<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EN ISO 14971:2012 &#8211; Eisner Safety Consultants</title>
	<atom:link href="https://eisnersafety.com/tag/en-iso-149712012/feed/" rel="self" type="application/rss+xml" />
	<link>https://eisnersafety.com</link>
	<description>Regulatory &#38; Safety Experts for Global Medical Device Approvals</description>
	<lastBuildDate>Wed, 02 Jul 2014 08:13:46 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://eisnersafety.com/wp-content/uploads/2025/08/favicon-45x45.png</url>
	<title>EN ISO 14971:2012 &#8211; Eisner Safety Consultants</title>
	<link>https://eisnersafety.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>NBRG Risk Mgmt Draft Consensus Paper on Interpretation &#038; Application of Annexes Z in EN ISO 14971:2012</title>
		<link>https://eisnersafety.com/2014/07/02/nbrg-risk-mgmt-draft-consensus-paper-on-interpretation-application-of-annexes-z-in-en-iso-149712012/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=nbrg-risk-mgmt-draft-consensus-paper-on-interpretation-application-of-annexes-z-in-en-iso-149712012</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Wed, 02 Jul 2014 08:13:46 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[EN ISO 14971]]></category>
		<category><![CDATA[EN ISO 14971:2012]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[ISO 14971]]></category>
		<category><![CDATA[ISO 14971:2007]]></category>
		<category><![CDATA[IVD]]></category>
		<category><![CDATA[IVD Directive]]></category>
		<category><![CDATA[IVDD]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[NBRG]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Notified Body Recommendation Group]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[TEAM-NB]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3979</guid>

					<description><![CDATA[Just released as of June 25, 2014 this NBRG Consensus Paper for the Interpretation and Application of Annexes Z in EN ISO 14971:2012 is finally available.  Be forewarned that the document is not yet adopted by the NBRG, which can only be]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small;"><span style="font-family: arial, helvetica, sans-serif;"><br />
<a href="http://www.eisnersafety.com/wp-content/uploads/2014/07/shareasimageNBRG-RM-Consensus-Paper-Draft.jpg"><img decoding="async" class="alignleft size-full wp-image-3981" style="margin-top: -2px; margin-bottom: -2px;" title="shareasimageNBRG RM Consensus Paper Draft" src="http://www.eisnersafety.com/wp-content/uploads/2014/07/shareasimageNBRG-RM-Consensus-Paper-Draft.jpg" alt="" width="155" height="218" /></a><span style="font-family: arial, helvetica, sans-serif;">Just released as of June 25, 2014 this <strong><a href="http://www.team-nb.org/documents/2014/NBRG_Final_WG%20RM%20Draft_Not_Yet_adopted_142506_2.pdf" target="_blank" rel="noopener noreferrer">NBRG Consensus Paper for the Interpretation and Application of Annexes Z in EN ISO 14971:2012</a> </strong></span></span><span style="font-family: arial, helvetica, sans-serif;">is finally available.  Be forewarned that the document<em style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong> is not yet adopted by the NBRG</strong></em>, which can only be done at the next Meeting in October 2014.  Hopefully it will be adopted at that meeting.  I will check in with my NBRG Risk Management Working Group contacts to find out if they know more about that issue.<span id="more-3979"></span></span></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">But let&#8217;s take this chance to review a little about the document and the history of the EN ISO 14971:2012 Annex Z&#8217;s.  Future posts will get into more details. The following 3 paragraphs come straight from the introduction of the document as the Working Group summarizes the situation really well.  I happen to know a couple of these working group members personally and I know they have a very good handle on the situation and they have provided some very good background.  </span></p>
<p style="padding-left: 30px;"><span style="font-family: arial, helvetica, sans-serif; font-size: small; line-height: 18px;">In October 2010, the regular review of ISO 14971:2007 which is the basis of EN ISO 14971:2009 was closed by a broad majority of votes confirming the existing status and the wide-spread acceptance of this standard in the medical devices community, including competent authorities. In November 2010, the European Commission raised a formal objection against the use of several harmonized standards, including EN ISO 14971, followed by an in-depth assessment of the coverage of the Essential Requirements of the Medical Device Directives (90/385/EEC, 93/42/EEC and 98/79/EC) by these standards.</span></p>
<p style="padding-left: 30px;"><span style="font-family: arial, helvetica, sans-serif; font-size: small;">As a result of these objections, the Annexes Z to EN ISO 14971 were modified, resulting in EN ISO 14971:2012. This amendment of the EN ISO 14971 standard did not modify the normative parts of ISO 14971:20071. The Annexes Z describe the extent of presumption of conformity that can be based on application of the normative requirements of ISO 14971 alone. The “content deviations”, expressed in the revised Annexes Z, between ISO 14971:2007 and the Medical Device Directives have been commented by many experts in the field of risk management and resulted in diverging interpretations from different stakeholders (e.g. manufacturers, notified bodies, competent authorities).</span></p>
<p style="padding-left: 30px;"><span style="font-family: arial, helvetica, sans-serif; font-size: small;">This document has been prepared as a Notified Body Consensus Paper by a working group headed by the NBRG Vice Chair, with representatives from several European Notified Bodies and industry associations COCIR, Eucomed, EDMA and ZVEI. The paper aims to provide a practical interpretation of these “content deviations” to the Medical Device Directives and give guidance as to how to implement the risk management requirements. The work consolidates prior publications of various sources and is intended to facilitate common understanding between industry and Notified Bodies.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">If you would like further info on the consensus document and some history please check out the previous posts below (Latest to Oldest):</span></p>
<ul>
<li><strong style="font-family: arial, helvetica, sans-serif; font-size: small;"><a href="http://www.EisnerSafety.com/mddi-article-collaboration-holds-the-key-to-clarity-on-en-iso-149712012/">MD&amp;DI Article &#8220;Collaboration Holds the Key to Clarity on EN ISO 14971:2012&#8221;</a></strong></li>
</ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><a href="http://www.EisnerSafety.com/nbrg-consensus-document-on-en-iso-149712012-is-on-its-way-mdm-west-14-presentation/">NBRG Consensus Document on EN ISO 14971:2012 Is On Its Way MD&amp;M West &#8217;14 Presentation</a></strong></span><span style="font-size: 13px;"> </span></li>
</ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><a href="http://www.EisnerSafety.com/nbrg-call-for-industry-participation-survey-understanding-annex-z-en-iso-149712012/">NBRG Call for Industry Participation &#8211; Survey Understanding Annex Z EN ISO 14971:2012</a></strong></span></li>
