<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>FDA Recognized Consensus Standards &#8211; Eisner Safety Consultants</title>
	<atom:link href="https://eisnersafety.com/tag/fda-recognized-consensus-standards/feed/" rel="self" type="application/rss+xml" />
	<link>https://eisnersafety.com</link>
	<description>Regulatory &#38; Safety Experts for Global Medical Device Approvals</description>
	<lastBuildDate>Wed, 29 Jul 2015 18:39:42 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://eisnersafety.com/wp-content/uploads/2025/08/favicon-45x45.png</url>
	<title>FDA Recognized Consensus Standards &#8211; Eisner Safety Consultants</title>
	<link>https://eisnersafety.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Back by Popular Demand &#8211; Wearable Medical Devices – FDA&#8217;s Current Thinking</title>
		<link>https://eisnersafety.com/2015/07/29/back-by-popular-demand-wearable-medical-devices-fdas-current-thinking/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=back-by-popular-demand-wearable-medical-devices-fdas-current-thinking</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Wed, 29 Jul 2015 18:39:42 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[60601-1-11]]></category>
		<category><![CDATA[AAMI HA60601-1-11]]></category>
		<category><![CDATA[Accessories]]></category>
		<category><![CDATA[Accessories Guidance]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[FDA Guidance]]></category>
		<category><![CDATA[FDA Guidance Document]]></category>
		<category><![CDATA[FDA Guidance Documents]]></category>
		<category><![CDATA[FDA Guidances]]></category>
		<category><![CDATA[FDA Mobile Medical Applications Guidance]]></category>
		<category><![CDATA[FDA Recognized Consensus Standards]]></category>
		<category><![CDATA[General Wellness]]></category>
		<category><![CDATA[General Wellness Guidance]]></category>
		<category><![CDATA[HA60601-1-11]]></category>
		<category><![CDATA[Home Use]]></category>
		<category><![CDATA[Home Use Environment]]></category>
		<category><![CDATA[Home Use Environment Guidance]]></category>
		<category><![CDATA[IEC 60601-1-11]]></category>
		<category><![CDATA[IEC 60601-1-11:2010]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[Mobile Medical Applications]]></category>
		<category><![CDATA[Recognized Consensus Standards]]></category>
		<category><![CDATA[Wearable]]></category>
		<category><![CDATA[Wearable Medical Device]]></category>
		<category><![CDATA[Wearable Medical Devices]]></category>
		<category><![CDATA[Wearables]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=4309</guid>

					<description><![CDATA[As this presentation was so well attended in July FX Conferences has decided to rerun this presentation twice in August so those that missed it can obtain this critical information for the Wearable Medical Device industry.  Leo Eisner will be]]></description>
										<content:encoded><![CDATA[<p><strong></strong><a href="http://www.eisnersafety.com/wp-content/uploads/2015/07/Dexcom-SmartWatch-App-2.gif"><img decoding="async" class="alignleft size-full wp-image-4317" style="border: 0px; margin: 2px;" title="Dexcom SmartWatch App 2" src="http://www.eisnersafety.com/wp-content/uploads/2015/07/Dexcom-SmartWatch-App-2.gif" alt="" width="154" height="198" /></a>As this presentation was so well attended in July FX Conferences has decided to rerun this presentation twice in August so those that missed it can obtain this critical information for the Wearable Medical Device industry.  Leo Eisner will be speaking on Medical Device Wearables &amp; FDA&#8217;s Current Thinking with respect to a slew of new guidance documents that could apply to your devices.  This presentation is being offered 2 times in August (Tuesday August 11, 9:30AM Eastern and Wednesday August 12, 2:00PM Eastern).  No travel required to go to this presentation just dial in, download the material &amp; you&#8217;re set to learn from Leo Eisner, an industry expert.  Receive a $50.00 (US$) discount as a special thank you for visiting us at Eisner Safety Consultants (See below).</p>
<p><strong>What&#8217;s it about:</strong> The presentation guides you through many significant issues concerning the design &amp; development of wearable medical devices. Leo will provides an in-depth look at the FDA guidance documents that may apply to your wearables, including the Home Use Environment, Mobile Medical Applications,  Accessories, and General Wellness  guidances among additional broader based ones.</p>
<p>Join us for this audio conference presentation and bring your group up  to speed as Leo guides you through the wide variety of FDA Guidances that may apply to your Wearable Medical Device. <strong>This audio conference will cover:</strong></p>
<ul>
<li>Does the FDA consider your  wearable a medical device?</li>
<li>FDA’s Final Guidances on Mobile Medical Applications &amp; Home Use Environment</li>
<li>The differences between the IEC &amp; AAMI Home Use Environment Medical Electrical Equipment and Systems Standard (60601-1-11) and it&#8217;s impact on the FDA Home Use Guidance</li>
<li>Draft General Wellness &amp; Accessories Guidances</li>
<li>Additional Regulations that may impact your Wearable device beyond the FDA</li>
</ul>
<p><em><strong><a href="http://www.eisnersafety.com/events/" target="_blank" rel="noopener noreferrer">Click here</a></strong></em> for the details on the<em><strong> presentation &amp; discount ($50.00 off regular price)</strong></em> and also some other <strong><em><a href="http://www.eisnersafety.com/Events#Past_Presentations" target="_blank" rel="noopener noreferrer">past presentations</a></em></strong> from FX Conferences that we have presented.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Presentation on Wearable Medical Devices – Current Thinking from FDA</title>
