Essential Performance as it is a complex situation but it does help explain some of the issues involved.  The ISH per IEC requirements is limited to 2 pages of written text of explanation allowed by IEC requirements and so has a constraint on how detailed it can get.  It is good for explaining the concept for the General standard IEC 60601-1, edition 3.1 which covers also ed. 3.2 (no change there).  The General standard concept is based on limits but for some Particular standards (IEC 60601-2-XX or IEC/ISO80601-2-XX), limits don&#8217;t work for all products applicable (not all display-based product that the clinical function is based on the display function for example).  But the ISH doesn&#8217;t really get into the details of how EP deals with Particular standards much (covered a little in the ISH) so that really needs to be looked at further still.</p>



<p class="has-medium-font-size">So, what is the next step?  This ad-hoc group with the help of some additional people in the standards development community (I hope to be in this group) will start in the next couple of months (probably after the IEC TC 62 General meeting of April 12 &#8211; 23, 2021) to work on a guidance document to provide further guidance on EP as I still find that many regulators around the world, test labs, and manufacturers all have varying understanding of what EP &amp; SFC are.  </p>



<p class="has-medium-font-size">This varying understanding has a huge impact on projects as if say the test lab asks the manufacturer what their EP is, the manufacturer may say I don&#8217;t have any, the test lab will check the test report form (TRF) as none.  When gets to say FDA the first thing FDA would ask is why is there no EP on the device?  If found out there is EP the client would have to retest under the applicable IEC 60601-1, Particular (60601-2-XX/80601-2-XX) and Collateral Standards (60601-1-XX) + the EM Disturbances standard IEC 60601-1-2 which would add cost and time delays to a project. </p>



<p class="has-medium-font-size">Need help with Essential Performance.  Feel free to schedule a call with Leo www.EisnerSafety.com/Schedule-Call/ or contact Leo at&nbsp;L&#101;&#111;&#64;&#69;&#105;&#115;n&#101;r&#83;&#97;f&#101;&#116;&#121;.&#99;&#111;m.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DRAFT results implementation of 3Ed (EN60601 series) for CE marking</title>
		<link>https://eisnersafety.com/2011/10/06/draft-results-implementation-of-3ed-en60601-series-for-ce-marking/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=draft-results-implementation-of-3ed-en60601-series-for-ce-marking</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Thu, 06 Oct 2011 20:29:01 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[60601]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[60601-1 3rd ed. Amendment 1]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[Amendment 1]]></category>
		<category><![CDATA[CENELEC]]></category>
		<category><![CDATA[CLC/TC 62]]></category>
		<category><![CDATA[COCIR]]></category>
		<category><![CDATA[Collateral]]></category>
		<category><![CDATA[Collateral Standard]]></category>
		<category><![CDATA[Collateral Standards]]></category>
		<category><![CDATA[draft document]]></category>
		<category><![CDATA[electrical equipment]]></category>
		<category><![CDATA[en 60601]]></category>
		<category><![CDATA[EN 60601-1]]></category>
		<category><![CDATA[EN 60601-1 3rd ed]]></category>
		<category><![CDATA[EN 60601-1 3rd edition]]></category>
		<category><![CDATA[EN IEC 60601-1 3rd edition]]></category>
		<category><![CDATA[EN IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[EN60601]]></category>
		<category><![CDATA[EN60601-1]]></category>
		<category><![CDATA[EU Notified Body]]></category>
		<category><![CDATA[european medical device]]></category>
		<category><![CDATA[Guidance Document]]></category>
		<category><![CDATA[Hazard Analysis]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[IEC 60601-1 3rd ed]]></category>
		<category><![CDATA[IEC 60601-1 3rd edition]]></category>
		<category><![CDATA[IEC TC62]]></category>
		<category><![CDATA[IEC60601]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed. Amendment 1]]></category>
		<category><![CDATA[ISO 14971]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[medical device directives]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[NB-MED]]></category>
		<category><![CDATA[NBMED]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Particular]]></category>
		<category><![CDATA[Particular Standard]]></category>
		<category><![CDATA[Particular Standards]]></category>
		<category><![CDATA[Power Supplies]]></category>