</ul>
<div><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If you need help with Risk Management with respect to the IEC 60601 series of Standards, email Leo Eisner directly at <strong><a href="mailto:Le&#111;&#64;&#69;&#105;sn&#101;&#114;S&#97;&#102;e&#116;&#121;&#46;co&#109;">&#76;&#101;o&#64;&#69;i&#115;&#110;&#101;&#114;&#83;&#97;fety&#46;&#99;om</a></strong>, or call Leo at +1-(503)-244-6151. He is the Principal Consultant of Eisner Safety Consultants (<strong><a title="Link to Eisner Safety Consultants Website" href="http://bit.ly/EisnerSafetyConsultants">bit.ly/EisnerSafetyConsultants</a></strong>).</span></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Status Update on NBRG Risk Management Consensus Document</title>
		<link>https://eisnersafety.com/2014/04/30/status-update-on-nbrg-risk-management-consensus-document-status/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=status-update-on-nbrg-risk-management-consensus-document-status</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Wed, 30 Apr 2014 19:08:52 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[EN ISO 14971]]></category>
		<category><![CDATA[EN ISO 14971:2012]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[ISO 14971]]></category>
		<category><![CDATA[ISO 14971:2007]]></category>
		<category><![CDATA[IVD]]></category>
		<category><![CDATA[IVD Directive]]></category>
		<category><![CDATA[IVDD]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[NBRG]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Notified Body Recommendation Group]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[TEAM-NB]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3814</guid>

					<description><![CDATA[This post is a status update on the NBRG RMWG Risk Management Consensus Document 30 April 2014 &#8211; The NBRG (Notified Body Recommendation Group) Risk Management Working Group (RMWG) membership will have a face to face meeting in mid May to]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><a href="http://www.eisnersafety.com/wp-content/uploads/2014/04/shareasimageENISO14971_2012.png"><img fetchpriority="high" decoding="async" class="alignleft size-medium wp-image-3822" style="margin-top: -2px; margin-bottom: -2px;" title="shareasimageENISO14971_2012" src="http://www.eisnersafety.com/wp-content/uploads/2014/04/shareasimageENISO14971_2012-211x300.png" alt="" width="211" height="300" /></a>This post is a status update on the NBRG RMWG Risk Management Consensus Document</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">30 April 2014 &#8211; The NBRG (Notified Body Recommendation Group) Risk Management Working Group (RMWG) membership will have a face to face meeting in mid May to refine the draft Consensus document on EN ISO 14971:2012.  This meeting has come about because the NBRG RMWG received some feedback recently from the EU Commission and they will consider it and roll it into this document. </span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span id="more-3814"></span>The consensus document&#8217;s purpose is to reduce the confusion around the EU Harmonized Standard <strong><a href="http://webshop.ds.dk/catalog/documents/M265310_attachPV.pdf" target="_blank" rel="noopener noreferrer">EN ISO 14971:2012 Annexes ZA, ZB, &amp; ZC</a></strong> that amends the EN ISO 14971:2009 version of the standard to align with the 3 Medical Devices Directives (the Medical Device, Active Implantable Medical Device, and In Vitro Diagnostic Medical Devices Directives). The previous plan was to have this Consensus document completed and released by Mid to Late April &#8217;14 but at this point it is hoped the NBRG RMWG will have a final released document by the end of June 2014. We look forward to sending good news about the progress of this document over the next month or so.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If you would like further info on the consensus document and some history please check out the previous posts below (Latest to Oldest):</span></p>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><a href="http://www.EisnerSafety.com/mddi-article-collaboration-holds-the-key-to-clarity-on-en-iso-149712012/">MD&amp;DI Article &#8220;Collaboration Holds the Key to Clarity on EN ISO 14971:2012&#8221;</a></strong></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><a href="http://www.EisnerSafety.com/nbrg-consensus-document-on-en-iso-149712012-is-on-its-way-mdm-west-14-presentation/">NBRG Consensus Document on EN ISO 14971:2012 Is On Its Way MD&amp;M West &#8217;14 Presentation</a></strong></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><a href="http://www.EisnerSafety.com/nbrg-call-for-industry-participation-survey-understanding-annex-z-en-iso-149712012/">NBRG Call for Industry Participation &#8211; Survey Understanding Annex Z EN ISO 14971:2012</a></strong></span></li>
</ul>
<div><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If you need help with Risk Management with respect to the IEC 60601 series of Standards, email Leo Eisner directly at <strong><a href="mailto:&#76;&#101;o&#64;Eis&#110;er&#83;afe&#116;y&#46;&#99;&#111;m">&#76;&#101;o&#64;&#69;&#105;&#115;ne&#114;S&#97;fet&#121;&#46;c&#111;m</a></strong>, or call Leo at +1-(503)-244-6151. He is the Principal Consultant of Eisner Safety Consultants (<strong><a title="Link to Eisner Safety Consultants Website" href="http://bit.ly/EisnerSafetyConsultants">bit.ly/EisnerSafetyConsultants</a></strong>).</span></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MD&#038;DI Article &#8220;Collaboration Holds the Key to Clarity on EN ISO 14971:2012&#8221;</title>
		<link>https://eisnersafety.com/2014/03/08/mddi-article-collaboration-holds-the-key-to-clarity-on-en-iso-149712012/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=mddi-article-collaboration-holds-the-key-to-clarity-on-en-iso-149712012</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Sat, 08 Mar 2014 00:11:18 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[EN ISO 14971]]></category>
		<category><![CDATA[EN ISO 14971:2012]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[ISO 14971]]></category>
		<category><![CDATA[ISO 14971:2007]]></category>
		<category><![CDATA[IVD]]></category>
		<category><![CDATA[IVD Directive]]></category>
		<category><![CDATA[IVDD]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[NBRG]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Notified Body Recommendation Group]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[TEAM-NB]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3678</guid>

					<description><![CDATA[7 March 2014 &#8211; MD&#38;DI article written by Leo Eisner of Eisner Safety Consultants about the confusion of the EU Harmonized Standard EN ISO 14971:2012 Annexes ZA, ZB, &#38; ZC that amends the EN ISO 14971:2009 version of the standard]]></description>