		<link>https://eisnersafety.com/2015/07/07/presentation-on-wearable-medical-devices-current-thinking-from-fda/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=presentation-on-wearable-medical-devices-current-thinking-from-fda</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Tue, 07 Jul 2015 05:24:25 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[60601-1-11]]></category>
		<category><![CDATA[AAMI HA60601-1-11]]></category>
		<category><![CDATA[Accessories]]></category>
		<category><![CDATA[Accessories Guidance]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[FDA Guidance]]></category>
		<category><![CDATA[FDA Guidance Document]]></category>
		<category><![CDATA[FDA Guidance Documents]]></category>
		<category><![CDATA[FDA Guidances]]></category>
		<category><![CDATA[FDA Mobile Medical Applications Guidance]]></category>
		<category><![CDATA[FDA Recognized Consensus Standards]]></category>
		<category><![CDATA[General Wellness]]></category>
		<category><![CDATA[General Wellness Guidance]]></category>
		<category><![CDATA[HA60601-1-11]]></category>
		<category><![CDATA[Home Use]]></category>
		<category><![CDATA[Home Use Environment]]></category>
		<category><![CDATA[Home Use Environment Guidance]]></category>
		<category><![CDATA[IEC 60601-1-11]]></category>
		<category><![CDATA[IEC 60601-1-11:2010]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[Mobile Medical Applications]]></category>
		<category><![CDATA[Recognized Consensus Standards]]></category>
		<category><![CDATA[Wearable]]></category>
		<category><![CDATA[Wearable Medical Device]]></category>
		<category><![CDATA[Wearable Medical Devices]]></category>
		<category><![CDATA[Wearables]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=4296</guid>

					<description><![CDATA[Leo Eisner will be speaking on Medical Device Wearables and the Current Thinking from FDA with respect to myriad of new guidance documents that may apply to your devices.  This presentation is being offered 2 times in July (Tuesday July]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><img decoding="async" src="http://www.fxconferences.com/App_Themes/Glass_FXT/images/logo.jpg" alt="" width="171" height="54" />Leo Eisner will be speaking on Medical Device Wearables and the Current Thinking from FDA with respect to myriad of new guidance documents that may apply to your devices.  This presentation is being offered 2 times in July (Tuesday July 21, 10:00AM Eastern and Thursday July 23, 1:00PM Eastern).  The best thing is you don&#8217;t have to travel to go to this presentation just dial in, download the material and you are set to learn from an industry expert.  As a special thank you for visiting us at Eisner Safety Consultants you can get a $50.00 (US$) discount.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Sign up now to take away some really valuable information in this fast moving industry.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><strong>What&#8217;s it about:</strong> This audio conference presentation guides attendees through many of the significant issues concerning the development of wearable medical devices. Leo provides an in-depth look at the guidance documents that may apply to your wearables, including the Mobile Medical Applications, Home Use Environment, General Wellness, and Accessories guidances among additional broader based ones.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Join us for this audio conference presentation and ease your regulatory stress as Leo guides you through the wide variety of FDA Guidances that may apply to your Wearable Medical Device. <strong>This audio conference will cover:</strong></span></p>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Is your wearable a medical device per the FDA?</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">FDA’s Final Mobile Medical Applications &amp; Home Use Environment Guidances</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The differences between the IEC &amp; AAMI versions of 60601-1-11 (Home Use Environment Medical Electrical Equipment and Systems) Standard and how it impacts your use of the Home Use Guidance</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Draft General Wellness &amp; Accessories Guidances</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Other Regulations that can apply to Wearables outside of FDA</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Understanding which Recognized Consensus Standards may apply to your device</span></li>
</ul>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">To <em><strong>find out more about the presentation &amp; discount ($50.00 off regular price) <a href="http://www.eisnersafety.com/events/">click here</a></strong></em> for the details and also some other <strong><em><a href="http://www.eisnersafety.com/Events#Past_Presentations">past presentations</a></em></strong> that Eisner Safety Consultants have presented for FX Conferences previously.</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDA Extends AAMI ES 60601-1 Transition Date to 31 Dec &#8217;13 &#038; Other Important Changes &#8211; Recognition Lists 031/032</title>
		<link>https://eisnersafety.com/2013/08/06/fda-extends-aami-es-60601-1-transition-date-to-31-dec-13-other-important-changes-recognition-lists-031032/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fda-extends-aami-es-60601-1-transition-date-to-31-dec-13-other-important-changes-recognition-lists-031032</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Tue, 06 Aug 2013 10:37:09 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[031]]></category>
		<category><![CDATA[032]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[AAMI]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[AAMI ES60601-1/C1]]></category>
		<category><![CDATA[Amendment 1]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[CDRH]]></category>
		<category><![CDATA[Collateral Standard]]></category>