		<category><![CDATA[Risk Analysis]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[Risk Management File]]></category>
		<category><![CDATA[RMF]]></category>
		<category><![CDATA[TC 62]]></category>
		<category><![CDATA[TC62]]></category>
		<category><![CDATA[TEAM-NB]]></category>
		<category><![CDATA[Transition]]></category>
		<category><![CDATA[Transition Period]]></category>
		<category><![CDATA[Transition Process]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=2229</guid>

					<description><![CDATA[This article is an update to the June 24, 2011 article &#8220;EU EN IEC 60601-1 3rd ed. Request for Issues on the use of the Std for CE-Conformity&#8221; On October 1, 2011 the DRAFT &#8220;FAQ related to Implementation of EN]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">This article is an update to the June 24, 2011 <a href="http://www.eisnersafety.com/eu-en-iec60601-1-3rd-ed-request-for-issues-on-the-use-of-the-std-for-ce-conformity/" target="_blank" rel="noopener noreferrer">article &#8220;EU EN IEC 60601-1 3rd ed. Request for Issues on the use of the Std for CE-Conformity&#8221;</a></span></span></p>
<p><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">On October 1, 2011 the DRAFT &#8220;FAQ related to Implementation of EN 60601-1:2006 Clarification of open issues&#8221; was issued and this <a title="EN60601-1 Implementation ISSUES final draft for NB-MED V1.0" href="http://www.eisnersafety.com/wp-content/uploads/2011/10/EN_60601-1_Implementation_ISSUES_final_draft_for_NB-MED_V1-0.pdf">DRAFT document</a> is being sent to <a href="http://www.team-nb.org/" target="_blank" rel="noopener noreferrer">NB-MED</a> for commenting on the document.  <a href="http://www.team-nb.org/" target="_blank" rel="noopener noreferrer">NB-MED</a> is also known as <a href="http://www.team-nb.org/" target="_blank" rel="noopener noreferrer">TEAM NB</a>.  This organization is the European Association of Notified Bodies for Medical Devices which covers the MDD (93/42/EEC), AIMDD (90/385/EEC), and IVDD (98/79/EC).  This group publishes guidances that are agreed on by the Medical Device Directives (93/42/EEC, 90/385/EEC, and 98/79/EC) Notified Bodies. Once all the responses are agreed to it is anticipated that the document will be released as an NB-MED guidance document.</span></span></span></p>
<p><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">The History of this <a title="EN60601-1 Implementation ISSUES final draft for NB-MED V1.0" href="http://www.eisnersafety.com/wp-content/uploads/2011/10/EN_60601-1_Implementation_ISSUES_final_draft_for_NB-MED_V1-0.pdf">DRAFT document</a> is restated below.  Note that any &#8220;click here&#8221; links are not live in the below text but are live in the actual <a title="EN60601-1 Implementation ISSUES final draft for NB-MED V1.0" href="http://www.eisnersafety.com/wp-content/uploads/2011/10/EN_60601-1_Implementation_ISSUES_final_draft_for_NB-MED_V1-0.pdf">DRAFT document</a>.</span></span></span></span></p>
<p style="padding-left: 30px;"><strong><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">History </span></span></span></span></strong></p>
<p style="padding-left: 30px;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">During spring 2011, it was realized that the use of EN 60601-1 and its many family members in demonstrating compliance with the relevant and applicable requirements of the European medical device regulatory framework was not too trivial. While relevant guidance on the matter had been published at the CENELEC website as a Q&amp;A document (click here), some Notified Bodies were giving advice that was felt to be not in line with that guidance. On other occasions, questions were raised that were not covered in the guidance.</span></span></span></span></p>
<p style="padding-left: 30px;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">So, it was concluded that the situation for electrical equipment in medical practice was not totally clear and that additional guidance would be useful. Further contact with the chair of the NB-MED confirmed this desirability, and a small group of experts was established. This group developed an enquiry asking for &#8220;practical issues in the implementation&#8221;, that was sent to many stakeholders in June 2011(see Annex 1). Also at the international level of IEC the request was distributed (62A/769/INF).</span></span></span></span></p>
<p style="padding-left: 30px;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">The response to the request was beyond expectation and the small team of experts, initially consisting of three, was expanded with Dr. Klaus Neuder of DKE (Frankfurt, Germany).</span></span></span></span></p>