										<content:encoded><![CDATA[<p>7 March 2014 &#8211; <strong><a href="http://www.mddionline.com/" target="_blank" rel="noopener noreferrer">MD&amp;DI</a> <a href="http://bit.ly/EN_ISO14971-2012_Consensus_Doc_in_process_with_NBRG" target="_blank" rel="noopener noreferrer">article written by Leo Eisner</a></strong> of Eisner Safety Consultants about the confusion of the EU Harmonized Standard <strong><a href="http://webshop.ds.dk/catalog/documents/M265310_attachPV.pdf" target="_blank" rel="noopener noreferrer">EN ISO 14971:2012 Annexes ZA, ZB, &amp; ZC</a></strong> that amends the EN ISO 14971:2009 version of the standard to align with the 3 Medical Devices Directives (the Medical Device, Active Implantable Medical Device, and In Vitro Diagnostic Medical Devices Directives) and what is being done to reduce the confusion.</p>
<p><span id="more-3678"></span>The NBRG (Notified Body Recommendation Group) Risk Management Working Group is working to put together a consensus document.  A call to industry has been sent out to ask for participation in a survey on how your risk management system aligns with EN ISO 14971:2012 that will help in the direction of this consensus document so please take part in it.  <strong><a href="http://bit.ly/EN_ISO14971-2012_Consensus_Doc_in_process_with_NBRG" target="_blank" rel="noopener noreferrer">Read the article for more details</a></strong> and a post that <strong><a href="http://bit.ly/NBRGSurveyOnAnnexZ_EN_ISO14971_2012" target="_blank" rel="noopener noreferrer">links to the survey</a></strong>.</p>
<p>Past posts on this subject include:</p>
<ul>
<li><strong><a href="http://bit.ly/NBRGConsensusDocENISO14971-12Slides" target="_blank" rel="noopener noreferrer">NBRG Consensus Document on EN ISO 14971:2012 Is On Its Way MD&amp;M West &#8217;14 Presentation</a></strong></li>
<li><strong><a href="http://bit.ly/NBRGSurveyOnAnnexZ_EN_ISO14971_2012" target="_blank" rel="noopener noreferrer">NBRG Call for Industry Participation &#8211; Survey Understanding Annex Z EN ISO 14971:2012</a></strong></li>
</ul>
<p>If you need help with Risk Management with respect to the IEC 60601 series of Standards, email Leo Eisner directly at <strong><a href="mailto:&#76;&#101;&#111;&#64;&#69;isn&#101;rSa&#102;e&#116;&#121;.com">L&#101;o&#64;E&#105;&#115;&#110;&#101;&#114;S&#97;&#102;&#101;ty&#46;c&#111;&#109;</a></strong>, or call Leo at +1-(503)-244-6151. He is the Principal Consultant of Eisner Safety Consultants (<strong><a title="Link to Eisner Safety Consultants Website" href="http://bit.ly/EisnerSafetyConsultants">bit.ly/EisnerSafetyConsultants</a></strong>).</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NBRG Consensus Document on EN ISO 14971:2012 Is On Its Way MD&#038;M West &#8217;14 Presentation</title>
		<link>https://eisnersafety.com/2014/03/07/nbrg-consensus-document-on-en-iso-149712012-is-on-its-way-mdm-west-14-presentation/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=nbrg-consensus-document-on-en-iso-149712012-is-on-its-way-mdm-west-14-presentation</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Fri, 07 Mar 2014 06:51:26 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[EN ISO 14971]]></category>
		<category><![CDATA[EN ISO 14971:2012]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[ISO 14971]]></category>
		<category><![CDATA[ISO 14971:2007]]></category>
		<category><![CDATA[IVD]]></category>
		<category><![CDATA[IVD Directive]]></category>
		<category><![CDATA[IVDD]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[NBRG]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Notified Body Recommendation Group]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[TEAM-NB]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3663</guid>

					<description><![CDATA[On Tuesday Feb 11, 2014 at the UBM Canon Communications MD&#38;M West Conference Leo Eisner of Eisner Safety Consultants presented this material as the Track Chair for &#8220;Improving Risk Management Strategies And Procedures&#8221;.  He spoke on the proposed Consensus Guidance]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif; font-size: small; line-height: 19px;">On Tuesday Feb 11, 2014 at the UBM Canon Communications MD&amp;M West Conference Leo Eisner of Eisner Safety Consultants presented this material as the Track Chair for &#8220;Improving Risk Management Strategies And Procedures&#8221;.  He spoke on the proposed Consensus Guidance Document on EN ISO 14971:2012 that is currently being drafted by NBRG (the Notified Body Recommendation Group).  EN ISO 14971:2012 was harmonized under the 3 Medical Devices Directives (Medical Device, In Vitro Diagnostic, and Active Implantable Medical Devices Directives) on 30 Aug 2013 and was released with no transition period so there no warning publicly.  So, this has caused a lot of confusion and the confusion still reigns among manufacturers, notified bodies, and others.  Read thru the slide deck to get an idea of the process for this consensus document that will hopefully help all sides in understanding the requirements and being able to come to a reasonable solution for this very confusing matter to many stakeholders.  To help in this process it is highly recommended that you, as a medical device manufacturer, get involved by providing some feedback via an anonymous survey on how your risk management process works and if you follow parts of the EN ISO 14971:2012 process or just the ISO 14971:2007 (or EN ISO 14971:2009 which is equivalent to the ISO 14971:2007 document). </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small; line-height: 19px;"><span id="more-3663"></span>The live link to the survey is on the fourth set of pages on slide deck and is slide 8 of the presentation.  The more participants in the survey the more likely your voices will be heard and we hope this will improve the potential outcome of the process.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small; line-height: 19px;">On 8 February we <strong><a href="http://www.EisnerSafety.com/nbrg-call-for-industry-participation-survey-understanding-annex-z-en-iso-149712012">posted the NBRG letter</a></strong> which was a Call for Industry Participation in the Survey on Understanding Annex Z of EN ISO 14971:2012. </span></p>
<pre><span style="font-family: arial, helvetica, sans-serif; font-size: small; line-height: 19px;">[slideshare id=32021997&amp;doc=mdmwestpresentationonnbrgconsensusdocumentoneniso14971201211feb2014-140306235842-phpapp01&amp;type=d]</span></pre>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NBRG Call for Industry Participation &#8211; Survey Understanding Annex Z EN ISO 14971:2012</title>
		<link>https://eisnersafety.com/2014/02/08/nbrg-call-for-industry-participation-survey-understanding-annex-z-en-iso-149712012/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=nbrg-call-for-industry-participation-survey-understanding-annex-z-en-iso-149712012</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Sat, 08 Feb 2014 21:41:41 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[EN ISO 14971]]></category>
		<category><![CDATA[EN ISO 14971:2012]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[ISO 14971]]></category>
		<category><![CDATA[ISO 14971:2007]]></category>
		<category><![CDATA[IVD]]></category>
		<category><![CDATA[IVD Directive]]></category>
		<category><![CDATA[IVDD]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[NBRG]]></category>