		<category><![CDATA[consens]]></category>
		<category><![CDATA[Consensus Standard]]></category>
		<category><![CDATA[consensus standards]]></category>
		<category><![CDATA[Consensus Standards List 031]]></category>
		<category><![CDATA[Consensus Standards List 032]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[FDA Guidance]]></category>
		<category><![CDATA[FDA Recognition List 031]]></category>
		<category><![CDATA[FDA Recognition List 032]]></category>
		<category><![CDATA[FDA Recognized Consensus Standards]]></category>
		<category><![CDATA[FDA's Recognition List 031]]></category>
		<category><![CDATA[FDA's Recognition List 032]]></category>
		<category><![CDATA[Guidance Document]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[iec 60601]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[IEC60601-1-11]]></category>
		<category><![CDATA[List 031]]></category>
		<category><![CDATA[List 032]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[medical electrical equipment]]></category>
		<category><![CDATA[NRTL]]></category>
		<category><![CDATA[osha]]></category>
		<category><![CDATA[OSHA Nationally Recognized Test Lab Program]]></category>
		<category><![CDATA[premarket submissions]]></category>
		<category><![CDATA[Recognized Consensus Standard]]></category>
		<category><![CDATA[Recognized Consensus Standard Database]]></category>
		<category><![CDATA[Recognized Consensus Standards]]></category>
		<category><![CDATA[Recognized Consensus Standards List 031]]></category>
		<category><![CDATA[Recognized Consensus Standards List 032]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3444</guid>

					<description><![CDATA[The big news in the IEC 60601-1, 3rd ed. world today is the US National Standard that is in the FDA&#8217;s Recognized Consensus Standards Lists [Now is ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text) &#8211; Recognition List #:]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">The big news in the IEC 60601-1, 3rd ed. world today is the US National Standard that is in the FDA&#8217;s Recognized Consensus Standards Lists [Now is ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text) &#8211; <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">Recognition List #: 031</a></strong>, Recognition # 5-77] has had it&#8217;s transition date moved from June 30, 2013 to December 31, 2013.  So, if you are about to submit to the FDA for a pre-market submission you still may have a choice to use the IEC 60601-1, 2<sup>nd</sup> edition version of the standard instead of the US National Version of IEC 60601-1, 3<sup>rd</sup> ed.  You still may want to use the US National Version that is based on IEC  60601-1, 3<sup>rd</sup> ed. but now you have a choice again.  So, as of January 1, 2014 all your pre-market submissions to the FDA that rely on the US National version of the IEC 60601-1, 3rd ed. standard should be using this version of the standard (ANSI/AAMI ES60601-1:2005/(R)2012&#8230;, <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">Rec List #: 031</a></strong>, Rec #: 5-77).  Note, that use of the FDA&#8217;s Recognized Consensus Standards is voluntary but if you don&#8217;t use it realize the burden of proof is higher on your shoulders to prove to the FDA you meet the requirements they are expecting from you. </span></p>
<p><span id="more-3444"></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">From what I have determined the change in transition date is based on that OSHA’s NRTL (Nationally Recognized Test Laboratories) Program will be aligning with the FDA in terms of this standard and will hopefully be by the end of this year, if not sooner, they will be able to approve NRTL Test Labs to the US National Version of IEC 60601-1, 3<sup>rd</sup> ed. which probably will be ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text).  FDA has been intending to, and I hope they do, come out with a guidance document for premarket submissions of medical electrical equipment and what their expectations are for applying the US National Version of IEC 60601-1, 3<sup>rd</sup> edition.  Also, about 1-1/2 months ago FDA announced their concern about cyber-security for medical devices and hospital networks and so they issued a Safety Communication on June 13, 2013 to medical device manufacturers, hospitals, medical device user facilities, health care IT &amp; procurements staff; &amp; biomedical engineers; and <strong><a href="http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/UCM356190.pdf" target="_blank" rel="noopener noreferrer">they issued a draft guidance document on the issue</a></strong> on June 14, 2013.  To coordinate all these activities, draft guidance documents, and agencies FDA decided to extend the transition period for the US National version of IEC 60601-1, 3<sup>rd</sup> ed. equivalent.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">The IEC 60601 series of standards that FDA has Listed in the Recognized Consensus Standards Listing and some of the ISO 80601 series of standards that FDA has listed are updated in <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">List 031</a></strong> with this new transition date, unless it is a brand new standard being published on the List for the first time, along with other changes that were ready to be published.  The Cyber-security standards are listed in <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19020/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">Recognition List 032</a></strong> and are all new listings to the List of Recognized Consensus Standards.  There were many other changes with these Recognition Lists <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">031</a></strong> &amp; <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19020/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">032</a></strong> which will officially be published in the Federal Register as of 6 August 2013 and the changes will officially be effective then but have already been issued prior to August 6, 2013 in the FDA&#8217;s Recognized Consensus Database. (Either one or two days prior).</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Below is a summary of the more critical changes, from my perspective, for <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">List 031</a></strong>.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">New Standards Added to the <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">FDA&#8217;s Recognition List 031</a></strong> (Table 2 of List 031) of significance are:</span></p>