<p style="padding-left: 30px;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">End of July 2011, the work on digesting the issues submitted until then started and it took until end of September 2011 until all material had been thoroughly discussed and answers formulated to the questions that were raised. In some cases, the questions were slightly amended to make them a little more general, and a few additional &#8220;connecting&#8221; questions were developed by the team.</span></span></span></span></p>
<p style="padding-left: 30px;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">It is believed that the answers, developed in close team cooperation, present a fair response to the issues brought forward and that they can be used as a reference for all stakeholders.</span></span></span></span></p>
<p style="padding-left: 30px;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Now it is time for the NB-MED to scrutinize the proposed responses and see if they are also acceptable to all members of NB-MED. The NB-MED comments are kindly awaited by the end of October 2011, at the same e-mail address that was used for the initial submission of the issues: <a href="mailto:60&#54;&#48;&#49;E&#100;3&#46;NBM&#69;&#68;&#46;i&#115;&#115;&#117;&#101;s&#64;&#103;&#109;&#97;il&#46;c&#111;&#109;" target="_blank" rel="noopener noreferrer">6&#48;&#54;&#48;1&#69;d&#51;&#46;&#78;&#66;&#77;ED&#46;&#105;&#115;&#115;u&#101;s&#64;&#103;m&#97;i&#108;&#46;c&#111;m</a>, using the form supplied together with this document.</span></span></span></span></p>
<p style="padding-left: 30px;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Happy reading!</span></span></span></span></p>
<p style="padding-left: 30px;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">The 60601-1 Issues Team:</span></span></span></span></p>
<p style="padding-left: 30px;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Dr. Wolfgang Leetz, Dr. Peter Linders Dr. Klaus Neuder Mr. Martin Schneeberg</span></span></span></span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>EU EN IEC60601-1 3rd ed. Request for Issues on the use of the Std for CE-Conformity</title>
		<link>https://eisnersafety.com/2011/06/24/eu-en-iec60601-1-3rd-ed-request-for-issues-on-the-use-of-the-std-for-ce-conformity/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=eu-en-iec60601-1-3rd-ed-request-for-issues-on-the-use-of-the-std-for-ce-conformity</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Fri, 24 Jun 2011 06:58:11 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[CENELEC]]></category>
		<category><![CDATA[CLC/TC 62]]></category>
		<category><![CDATA[COCIR]]></category>
		<category><![CDATA[Collateral Standards]]></category>
		<category><![CDATA[EN IEC 60601-1 3rd edition]]></category>
		<category><![CDATA[EN IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[IEC TC62]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[NBMED]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Particular Standards]]></category>
		<category><![CDATA[Transition Period]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=2158</guid>

					<description><![CDATA[Do you have EU transition period questions related to the MDD &#38; AIMDD Harmonized Standard EN IEC 60601-1:2006 (or sometimes known as 3rd edition of EN IEC 60601-1), its&#8217; collaterals (EN IEC60601-1-XX) and its&#8217; particulars (EN IEC 60601-2-XX) standards?  If]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Do you have EU transition period questions related to the MDD &amp; AIMDD Harmonized Standard EN IEC 60601-1:2006 (or sometimes known as 3rd edition of EN IEC 60601-1), its&#8217; collaterals (EN IEC60601-1-XX) and its&#8217; particulars (EN IEC 60601-2-XX) standards?  If you do, you have until June 30th, 2011 to submit your questions to an expert team, at </span></span><a href="mailto:&#54;&#48;6&#48;1Ed3&#46;N&#66;&#77;&#69;&#68;.is&#115;u&#101;&#115;&#64;gm&#97;&#105;&#108;&#46;co&#109;"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">&#54;0&#54;&#48;&#49;&#69;&#100;3&#46;NBM&#69;&#68;.iss&#117;&#101;&#115;&#64;gm&#97;il.&#99;o&#109;</span></span></a><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">, that will endeavor to answer these questions by September 30, 2011 for this 1st round of this new group.  Please read the below letter that have been sent to many different places around the world but note the only questions that will be answered are not the technical issues of how to apply 3rd ed. of EN IEC 60601-1 or even any transitional questions in regard to the FDA (ANSI/AAMI/ES 60601-1), Health Canada (CAN/CSA C22.2 No. 60601:08), MHLW (Japan), or SFDA (China) but only with respect to the implementation of EN IEC 60601-1, 3rd edition in regard to CE Marking under the MDD and AIMDD.  