		<category><![CDATA[Notified Body]]></category>
		<category><![CDATA[Notified Body Recommendation Group]]></category>
		<category><![CDATA[Risk Management]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3628</guid>

					<description><![CDATA[This post discusses NBRG’s call to participate in an Industry Survey on Industry’s Practice of Risk Management Process per EN ISO 14971:2012. On 7 February 2014 the Vice Chair of the Notified Body Recommendation Group, Michael Bothe, sent out a letter]]></description>
										<content:encoded><![CDATA[<p>This post discusses NBRG’s call to participate in an Industry Survey on Industry’s Practice of Risk Management Process per EN ISO 14971:2012.</p>
<p>On 7 February 2014 the Vice Chair of the Notified Body Recommendation Group, Michael Bothe, sent out a <a href="http://www.eisnersafety.com/wp-content/uploads/2014/02/NBRG_risk_management_survey_questions_140702_final.docx" target="_blank" rel="noopener noreferrer">letter</a> to industry to ask for their participation in a short survey (about 10 minutes long) to help the Notified Bodies understand what are industry&#8217;s current practices when it comes to conducting Risk Management Process on their medical devices and IVD&#8217;s and how it relates to EN ISO 14971:2012.  As the letter says it is to &#8220;attempt to develop a practical interpretation on how to use and implement Risk Management in the context of the European Medical Devices Directives, more specifically the European version of ISO 14971:2007, as published in EN ISO 14971:2012.&#8221;</p>
<p><span id="more-3628"></span></p>
<p>Please join in on this <strong><a href="https://www.surveymonkey.com/s/Y3CYPNP" target="_blank" rel="noopener noreferrer">survey</a></strong>, as the more participation the more representative the data will be to the Notified Bodies and hopefully this will make for a better Consensus Document on EN ISO 14971:2012 Risk Management Process.  Please complete your survey responses by 21 March 2014.</p>
<p>To find out more about what is going on with this proposed Consensus Document please join me, Leo Eisner as <a href="http://www.eisnersafety.com/leo-eisner-track-chair-at-mdm-west-conf-11-feb-discuss-en-iso-149712012/">the track chair for Improving Risk Management Strategies and Procedures, at the MD&amp;M West conference on Tuesday 11 February 2014</a>, as I discuss how we got to this point and what is hopefully going to culminate in a Consensus Document on Risk Management with regard to EN ISO 14971:2012.</p>
<p>If you have questions about this topic or need help with compliance with your Medical products you can e-mail Leo Eisner at <a href="mailto:&#76;&#101;o&#64;&#69;&#105;&#115;&#110;e&#114;&#83;&#97;&#102;et&#121;.&#99;&#111;&#109;">&#76;e&#111;&#64;&#69;&#105;s&#110;&#101;r&#83;&#97;fet&#121;.com</a> directly or call Leo at 503-244-6151.  Leo is the Principal Consultant of Eisner Safety Consultants.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Leo Eisner Track Chair at MD&#038;M West Conf 11-Feb Discuss EN ISO 14971:2012</title>
		<link>https://eisnersafety.com/2014/01/31/leo-eisner-track-chair-at-mdm-west-conf-11-feb-discuss-en-iso-149712012/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=leo-eisner-track-chair-at-mdm-west-conf-11-feb-discuss-en-iso-149712012</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Fri, 31 Jan 2014 21:29:34 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[14971]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed. Amendment 1]]></category>
		<category><![CDATA[EN 60601-1:06 + Amendment 1:13]]></category>
		<category><![CDATA[EN ISO 14971]]></category>
		<category><![CDATA[EN ISO 14971:2012]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[ISO 14971]]></category>
		<category><![CDATA[Risk Management Process]]></category>
		<category><![CDATA[Risk Management Standard]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3611</guid>

					<description><![CDATA[UBM Canon Communications has graciously asked me to join this year&#8217;s MD&#38;M West Conference with the honor of being the track chair for the Risk, Quality &#38; Validation track on Tues 11 Feb 2014.  We have a great line up that day]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">UBM Canon Communications has graciously asked me to join this year&#8217;s <strong><a href="http://www.canontradeshows.com/expo/west14/" target="_blank" rel="noopener noreferrer">MD&amp;M West</a></strong> Conference with the honor of being the track chair for the <strong><a href="http://www.canontradeshows.com/expo/west14/conference-agenda-quality.html" target="_blank" rel="noopener noreferrer">Risk, Quality &amp; Validation track on Tues 11 Feb 2014</a></strong>.  We have a great line up that day so please come join us.  </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">To kick-off the morning for our track I will be talking briefly on a draft document that NB-MED &amp; COCIR &amp; some other organizations are working on to help clarify what is expected of medical device manufacturers when relying on EN ISO 14971:2012 which is a document that has totally muddied the waters.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;"> <span id="more-3611"></span>I am in direct contact with the authors of this consensus based document and we are working on finalizing what I will be presenting to you at </span><span style="font-family: arial, helvetica, sans-serif; font-size: small;">the conference. So, expect some up to the date information about this document and we may be asking for feedback from industry too.  Stay tuned for any updates to this post too.  I look forward to presenting this material to the conference participants.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">If you need help with the Risk Management File concepts within the IEC 60601 series of Standards, email Leo Eisner directly at <strong><a href="mailto:&#76;e&#111;&#64;&#69;&#105;&#115;&#110;erS&#97;&#102;&#101;ty&#46;c&#111;&#109;">Leo&#64;&#69;isne&#114;&#83;&#97;f&#101;&#116;&#121;.&#99;&#111;m</a></strong>, or call Leo at +1-(503)-244-6151. Leo is the Principal Consultant of Eisner Safety Consultants (<strong><a title="Link to Eisner Safety Consultants Website" href="http://bit.ly/EisnerSafetyConsultants">bit.ly/EisnerSafetyConsultants</a></strong>).</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Status Update on EN 60601-1:06 + A1:13 for EU MDD &#038; Annexes ZA &#038; ZZ</title>
		<link>https://eisnersafety.com/2013/11/21/status-update-on-en-60601-106-a113-for-eu-mdd-annexes-za-zz/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=status-update-on-en-60601-106-a113-for-eu-mdd-annexes-za-zz</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Thu, 21 Nov 2013 08:03:19 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[Amendment 1]]></category>
		<category><![CDATA[Annex ZA]]></category>
		<category><![CDATA[Annex ZA & ZZ]]></category>
		<category><![CDATA[Annex ZZ]]></category>
		<category><![CDATA[CENELEC]]></category>
		<category><![CDATA[Collateral Standard]]></category>
		<category><![CDATA[EFTA]]></category>
		<category><![CDATA[EN 14971]]></category>
		<category><![CDATA[EN 60601-1:06 + A1:13]]></category>
