<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IEC 60601-1-1 &#8211; Eisner Safety Consultants</title>
	<atom:link href="https://eisnersafety.com/tag/iec-60601-1-1/feed/" rel="self" type="application/rss+xml" />
	<link>https://eisnersafety.com</link>
	<description>Regulatory &#38; Safety Experts for Global Medical Device Approvals</description>
	<lastBuildDate>Fri, 14 Jun 2013 06:29:34 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://eisnersafety.com/wp-content/uploads/2025/08/favicon-45x45.png</url>
	<title>IEC 60601-1-1 &#8211; Eisner Safety Consultants</title>
	<link>https://eisnersafety.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>IEC 60601-1, 3rd ed. related standards changes &#038; new Interpretation Sheet 3</title>
		<link>https://eisnersafety.com/2013/06/14/iec-60601-1-3rd-ed-related-standards-changes-new-interpretation-sheet-3/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=iec-60601-1-3rd-ed-related-standards-changes-new-interpretation-sheet-3</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Fri, 14 Jun 2013 06:29:34 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[510(k)]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[60601-1-11]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[AAMI]]></category>
		<category><![CDATA[AAMI ES 60601-1 2005/A1 2012]]></category>
		<category><![CDATA[AAMI ES 60601-1:05/A1:12]]></category>
		<category><![CDATA[AAMI ES 60601-1:2005 / A1:2012]]></category>
		<category><![CDATA[AAMI ES 60601-1:2005/A1:2012]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[AAMI ES60601-1/C1]]></category>
		<category><![CDATA[Amendment 1]]></category>
		<category><![CDATA[Amendment 1 to IEC 60601-1:2005]]></category>
		<category><![CDATA[ANSI]]></category>
		<category><![CDATA[ANSI.AAMI/IEC]]></category>
		<category><![CDATA[ANSI/AAMI ES 60601-1:2005/A1:2012]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[ES 60601-1:2005 / A1:2012]]></category>
		<category><![CDATA[ESC]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[IEC 60601-1 + A1]]></category>
		<category><![CDATA[IEC 60601-1 3rd ed]]></category>
		<category><![CDATA[IEC 60601-1-1]]></category>
		<category><![CDATA[IEC 60601-1-4]]></category>
		<category><![CDATA[IEC60601]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[international electrotechnical commission]]></category>
		<category><![CDATA[Interpretation Sheet]]></category>
		<category><![CDATA[Interpretation Sheet 3]]></category>
		<category><![CDATA[IS3]]></category>
		<category><![CDATA[Labeling]]></category>
		<category><![CDATA[Labels]]></category>
		<category><![CDATA[Marking]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[medical electrical equipment]]></category>
		<category><![CDATA[Risk Management File]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3397</guid>

					<description><![CDATA[IEC 60601-1, 3rd ed. has been out for about 7 years now and there have been lots of changes within the IEC 60601 series of standards to align with 3rd edition.  Last summer Amendment 1 (A1) came out and if]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">IEC 60601-1, 3<sup>rd</sup> ed. has been out for about 7 years now and there have been lots of changes within the IEC 60601 series of standards to align with 3<sup>rd</sup> edition.  </span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span id="more-3397"></span>Last summer Amendment 1 (A1) came out and if you haven’t yet you should start learning about those changes as they will be impacting you sooner rather than later (sign-up for an FX Conferences recording of my recent presentation on <strong><a title="Click here to get to the area of the webpage for instructions to get a discount &amp; then click on the A1 presentation to order it" href="http://www.eisnersafety.com/events/#Past_Presentations" target="_blank" rel="noopener noreferrer">A1 of IEC 60601-1 and its’ impact on users</a></strong>, follow the instructions to get a $50.00 discount, and sign up for the presentation titled “IEC 60601–1, 3rd Edition, Amendment 1 and its Impact on Users”) and also A1 can help you as it will reduce the amount of Risk Management File work you need to do for a product safety certification or approval. There are about 25 less Risk Management File requirements when using A1 vs using 3<sup>rd</sup> ed.  To understand the differences and changes of A1 it is highly recommended that you get the IEC 60601-1 edition 3.1 (consolidated) edition as that shows you where all the changes are to the text vs 3<sup>rd</sup> ed.  Note, when you submit for testing thru a test lab you will either want to use either edition 3.1 or 3<sup>rd</sup> ed. but you can’t mix and match as that would not work well and any CB scheme certified lab, among most other labs, will not mix and match requirements as it gets messy quickly.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, what are the current changes to the standards related to alignment with 3<sup>rd</sup> ed. &amp; the new Interpretation Sheet?  Let’s start with the standards.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The updates are actually withdrawal of two standards that have been embedded into 3<sup>rd</sup> ed. when it was released (i.e. IEC 60601-1-1, 2<sup>nd</sup> edition – Medical Electrical Systems &amp; IEC 60601-1-4 Programmable Electrical Medical Systems) and so the 2<sup>nd</sup> ed. aligned standards needed to be withdrawn as 2<sup>nd</sup> edition of IEC 60601-1 has been withdrawn since the publication of 3<sup>rd</sup> edition back at the end of 2005.  