Several years ago there was a </span></span><a title="Q&amp;A ON THE EN 60601 SERIES OF STANDARDS IN RELATION TO THE MDD &amp; AIMD" href="ftp://ftp.cencenelec.eu/CENELEC/TCs/CollateralStandardsMDD.pdf" target="_blank" rel="noopener noreferrer"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">FAQ document</span></span></a><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"> issued that was on the older version of the CENELEC website when the site changed that link disappeared.  Only just before this letter (below) was issued about the submission of additional transitional questions with regard to 3rd edition of EN IEC 60601-1 did this </span></span><a title="Q&amp;A ON THE EN 60601 SERIES OF STANDARDS IN RELATION TO THE MDD &amp; AIMD" href="ftp://ftp.cencenelec.eu/CENELEC/TCs/CollateralStandardsMDD.pdf" target="_blank" rel="noopener noreferrer"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">FAQ document</span></span></a><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"> show up again on the CENELEC website in the </span></span><a title="CENELEC Medical Equipment Technology Sector" href="http://www.cenelec.eu/aboutcenelec/whatwedo/technologysectors/medicalequipment.html" target="_blank" rel="noopener noreferrer"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">Medical Equipment Technology Sector</span></span></a><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">.  This </span></span><a title="Q&amp;A ON THE EN 60601 SERIES OF STANDARDS IN RELATION TO THE MDD &amp; AIMD" href="ftp://ftp.cencenelec.eu/CENELEC/TCs/CollateralStandardsMDD.pdf" target="_blank" rel="noopener noreferrer"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">FAQ document</span></span></a><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"> is an excellent primer for understanding some of the transitional issues for 3rd ed of EN IEC 60601-1 with respect to the MDD &amp; AIMDD.  With this group hopefully collecting additional transition issues the </span></span><a title="Q&amp;A ON THE EN 60601 SERIES OF STANDARDS IN RELATION TO THE MDD &amp; AIMD" href="ftp://ftp.cencenelec.eu/CENELEC/TCs/CollateralStandardsMDD.pdf" target="_blank" rel="noopener noreferrer"><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">FAQ document</span></span></a><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"> will grow and improve our overall understanding of some of the challenges with the transition of EN IEC 60601-1 3rd edition and its&#8217; 60 or so related standards.</span></span></p>
<p><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">I would like to also thank Martin Schneeberg &amp; Peter Linders for allowing me to share this with all my clients and website visitors. </span></span></p>
<p><br class="spacer_" /></p>
<p align="center"><strong><span style="color: #0000ff;">Implementation of EN IEC 60601-1 3rd edition </span></strong><strong><span style="color: #0000ff;"> </span></strong></p>
<p align="center"><strong><span style="color: #0000ff;">Request for Issues </span></strong></p>
<p align="center"><strong><span style="color: #0000ff;">on the use of the standard for CE-conformity purposes</span></strong></p>
<p>When the transition period was defined for EN IEC 60601-1:2006 (replacing the 1988 version with its two amendments), several questions arose. These questions were included in a FAQ document that was posted at the CENELEC web site (click <a href="http://www.cenelec.eu/aboutcenelec/whatwedo/technologysectors/medicalequipment.html">here</a>) to give all users the same interpretation<a href="#_ftn1">[1]</a>: (click <a href="file://localhost/ftp/::ftp.cencenelec.eu:CENELEC:TCs:CollateralStandardsMDD.pdf">here</a>).</p>
<p>The transition period, after which only the 2006 edition will be giving presumption of conformity with the relevant Essential Requirements of the Medical Device Directive (93/42/EC), is now well underway. As an increasing number of manufacturers are implementing this version of the standard, more questions come up. In particular this is the case in conversations between manufacturers and involved authorities or Notified Bodies considering CE-conformity purposes.</p>
<p>In an attempt to support these discussions, and to harmonize responses, we are looking for specific matters that have arisen and that may have wider relevance. Together with regulatory experts, we will seek answers to those matters that reflect a consensus opinion of the Medical Notified Bodies. Clearly, this is <strong><span style="text-decoration: underline;">not</span></strong> a request for technical matters, e.g., for required test conditions, but rather unclear situation. A few examples of such matters are given in the annex.</p>