		<category><![CDATA[EN 60601-1:06 + Amendment 1:13]]></category>
		<category><![CDATA[EN ISO 14971]]></category>
		<category><![CDATA[EN ISO 14971:2012]]></category>
		<category><![CDATA[EN60601]]></category>
		<category><![CDATA[EN60601-1]]></category>
		<category><![CDATA[EN60601-1:06 + A1:13]]></category>
		<category><![CDATA[EN60601-1:06 + Amendment 1:13]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[EU Harmonized Standards]]></category>
		<category><![CDATA[EU RoHS]]></category>
		<category><![CDATA[EU RoHS2]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[ISO 14971]]></category>
		<category><![CDATA[List of Harmonized Standards]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[MDD Amendment]]></category>
		<category><![CDATA[MDD Harmonized Standards]]></category>
		<category><![CDATA[MDD Harmonized Standards List]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[OJ]]></category>
		<category><![CDATA[OJEU]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[RoHS]]></category>
		<category><![CDATA[RoHS2]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3531</guid>

					<description><![CDATA[EN 60601-1 (2006) + A1 (2013) status for EU MDD Harmonization &#38; Impact of Annex ZA &#38; ZZ are discussed in this blog. So, you can get to the important areas for you I have split this blog into several]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">EN 60601-1 (2006) + A1 (2013) status for EU MDD Harmonization &amp; Impact of Annex ZA &amp; ZZ are discussed in this blog.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span id="more-3531"></span></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, you can get to the important areas for you I have split this blog into several sections that you can jump too quickly by clicking on the below links:</span></p>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="#Whendid60601A1comeout">When did the IEC 60601-1 A1 come out?</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="#WhatisstatusofEN606011A1">What is the status of the EN 60601-1 A1?</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="#IsEN606011_A1MDDHarmonized">Is EN 60601-1:06 + A1:13 Harmonized under the MDD Yet?</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="#AllOtherEN60601SeriesStds">What about all the other EN 60601 series of standards?</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="#AnnexZA">So, what is Annex ZA about?</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="#AnnexZZ">And what about Annex ZZ?</a></span></li>
</ul>
</ul>
<p><a name="Whendid60601A1comeout"></a></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span style="text-decoration: underline;">When did the IEC 60601-1 A1 come out</span>?</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="http://bit.ly/IEC60601-1A1" target="_blank" rel="noopener noreferrer">Amendment 1 (A1) of IEC 60601-1:2005 (3<sup>rd</sup> ed.)</a> was published last summer on 13 July 2013 and the consolidated edition (<a href="http://bit.ly/ed3dot1IEC60601-1" target="_blank" rel="noopener noreferrer">edition 3.1 = IEC 60601-1:2005 + A1:2012</a>) was published on 20 August 2012.  The consolidated edition is very useful as it shows all the <em><span style="text-decoration: underline;">redlines of the 496 changes that were made for A1</span></em> vs the <a href="http://bit.ly/3rdedIEC60601-1" target="_blank" rel="noopener noreferrer">original 3<sup>rd</sup> ed</a>.</span></p>
<p><a name="WhatisstatusofEN606011A1"></a></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span style="text-decoration: underline;">What is the status of the EN 60601-1 A1?</span></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, for Europe it has taken over a year to get the EN (European Norm) of <a href="http://bit.ly/EN60601-1_2006_A1_2013" target="_blank" rel="noopener noreferrer">A1:2013 to EN 60601-1:2006 (third edition)</a> to be ratified by <a href="http://bit.ly/CENELEC" target="_blank" rel="noopener noreferrer">CENELEC</a> which was on 24 Sept 20013, then it became available for publication (Date of Availability) in Europe on 4 October 2013 and so now it is allowed to be published in Europe and must be implemented or published by all of the EU countries by 24 June 2014.  The only country that I have been able to find it published in is Denmark as a Dansk Standard (DS or in English it would be Danish Standards).  It is <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">DS/EN 60601-1:06/A1:13</a> issued on 15 October 2013.</span></p>
<p><a name="IsEN606011_A1MDDHarmonized"></a></p>
<p><span style="text-decoration: underline; font-size: small; font-family: arial, helvetica, sans-serif;">Is EN 60601-1:06 + A1:13 Harmonized under the MDD Yet?</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The answer is a no, not yet but we are getting pretty close to it occurring.   It hasn’t been Harmonized yet but soon it will be approved as a Harmonized Standard.  <a href="http://www.eisnersafety.com/wp-content/uploads/2013/11/EN-60601-1_06-+-A1_13-Adoption-of-pilot-Annexes-ZZ-ZA-%E2%80%93-EN-60601-1_06-its-A1-13-BT145_DG9198_DV.pdf" target="_blank" rel="noopener noreferrer">This document tells a lot of the story for the history of the Harmonization process for EN 60601-1:06 + A1:13</a>.  This version of the standard has been reviewed and approved for harmonization by the Consultants so its only a matter of publishing it in the <a href="http://bit.ly/OJ_EU" target="_blank" rel="noopener noreferrer">Official Journal of the EU (OJ)</a>.</span></p>
<p><a name="AllOtherEN60601SeriesStds"></a></p>
<p><span style="text-decoration: underline; font-size: small; font-family: arial, helvetica, sans-serif;">What about all the other EN 60601 series of standards?</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If you read thru the <a href="http://www.eisnersafety.com/wp-content/uploads/2013/11/EN-60601-1_06-+-A1_13-Adoption-of-pilot-Annexes-ZZ-ZA-%E2%80%93-EN-60601-1_06-its-A1-13-BT145_DG9198_DV.pdf" target="_blank" rel="noopener noreferrer">document referenced in the previous paragraph</a> you will find there are 41 total 60601 series standards in the pipeline that are all expected to flood out of the <a href="http://bit.ly/OJ_EU" target="_blank" rel="noopener noreferrer">OJ</a> as <a href="http://bit.ly/MDD_Harmonized_Stds_Listing" target="_blank" rel="noopener noreferrer">Harmonized Standards under the MDD</a> by the end of the 1<sup>st</sup> quarter of 2014.  That’s a lot of change to come in a short period of time.  But realize that is not the full series of 60601 standard out there &amp; note there are Joint IEC/ISO projects that are titled 80601 series too.  So, keep your eyes and ears peeled and open to keep up with what will be happening soon.</span></p>
<p><a name="AnnexZA"></a></p>