<table style="width: 509px;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Recognition Number</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Title of Standard (Abbreviated)</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Standard Ref Number / Date of Issue</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Blog Comments</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">5-75</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical devices&#8211;Symbols to be used w/ med dvc labels, labeling, &amp; info to be supplied&#8211;Part 1</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/ISO 15223-1 / 2012</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Added the US National Version in addition to the ISO version which is Recognition # 5-73</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">17-11</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-10: Particular requirements for basic safety &amp; essential performance of nerve &amp; muscle stimulators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-10 Edition 2.0 / 2012-06</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Newer version of std.  Transition date set for Dec 31, 2013. So, on Jan 1, 2014 this ver. of the std will only be accepted.  Rec # 17-5, IEC 60601-2-10:1987 + Amendment 1 2001 accepted up til Dec 31, 2013. Note, the transition date info is not mentioned in Rec # 17-5.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-251</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med elect equip&#8211;Part 2-63: Particular requirements for basic safety &amp; essential performance of dental extra-oral X-ray equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-63 Edition 1.0 / 2012-09</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Brand new std added to Recognized Consensus Standards.  Since there isn’t a previous ver. of the std there is no transition date.  This means this std is effective on the date of publication of this Listing in the Federal Register which is 6 August 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-252</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med elect equip&#8211;Part 2-65: Particular requirements for basic safety &amp; essential performance of dental intra-oral X-ray equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-65 Edition 1.0 / 2012-09</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Same comments as above Rec. # 12-251.</span></td>
</tr>
</tbody>
</table>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">There were also modifications to the List of Recognized Stds (Table 1 of List 031) of some importance.  The 60601 related standards were updated to align with the transition period of ANSI/AAMI ES60601-1 std along with other changes of importance as noted below.</span></p>
<table style="width: 509px;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Recognition Number</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">(New)</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Title of Standard (Abbreviated)</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Standard Ref Number / Date of Issue</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Blog Comments</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">1-82</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-13: Particular requirements for basic safety &amp; essential performance of anaesthetic systems</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-13 Edition 3.1 / 2009-08</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Newer version of std.  Transition date set for Dec 31, 2013. So, on Jan 1, 2014 this ver. of the std will only be accepted.  Rec # 1-61, IEC 60601-2-13:2003-05 accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">1-88</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-12: Particular requirements for basic safety &amp; essential performance of lung ventilators &#8212; Critical care ventilators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ISO 80601-2-12 First Edition / 2011-04-15</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Newer version of std (previously was an IEC std and now an ISO std as it was done by a Joint Working group of IEC &amp; ISO committee members).  Transition date set for Dec 31, 2013. So, on Jan 1, 2014 this ver. of the std will only be accepted.  Rec # 1-60, IEC 60601-2-12:2001-10 accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">2-198</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Biological eval of med dvcs&#8211;Part 12: Sample prep &amp; ref mat’ls</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/ISO 10993 / 12:2012</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Newer US National Version of ISO 10993-12. Withdrawn the ANSI/AAMI/ISO 10993-12:2007 version of the std, Rec. # 2-135</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">2-174</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">(Published 03/16/2012)</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Biological eval of med dvcs—Part 10: Tests for irritation &amp; skin sensitization</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ISO 10993-10 Third Edition / 2010-08-01</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Withdrew older version of ISO version of the std. Refer to Rec. # 2-152, ISO 10993-10: 2002 / Amendment 1:2006</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">3-115</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-34: Particular requirements for basic safety &amp; essential performance of Invasive Blood Pressure Monitoring Euip</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-34 Edition 3.0 / 2011-05</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Newer version of std.  