<p>If you know of such matters, or even have experienced some yourselves, please share these. If you have reached agreement on these matters or you have proposals for the same, and wish to share: these are also very welcome. As indicated, the matters will be compiled and given to experts for sound advice, followed by scrutiny from NB-MED experts, resulting in the best available recommendations for the matters indicated. This advice will be made publicly available.</p>
<p>Please submit your contributions to: <a href="mailto:&#54;0&#54;&#48;&#49;&#69;&#100;&#51;.&#78;&#66;MED&#46;i&#115;su&#101;&#115;&#64;&#103;&#109;&#97;&#105;l.&#99;&#111;&#109;">6&#48;601Ed3.N&#66;M&#69;D&#46;i&#115;&#115;u&#101;s&#64;&#103;ma&#105;l&#46;c&#111;m</a>. Note that not all contributions may receive individual responses. We will start work with material submitted by 30 June 2011, yet contributions after that date remain welcome. We expect first results by 30 September.</p>
<p>Thank you for your consideration and valuable contributions.</p>
<p><strong>Martin Schneeberg </strong>(TÜV SÜD PRODUCT SERVICE, member of UK 811.1, IEC TC62A, WG14, MT28, A1PMT, IECEE RM TF)</p>
<p><strong>Wolfgang Leetz </strong>(Siemens AG, Healthcare Sector, chair of DKE Division 8 (electro medical equipment, electro acoustic, ultrasound, laser), chair of COCIR Standardization Policy Focus Group) <strong> </strong></p>
<p><strong>Peter Linders </strong>(Philips Healthcare, chair of CENELEC TC 62, chair of COCIR Technical and Regulatory Affairs Committee, member of IEC/TC 62 CAG, A1PMT)</p>
<p><strong>Annex – Examples of questions sought</strong></p>
<p><strong>Q1. Valid EC Design-Examination certificate period vs. DOCOPOCOSS: 2012-06-01:</strong><br />
 Example: Suppose an MDD class IIB or III electrical medical equipment was placed on the EEA in 2009. It has a signed EC Design-Examination Certificate by a NB based on 2Ed EN 60601-1, valid until 2014-01-01 (five years).</p>
<p>Question: Is this product affected by the DOCOPOCOSS related to EN 60601-1:1990 (+ am1 + am2), June 1st 2012? Keep in mind that a valid EC certificate has been issued by a NB which is valid 5 years up to 2014.</p>
<p><strong>Q2. Future totally new particular standards:</strong><br />
 For a specific MEE does not exist a specific particular standard related to 2Ed EN 60601-1. However, for this specific MEE a totally new particular standard related to the 3Ed EN 60601-1:2006 is work in progress. This question is relevant at least for: <br />
 &#8211; 60601-2-63: for dental extra-oral x-ray equipment,<br />
 &#8211; 60601-2-64: light ion accelerators,<br />
 &#8211; 60601-2-65: for dental intra-oral x-ray equipment,<br />
 &#8211; 60601-2-66: hearing aids and hearing systems</p>
<p>Officially such MEE’s shall fulfil the complete 3Ed EN 60601-1:2006 plus the relevant particular standard 60601-2-XY at the date 2012-06-01, unless there is a specific transition period for the applicable particular standard. Usually no specific transition period for the totally new particular standards are defined in the OJ, therefore, 2012-06-01 will apply.</p>
<p>Is there any guidance beyond the general advice to discuss specific problems related to the application of these new standards with the NB and using Risk Management?</p>
<p>Can 3 years transition period for the EN 60601-2-XY be claimed starting from publishing the EN version of the particular standard?</p>
<p><strong>Q3. Is ZLG paper 3.5 A1 legally binding for EU NB’s and MEE manufacturers:<br />
 </strong>The ZLG-paper 3.5 A1 addresses a valid concern extremely clear: <em>&#8220;The missing new assessment by the manufacturer after the end of the &#8220;doc&#8221; or the missing knowledge about the existing of new harmonized standards or scientific knowhow are substantial NON-conformities. If these NON-conformities will not be adequate corrected, the certificates have to be suspended or withdrawn.”</em><br />
 Is this paper legally binding? Am I allowed to ignore it? In clear words: If the “doc” is over and I have not objective evidence about the new 3Ed EN 60601-1:2006 requirements in a point-by-point protocol format, is my NB forced to suspend or withdraw my CE-certificate?</p>
<hr size="1" />
<p><a href="#_ftnref">[1]</a> <strong>Collateral standards under the MDD &amp; AIMD</strong>: CLC/TC 62 questions and answers on the EN 60601-series of standards in relation to the MDD and AIMD</p>
<p><br class="spacer_" /></p>