<p><span style="text-decoration: underline; font-size: small; font-family: arial, helvetica, sans-serif;">So, what is Annex ZA about?</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Annex ZA is a listing of normative (required or mandated) references to international publications with their corresponding European publications.  This is a list of the European &amp; <a href="http://bit.ly/MDD_Harmonized_Stds_Listing" target="_blank" rel="noopener noreferrer">EU Harmonized standards</a>.  This primarily changes most of the IEC and ISO standards that are referenced in <a href="http://bit.ly/ed3dot1IEC60601-1" target="_blank" rel="noopener noreferrer">IEC 60601-1:06 + A1:13 (ed. 3.1)</a> to EN &amp; EN ISO standards for the EN version of the standard.  The standards that change in the base of the standard are marked by (mod.) to indicate the original requirements have been modified by common modifications as noted in the beginning of Annex ZA.  There are some that stay as IEC &amp; ISO standards but most change.  But that isn’t the bombshell.  When <a href="http://bit.ly/IEC60601-1A1" target="_blank" rel="noopener noreferrer">A1:12 of IEC 60601-1:05</a> was published a decision was made to go <em><span style="text-decoration: underline;">from dated references</span></em> for the IEC 60601 series standards (i.e. <a href="http://bit.ly/IEC60601-1-2_2007" target="_blank" rel="noopener noreferrer">IEC 60601-1-2:2007</a>) <em><span style="text-decoration: underline;">to primarily undated references</span></em> (IEC 60601-1-2), unless a specific standard reference didn’t meet the criteria for the change (most changes occurred and a few stayed as dated references).  The primary reason for this change was to make the standards development maintenance process of the whole series of standards (almost 60 standards in the series &amp; growing) easier to update when there was a change in a Particular (i.e. IEC 60601-2-XX) or a Collateral standard (i.e. IEC 60601-1-XX).  <em><span style="text-decoration: underline;">About a year ago under the IEC A1 version of 60601-1 undated references came about but that now has been changed back to dated references in the EN version of the standard (<a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN60601-1:06 +A1:13</a>)</span></em>.  <span style="text-decoration: underline;">This means, as it says at the beginning of Annex ZA, “For dated references, only the (dated) edition cited applies.”</span>  Annex ZA also says “For undated references, the latest edition of the referenced document (including any amendments) applies.”</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, for the IEC series of 60601 standards you currently have the <a title="To learn more about Collateral &amp; Particular Standards read this article" href="http://bit.ly/MDDIRegStratsIEC60601-1_3rd" target="_blank" rel="noopener noreferrer">Collaterals and Particulars</a> being updated or will be updated in the near future (now thru about 2 years from now) to reflect the undated standards references to filter through-out the whole series of IEC 60601 standards.  So, more change to keep an eye out for.  Some people would say you need to have a Master’s degree to keep up with this but you could rely on consultants, like me, as this is one of my many job duties is to keep up-to-date on standards development information so I can keep my client’s informed &amp; up-to-date.</span></p>
<p><a name="AnnexZZ"></a></p>
<p><span style="text-decoration: underline; font-size: small; font-family: arial, helvetica, sans-serif;">And what about Annex ZZ?</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Annex ZZ is a fairly long section clocking in at 19 pages long and part of the focus is on the Risk Management Process of sub-clause 4.2.2 of <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN 60601-1:06 + A1:13</a> as the <a href="http://bit.ly/DS_EN_ISO14971_2012" target="_blank" rel="noopener noreferrer">EN ISO 14971:2012</a> standard is the Harmonized standard most recently called out in the <a href="http://bit.ly/MDD_Harmonized_Stds_Listing" target="_blank" rel="noopener noreferrer">EU MDD Harmonized List of Standards</a> (a voluntary listing but easiest way to prove compliance too) and is a significant modification of <a href="http://bit.ly/ISO14971_2007" target="_blank" rel="noopener noreferrer">ISO 14971:2007</a> with some major changes to it.  So read on for more details with respect to the changes for risk management, among other issues for this Annex ZZ.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Annex ZZ is titled the “Relationship between this European Standard and the Essential Requirements of <a href="http://bit.ly/MDDConsolidated_93_42_EECand2007_47_EC" target="_blank" rel="noopener noreferrer">EU Directive 93/42/EEC on Medical Devices</a>”. Annex ZZ is a means for showing conformance to meeting the parts of the Essential Requirements (ER’s), Annex I, of the <a href="http://bit.ly/MDDConsolidated_93_42_EECand2007_47_EC" target="_blank" rel="noopener noreferrer">MDD under 93/42/EEC as amended by 2007/47/EC</a>, that apply to the standard <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN 60601-1:06 + A1:13</a>.  This standard doesn’t confer compliance with all of the ER’s under the MDD only certain ER’s in whole or in part.  I am repeating the first page text of Annex ZZ in “quotes” below and then writing my commentary, <em>in italics,</em> to explain each section.</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“This European Standard has been prepared under a mandate given to <a href="http://bit.ly/CENELEC" target="_blank" rel="noopener noreferrer">CENELEC</a> by the European Commission and the <a href="http://bit.ly/EURO_FTA" target="_blank" rel="noopener noreferrer">European Free Trade Association</a> to provide a means of conforming to the Essential Requirements given in Annex I of the <a href="http://bit.ly/MDDConsolidated_93_42_EECand2007_47_EC" target="_blank" rel="noopener noreferrer">EC Directives 93/42/EEC as amended by 2007/47/EC</a>.”</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>This means that <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN 60601-1:06 + A1:13</a> Annex ZZ will be the means to prove conformance to the ER’s of the MDD in whole or part based on a mandate to <a href="http://bit.ly/CENELEC" target="_blank" rel="noopener noreferrer">CENELEC</a> from the European Commission &amp; <a href="http://bit.ly/EURO_FTA" target="_blank" rel="noopener noreferrer">EFTA</a>.</em></span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“Once this standard will be cited in the <a href="http://bit.ly/OJ_EU" target="_blank" rel="noopener noreferrer">Official Journal of the European Union</a> under that Directive, compliance with the clauses of this standard given in Table ZZ.1 confers, within the limits of the scope of this standard, a presumption of conformity with the corresponding Essential Requirements (ERs) of that Directive and associated <a href="http://bit.ly/EURO_FTA" target="_blank" rel="noopener noreferrer">EFTA</a> regulations.”