Transition date set for Dec 31, 2013. So, on Jan 1, 2014 this ver. of the std will only be accepted.  Rec # 3-38, IEC 60601-2-34:2000-10 accepted up til Dec 31, 2013 but it’s Rec # 3-38 has been deleted from the FDA Database.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">4-187</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-18: Particular requirements for basic safety &amp; essential performance of endoscopic equip</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-18 Edition 3.0 / 2009-08</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">FDA’s notice says transition period extended but when checked the database the transition period ended June 30, 2013 and is referring only to IEC 60601-1:2001 (Edition 2) and ANSI / AAMI ES60601-1:2005 which doesn’t correlate with the other listings. It seems like the database either hasn’t been updated for this item or got goofed up as of the evening of Aug 5<sup>th</sup>.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">5-53</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip &#8211; Part 1-2: General requirements for basic safety &amp; essential performance &#8211; Collateral std: Electromagnetic compat &#8211; Requirements &amp; tests</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-1-2 Edition 3.0  / 2007-03</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Transition period extended for this IEC version of the std from June 30, 2013 to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 5-34, IEC 60601-1-2, Edition 2:2001 + Amendment 1:2004 accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">5-54</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip &#8211; Part 1-2: General requirements for basic safety &amp; essential performance &#8211; Collateral std: Electromagnetic compat &#8211; Requirements &amp; tests</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-1-2 Edition 3.0  / 2007 (R)2012</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Transition period extended for US National version  (ANSI/AAMI/IEC) of the std from June 30, 2013 to Dec 31, 2013 and this std reaffirmed in 2012.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 5-35, ANSI/AAMI/IEC 60601-1-2, Edition 2:2001 + Amendment 1:2004 accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">5-76</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip &#8211; Part 1-8: General requirements for basic safety &amp; essential performance &#8211; Collateral std: General requirements, tests, &amp; guidance for alarm systems in med elect equip &amp; med elect systems</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-1-8 Edition 2.1 / 2012-11</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Withdrew Rec # 5-55 (IEC 60601-1-8 Ed.1:2003) and replaced with Rec #5-76 and extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 5-55 accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-300</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-21: Particular requirements for basic safety &amp; essential performance of infant radiant warmers</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-21 Edition 2.0 / 2009-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-300 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-9 (IEC 60601-2-21:1996 + A1:2000) accepted up til Dec 31, 2013.  In the extension note section of Rec # 6-300 there are a couple typos as they refer to 60601-2-19 instead of 60601-2-21.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-298</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-19: Particular requirements for basic safety &amp; essential performance of infant incubators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-19 Edition 2.0 / 2009-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-298 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-29 (IEC 60601-2-19 A1:1996-10) accepted up til Dec 31, 2013.  In the extension note section of Rec # 6-298 there are a couple typos as they refer to ANSI/AAMI/IEC 60601-2-19:2009 instead of IEC60601-2-19:2009-02</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-299</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-20: Particular requirements for basic safety &amp; essential performance of infant  radiant warmers</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-20 Edition 2.0 / 2009-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-299 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-32 (IEC 60601-2-20 A1:1996-10) accepted up til Dec 31, 2013.  In the extension note section of Rec # 6-299 there are a couple typos as they refer to ANSI/AAMI/IEC 60601-2-19:2009 instead of IEC60601-2-20:2009-02</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-227</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-21 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-227 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-146 (IEC 60601-2-21:1996 + A1:2000) accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-228</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical Electrical Equipment&#8211;Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-2 Edition 5.0 / 2009-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-228 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-46 (IEC 60601-2-2:2006) accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-229</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgery equipment and high frequency surgical accessories</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-2 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-229 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-46 (IEC 60601-2-2:2006) accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-230</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical Electrical Equipment&#8211;Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-19 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-230 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-29 (IEC 60601-2-19 A1:1996-10) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-231</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical Electrical Equipment&#8211;Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-20 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-231 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-32 (IEC 60601-2-20 A1:1996-10) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-233</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment &#8212; Part 2-52: Particular requirements for basic safety and essential performance of medical beds</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-52 Edition 1.0 / 2009-12</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-233 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-182 (IEC 60601-2-38:1996 + A1:1999) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-234</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-50 Edition 2.0 / 2009-03</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Change in contact person only.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-235</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical Electrical Equipment&#8211;Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-50 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Same as above comment.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">9-80</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment &#8212; Part 2-16: Particular requirements for basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-16 Third edition / 2008</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Withdrew Rec # 9-60 [IEC 60601-2-16 Edition 3.0 2008-04] and Rec # 9-63 [IEC 60601-2-16 (Third edition&#8211;2008)] replaced with Rec #9-80 and extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-60 &amp; 9-63 accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">9-61</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-18 Edition 3.0 / 2009-08</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #9-61 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-42 (IEC 60601-2-18:1996 + A1:2000) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">9-81</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-16: Particular requirements for basic safety and essential performance of hemodialysis, hemodiafiltration and hemofiltration equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/ IEC 60601-2-16 / 2012</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #9-81 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-72 (IEC 60601-2-16:1998) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">9-62</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-2: Particular requirements for the basic safety and essential performance of frequency</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">surgical equipment and high frequency surgical accessories</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-2 Edition 5.0 / 2009-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #9-62 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-46 (IEC 60601-2-2:2006) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">9-64</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgery equipment and high frequency surgical accessories</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-2 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #9-64 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-46 (IEC 60601-2-2:2006) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-201</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-54 Edition 1.0 / 2009-06</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-201 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-34 (IEC 60601-2-7 Second Edition 1998-02) &amp; Rec # 12-127 (IEC 60601-2-32 Edition 1.0 1994) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-254</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-8: Particular requirements for the basic safety and essential performance of therapeutic</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">X-ray equipment operating in the range 10 kV to 1 MV</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-8 Edition 2.0 / 2010-11</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-254 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-54 (IEC 60601-2-8 1999-04) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-255</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-11 Edition 3.0 / 2013-01</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-255 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-133 (IEC 60601-2-11:1997 + A1:2004) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-202</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">procedures</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-43 Edition 2.0 / 2010-03</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-202 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-63 (IEC 60601-2-43 Edition 1.0 2000) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-256</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">tomography</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-44 Edition 3.1 / 2012-09</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-254 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-203 or 12-120 (IEC 60601-2-44 2002-11) accepted up til Dec 31, 2013.  