</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Once this standard is Harmonized under the <a href="http://bit.ly/MDDConsolidated_93_42_EECand2007_47_EC" target="_blank" rel="noopener noreferrer">MDD</a> (via publication thru the <a href="http://bit.ly/OJ_EU" target="_blank" rel="noopener noreferrer">OJEU</a>) compliance with the clauses of the standard, within the limits of the scope of the standard, cited in Table ZZ.1 confers a presumption of conformity with the corresponding ER’s of the <a href="http://bit.ly/MDDConsolidated_93_42_EECand2007_47_EC" target="_blank" rel="noopener noreferrer">MDD</a> &amp; associated <a href="http://bit.ly/EURO_FTA" target="_blank" rel="noopener noreferrer">EFTA</a> regulations (MDD adopted by EFTA). </em></span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em> </em>“NOTE 1     This standard is intended to be applied in its entirety only. Selected clauses or subclauses may be not applicable due to the specific type of equipment under consideration. It is necessary to understand and apply Clauses 1 to 5. It is also recommended to understand and apply those clauses which contain general requirements related to a specific subclause. Elements of the standard that are not cited in Table ZZ.1 may be relevant for the appropriate fulfilment of certain essential requirements through indirect reference, and for safety and performance aspects of the device, that are not addressed through essential requirements.”</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>You must use the whole standard.  You can’t just pick and choose clauses you need the whole enchilada otherwise not a valid evaluation of the product.  But you may be able to cite &amp; provide justification that certain clauses &amp; sub-clauses don’t apply to your specific device.  Clauses 1 thru 5 of the standard must be applied and understood completely and well.  These clauses include the scope of the standard, the object, how the Particular and Collateral standards of the 60601 series of standards apply, which standards are normative references and how they work (dated vs undated), terminology &amp; definitions, general requirements which includes discussion of &amp; requirements for:</em></span></p>
<ul>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Conditions of the equipment to be tested and analyzed </em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>The Risk Management Process</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Essential Performance</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Expected Service Life</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Equivalent Safety </em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Parts that touch the Patient but aren’t to be marked as Applied Parts</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Single Fault Condition</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Component requirements</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Use of High-Integrity Components</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Power Supply issues</em></span></li>
</ul>
</ul>
</ul>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>And General Requirements for Testing the ME Equipment</em></span></p>
<ul>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Type Tests</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Number of Samples for testing</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Environmental issues</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Test conditions</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Repairs and modifications</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Humidity preconditioning</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Sequence of tests</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Determination of Applied Parts vs Accessible Parts</em></span></li>
</ul>
</ul>
</ul>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em> Also, all clauses that apply general requirements related to specific sub-clauses must be considered &amp; addressed.  Even if there are specific sub-clauses that aren’t cited in the Table ZZ.1 that doesn’t mean they aren’t valid to help meet some of the ER’s even if indirectly &amp; for safety &amp; performance aspects of the device, not addressed through the ER’s.</em></span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“NOTE 2     Where a reference from a clause of this standard to the risk management process is made, the risk management process needs to be in compliance to the <a href="http://bit.ly/MDDConsolidated_93_42_EECand2007_47_EC" target="_blank" rel="noopener noreferrer">MDD (Directive 93/42/EEC amended by 2007/47/EC)</a>. This means that risks have to be reduced &#8220;as far as possible&#8221;, &#8220;to a minimum&#8221;, &#8220;to the lowest possible level&#8221;, &#8220;minimized&#8221; or &#8220;removed&#8221;, according to the wording of the corresponding essential requirement.”</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Where there is a reference made from a clause of the standard <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN 60601-1:06 + A1:13</a> to the risk management process, the risk management process needs to be in compliance with the MDD.  This means that risks have to be reduced according to the specific wording of the corresponding ER.  Such as with the wording “as far as possible”, “to a minimum”, etc.</em></span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“NOTE 3     With respect to note 4 of clause 4.2.2 General requirement for risk management, the manufacturer’s policy for determining <strong>acceptable risk </strong>must be in compliance with essential requirements 1, 2, 5, 6, 7, 8, 9, 11 and 12 of the directive.”</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Note 4 of clause 4.2.2 “General requirement for risk management” states: </em></span></p>
<p style="padding-left: 90px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>“NOTE 4     Where requirements of this standard refer to freedom from unacceptable RISK, acceptability or unacceptability of this RISK is determined by the MANUFACTURER in accordance with the MANUFACTURER’S policy for determining acceptable RISK.”  </em></span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>This infers that the standard <a href="http://bit.ly/ed3dot1IEC60601-1" target="_blank" rel="noopener noreferrer">IEC 60601-1:05 + A1:12</a> requires that Risk is determined by the Manufacturer’s policy for determining acceptable risk which is the Risk Management Process under <a href="http://bit.ly/ISO14971_2007" target="_blank" rel="noopener noreferrer">ISO 14971:2007</a> per the IEC standard (ed. 3.1) but once you get into the MDD &amp; EN Harmonized standard it will be <a href="http://bit.ly/DS_EN_ISO14971_2012" target="_blank" rel="noopener noreferrer">EN ISO 14971:2012</a> based on the conversion done in Annex ZA.</em></span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>So, continuing on &#8212; Risk is determined by the Manufacturer’s policy for determining acceptable risk which is the Risk Management Process under <a href="http://bit.ly/DS_EN_ISO14971_2012" target="_blank" rel="noopener noreferrer">EN ISO 14971:2012</a> for the ER’s 1, 2, 5, 6, 7, 8, 9, 11 &amp; 12 of the MDD.  