Not clear if one or both are applicable.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-204</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-28 Edition 2.0 / 2010-03</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-204 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-126 (IEC 60601-2-28 Edition 1.0 1993) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-205</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">equipment&#8211;Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">physiotherapy equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-5 Edition 3.0 / 2009-07</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-205 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-147 (IEC 60601-2-5 Edition 2.0 2000) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-206</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">equipment&#8211;Part 2-1: Particular requirements for the basic safety and essential performance of electron</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">accelerators in the range 1 MeV to 50 MeV</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-1 Edition 3.0 / 2009-10</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-206 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-152 (IEC 60601-2-1 1998 + A1:2002) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-207</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnostic</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-33 Edition 3.0 / 2010-03</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-207 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-189 (IEC 60601-2-33 Edition 2.2 2008) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-208</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">diagnostic laser equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-22 Third Edition / 2007-05</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-208 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-197 (IEC 60601-2-22 Edition 2.0 1995) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-209</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-37 Edition 2.0 / 2007-08</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-209 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-198 (IEC 60601-2-37:2004 + A2:2005) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-210</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">equipment&#8211;Part 1-3: General requirements for basic safety and essential performance&#8211;Collateral Standard: Radiation protection in diagnostic X-ray equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-1-3 Edition 2.0 / 2008-01</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-210 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-199 (IEC 60601-1-3 1994) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-211</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment Part 2-29: Particular requirements for the basic safety and essential performance of</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">radiotherapy simulators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-29 Edition 3.0 / 2008-06</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-211 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-200 (IEC 60601-2-29 Edition 2.0 1999) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-256</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography CORRIGENDUM 1</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-44 Third edition / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Withdrew Rec # 12-224  [IEC 60601-2-2-44 2002-11] and Rec # 12-250 [IEC 60601-2-2-44 2002-11] replaced with Rec #12-256 and extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-224 &amp;12-250 accepted up til Dec 31, 2013.  Unable to totally confirm that Rec #’s 12-224 &amp; 12-250are linked to IEC 60601-2-44 2002-11].</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-236</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-45: Particular requirements for the safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-45 Edition 3.0 / 2011-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-236 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-178 (IEC 60601-2-45 Edition 2.0 2001) accepted up til Dec 31, 2013. </span></td>
</tr>
</tbody>
</table>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">In a future blog post we may discuss <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19020/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">Recognition List 032</a></strong> and the Cyber-security standards.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">If you have any questions or if you would like our assistance with regard to these standards please feel free to contact us at Leo&#64;E&#105;s&#110;e&#114;S&#97;f&#101;&#116;y.&#99;&#111;m.</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDA &#038; EU MDD / AIMDD / IVDD Updated Standards Lists</title>
		<link>https://eisnersafety.com/2013/01/31/fda-eu-mdd-aimdd-ivdd-updated-standards-lists/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fda-eu-mdd-aimdd-ivdd-updated-standards-lists</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Thu, 31 Jan 2013 20:57:35 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Active Implantable Medical Devices Directive]]></category>
		<category><![CDATA[AIMDD]]></category>
		<category><![CDATA[AIMDD Harmonized Standards]]></category>
		<category><![CDATA[AIMDD Harmonized Standards List]]></category>
		<category><![CDATA[CDRH]]></category>
		<category><![CDATA[CENELEC]]></category>
		<category><![CDATA[consensus standards]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[EU]]></category>
		<category><![CDATA[EU Harmonized Standards]]></category>
		<category><![CDATA[European Commission]]></category>