When you look at Table ZZ.1 you will see in a greyed out area of the top of each ER section for ER’s 1, 2, 5, 6, 7, 8, 9, 11 &amp; 12 there is a note that says “General Guidance note 2 and 3 shall be observed” which infers that you need to follow the risk management process stated in these specific ER’s per <a href="http://bit.ly/DS_EN_ISO14971_2012" target="_blank" rel="noopener noreferrer">EN ISO 14971:2012</a> Annex ZA (for the MDD) which is where all the modifications of the Risk Management standard were made by the EU Commission causing total havoc for the EN ISO version of the standard even though not in the main text of the standard Annex ZA has caused a total mess of what was once a specific standard and now has been jumbled and makes it hard to meet risk management requirements for multiple countries when one of them is the EU and there are other countries involved as <a href="http://bit.ly/ISO14971_2007" target="_blank" rel="noopener noreferrer">ISO 14971</a> &amp; <a href="http://bit.ly/DS_EN_ISO14971_2012" target="_blank" rel="noopener noreferrer">EN ISO 14971</a> are in direct conflict with each other.  You can meet one but not both at the same time from what I have surmised.</em></span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“NOTE 4     References in the clauses 3 to 17 or in the Annexes of this standard specify whether the normative references listed in Clause 2 as cited in Annex ZA are to be applied in whole or in part.”</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Clauses 3 to 17 (the meat of the standard) and the Annexes of the standard <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN 60601-1:06 + A1:13</a> specify whether the mandatory (normative) references listed in Clause 2 (the clause for all the Normative References of the standard), which in the EN version of the standard is replaced by the citations in Annex ZA for clause 2, are to be applied in whole (the whole standard) or in part (a certain portion of the standard) as noted in the standard itself.  </em></span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“NOTE 5     This Annex ZZ is based on Normative References according to Annex ZA, replacing the references in the core text.”</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Annex ZZ of this <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN 60601-1:06 + A1:13</a> standard is based on the Normative references of Annex ZA (Normative Standards that were replaced from IEC &amp; ISO standards to the European EN, EN ISO, &amp; HD standards in the <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN 60601-1:06 + A1:13</a> version of the standard).  Bottom line this means that all the IEC 60601-1:05 + A1:12 normative references are to be replaced by the Annex ZA normative standards references for the <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN 60601-1:06 + A1:13</a> version of the standard.</em></span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“WARNING: Other requirements and other EU Directives and Regulations may be applicable to the product(s) falling within the scope of this standard.”</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>This simply means that the MDD is not the only Directive that may apply.  Some examples of Directives and Regulations that may apply include the following examples:</em></span></p>
<ul>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Restriction of Hazardous Substances (RoHS2) Directive </em></span></li>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>This is coming up for most medical device manufacturers in June of 2014.  That’s not a lot of time to get ready for this process.  If you would like to learn more about this process for the medical device manufacturer please join me in a presentation on RoHS2 for the Medical Device Industry on 17 Dec 2013.</em></span></li>
</ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Waste of Electrical and Electronic Equipment (WEEE) Directive</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Machinery Directive</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Radio and Telecommunications Terminal Equipment (R&amp;TTE) Directive</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Privacy / data protection Clinical data and other personal data Directive</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Regulation on electronic instructions for use of medical devices</em></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Etc.</em></span></li>
</ul>
</ul>
</ul>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><em>Note, that Axon Lawyers has prepared <a href="http://www.eisnersafety.com/wp-content/uploads/2013/11/Axon_Regulation_Chart_Med_Dev_130423.docx" target="_blank" rel="noopener noreferrer">a document for their local RAPS group on the associated Directives that may apply to your EU medical devices</a> and they have been generous to allow all of us to have access to it.  So, thank you Erik Vollebregt for one of your many resources that has helped my clients and I to understand better the implication of the Warning in Annex ZZ of <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN 60601-1:06 + A1:13</a>.</em><em> </em></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, get a copy of the standard <a href="http://bit.ly/DS_EN60601-1_06_A1_13" target="_blank" rel="noopener noreferrer">EN 60601-1:06 + A1:13</a> so you can have access to the important Annex ZA and Annex ZZ.   If you follow the details noted there you should be in good shape. Annex ZZ is a useful tool to make it easier to know what ERs are applicable to the 60601-1 standard and what is expected instead of doing it blindly for so many years without that support. Last week I actually used this table in Annex ZZ very successfully to audit a MDD Technical Files ER checklist and it provided a wealth of information that just made my life a lot easier and will make yours a lot easier too if you need to put an ER Checklist together for your next Technical File or for a Design Dossier too.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">I remember when first working on the IEC based standard that I am a convener of (IEC/ISO 80601-2-58) I was requested to work on the parallel EN standard.  Someone in our Joint Working Group (JWG) suggested that we (the JWG) put together an Annex ZZ but I was later told by some in Europe the 60601 series of standards wasn&#8217;t doing that yet because of some political issues that I was never clear on. So, I guess we finally broke that cycle, many years later, and now many of the 60601 series of standards are slated to go thru this process (41 thru the end of 1<sup>st</sup> quarter of 2014). I think at first probably the more popular ones will get processed and who knows how long it will take to get all of them processed thru.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If your company needs help with edition 3.0 or 3.1 for EN or IEC 60601-1 gap analysis, preparation of the risk management file for these versions of the standard, or training on the Standard, please contact Leo Eisner at: <a href="mailto:L&#101;&#111;&#64;&#69;&#105;s&#110;e&#114;Sa&#102;&#101;t&#121;&#46;co&#109;"><strong>&#76;e&#111;&#64;&#69;i&#115;&#110;&#101;r&#83;&#97;f&#101;&#116;y.&#99;&#111;m</strong></a>.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Sign-up for our monthly newsletter to keep up to date on all our posts.  Go to the upper left hand corner of any page on the site and sign-up to enjoy articles like this.  Make sure to reply to the confirmation e-mail otherwise you won&#8217;t be signed up.</span></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>