		<category><![CDATA[European Union]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[FDA Consensus Standards]]></category>
		<category><![CDATA[FDA Recognized Consensus Standards]]></category>
		<category><![CDATA[FDA Standards]]></category>
		<category><![CDATA[Federal Register]]></category>
		<category><![CDATA[harmonised standards]]></category>
		<category><![CDATA[harmonized standards]]></category>
		<category><![CDATA[implantable medical device]]></category>
		<category><![CDATA[IVDD Harmonized Standards]]></category>
		<category><![CDATA[IVDD Harmonized Standards List]]></category>
		<category><![CDATA[List of Harmonized Standards]]></category>
		<category><![CDATA[MDD]]></category>
		<category><![CDATA[MDD Harmonized Standards]]></category>
		<category><![CDATA[MDD Harmonized Standards List]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Directive]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[official journal of the european union]]></category>
		<category><![CDATA[Recognized Consensus Standards]]></category>
		<category><![CDATA[Regulatory Focus]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3043</guid>

					<description><![CDATA[Recently the FDA (United States) has released its latest List of Recognized Consensus Standards &#38; the EU (European Union) has released updated lists of Harmonized Standards for the MDD (Medical Device Directive), the AIMDD (Active Implantable Medical Device Directive), and]]></description>
										<content:encoded><![CDATA[<p>Recently the FDA (United States) has released its latest List of Recognized Consensus Standards &amp; the EU (European Union) has released updated lists of Harmonized Standards for the MDD (Medical Device Directive), the AIMDD (Active Implantable Medical Device Directive), and the IVDD (In-Vitro Diagnostic Directive).</p>
<p><span id="more-3043"></span></p>
<p>On 15 Jan &#8217;13 the FDA issued a notice in Federal Register for the <strong><a href="https://www.federalregister.gov/articles/2013/01/15/2013-00605/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized#h-13" target="_blank" rel="noopener noreferrer">Recognition List # 30</a></strong>.  The notice in the Federal Register said: &#8220;FDA maintains the Agency&#8217;s current list of FDA recognized consensus standards in a <strong><a href="http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfStandards/search.cfm" target="_blank" rel="noopener noreferrer">searchable database</a></strong>&#8230;FDA will incorporate the modifications and minor revisions described in this notice into the database and, upon publication in the Federal Register, this recognition of consensus standards will be effective. FDA will announce additional modifications and minor revisions to the list of recognized consensus standards, as needed, in the Federal Register once a year, or more often, if necessary.&#8221;</p>
<p>Other resources that you can find out more about this subject:</p>
<p style="padding-left: 30px;"><strong><a href="http://www.raps.org/focus-online/news/news-article-view/article/2724/dozens-of-medical-device-standards-adopted-re-affirmed-by-fda.aspx" target="_blank" rel="noopener noreferrer">RAPS Regulatory Focus article</a></strong> of 15 Jan 2013</p>
<p style="padding-left: 30px;"><strong><a href="http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/Standards/default.htm" target="_blank" rel="noopener noreferrer">CDRH&#8217;s Standards Program / Standards Management Staff webpage</a></strong></p>
<p> On 24 Jan &#8217;13 the Official Journal of the European Union published updated lists of Harmonized Standards under their respective Directives for the:</p>
<p style="padding-left: 30px;"><strong><a href="http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:C:2013:022:0007:0029:EN:PDF" target="_blank" rel="noopener noreferrer">MDD</a></strong> (OJ published updated list of Harmonized Standards) and the <strong><a href="http://ec.europa.eu/enterprise/policies/european-standards/harmonised-standards/medical-devices/index_en.htm" target="_blank" rel="noopener noreferrer">consolidated list of Harmonized Standards*</a></strong></p>
<p style="padding-left: 30px;"><strong><a href="http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:C:2013:022:0001:0006:EN:PDF" target="_blank" rel="noopener noreferrer">AIMDD</a></strong> (OJ published updated list of Harmonized Standards) and the <strong><a href="http://ec.europa.eu/enterprise/policies/european-standards/harmonised-standards/implantable-medical-devices/index_en.htm" target="_blank" rel="noopener noreferrer">consolidated list of Harmonized Standards*</a></strong></p>
<p style="padding-left: 30px;"><a href="http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:C:2013:022:0030:0034:EN:PDF" target="_blank" rel="noopener noreferrer"><strong>IVDD</strong></a> (OJ published updated list of Harmonized Standards) and the <strong><a href="http://ec.europa.eu/enterprise/policies/european-standards/harmonised-standards/iv-diagnostic-medical-devices/index_en.htm" target="_blank" rel="noopener noreferrer">consolidated list of Harmonized Standards*</a></strong></p>
<p>* &#8211; All of the consolidated lists of Harmonized Standards have a note that indicate that these are for reference only and are not the legal documents.  A repeat of the note for these Directives is below:</p>
<p style="padding-left: 30px;">&#8220;The summary list hereunder is a compilation of the references of harmonised standards which have been generated by the HAS (Harmonised standards) database. This IT application HAS automates the process of the publication of the references of harmonised standards in the Official Journal of the European Union. Although the list is updated regularly, it may not be complete and it does not have any legal validity; only publication in the Official Journal gives legal affect.&#8221;</p>
]]></content:encoded>
					
		
		