The withdrawal report to IEC for IEC 60601-1-1, Edition 2.0 (now in IEC 60601-1, 3rd ed. in clause 16) covered the following 3 points, and it is the same circumstances for IEC 60601-1-4, edition 1.1 (1<sup>st</sup> ed. + A1) (now in IEC 60601-1, 3rd ed. in clause 14):</span></p>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">IEC 60601-1 Ed. 2.2 (IEC 60601-1:1988+A1:1991+A2:1995) was withdrawn in 2005, yet those who want to use it have been able to do so for the past seven years.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">IEC 60601-1 Ed. 2.2 makes normative reference to a number of supporting standards that have been revised or superseded, yet users have been able to find the versions they need to implement Edition 2.2.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">With the changes made in Amendment 1 to IEC 60601-1:2005, there are substantive technical differences between this collateral standard and its respective clause in IEC 60601-1 Ed. 3.1. Therefore, this document can no longer be considered to represent the generally accepted state of the art.</span></li>
</ul>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Let’s move onto the Interpretation Sheet 3 (or IS3) for IEC 60601-1 3<sup>rd</sup> edition and also for edition 3.1 or 3<sup>rd</sup> edition + A1.  It is the 3<sup>rd</sup> interpretation sheet issued since IEC 60601-1, 3<sup>rd</sup> edition has been issued.  IS3 is a clarification of the requirement for sub-clause 13.1.2, 4<sup>th</sup> dashed line which the sub-clause is titled “Emissions, deformation of ENCLOSURE or exceeding maximum Temperature”.  The requirement of concern is:</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“The following HAZARDOUS SITUATIONS shall not occur;”</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“- ….”</span><br />
<span style="font-size: small; font-family: arial, helvetica, sans-serif;">“-     temperatures of ME EQUIPMENT parts that are not APPLIED PARTS but are likely to be touched, exceeding the allowable values in Table 23 when measured and adjusted as described in 11.1.3;”  (This is the fourth dashed line of 13.1.2)</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, this requirement is saying that this situation should not occur (following HAZARDOUS SITUATIONS) if there is a part that isn’t an APPLIED PART (An APPLIED PART is a part of the device that in NORMAL USE necessarily comes into physical contact with the PATIENT for the device to perform its function.  So, a part other than an APPLIED PART) that is likely to be touched that exceeds the temperature limits of Table 23 (Allowable max temperatures for ME EQUIPMENT parts that are likely to be touched) in the temperature test method described in sub-clause 11.3.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The IS3 gives an alternative route to meeting the above requirement by stating the following:</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“This is clarified by the following:</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The above requirement is regarded as fulfilled in accordance with Subclause 4.5 for temperatures at the surfaces of the enclosure, if the following conditions are fulfilled:</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">− The maximum allowed temperature on OPERATOR accessible surfaces in SINGLE FAULT CONDITION is 105 °C; and</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">− the instructions for use contain a warning that, under some SINGLE FAULT CONDITIONS, the temperature of: (indicate the surface of concern) could get hot and there is a possible RISK of a burn if touched, and</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">− if the RISK ANALYSIS demonstrates a need for a warning symbol on the ENCLOSURE, safety sign ISO 7010-W018 (<a href="http://www.eisnersafety.com/wp-content/uploads/2013/06/Hot-touch-warning.png"><img decoding="async" class="alignnone size-full wp-image-3402" title="Hot touch warning" src="http://www.eisnersafety.com/wp-content/uploads/2013/06/Hot-touch-warning.png" alt="" width="40" height="38" /></a> ) shall be used on or adjacent to the hot spot on the ENCLOSURE; and</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">− the RISK ASSESSMENT demonstrates that the temperature attained in the SINGLE FAULT CONDITION is acceptable, and</span></p>
<p style="padding-left: 60px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">− the RISK ASSESSMENT demonstrates that applying the alternative RISK CONTROL measures in this Interpretation Sheet results in a RESIDUAL RISK that is comparable to the RESIDUAL RISK resulting from applying the requirement of the standard.</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">NOTE 1 This Interpretation Sheet is intended to be used with both Edition 3.0 and Edition 3.1 of IEC 60601-1.</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">NOTE 2 An example of an analysis that demonstrates an adequately low probability of occurrence of HARM is shown below.&#8221;</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">To access this IS3 for free please go to the <strong><a title="Download the IS3 document for free from the IEC website" href="http://webstore.iec.ch/corrigenda/iec60601-1-i3%7Bed3.0%7Db.pdf" target="_blank" rel="noopener noreferrer">IEC website link</a></strong>.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If you need assistance with this or other issues, please contact us at <strong><a href="mailto:&#76;e&#111;&#64;&#69;i&#115;&#110;erSaf&#101;t&#121;.c&#111;&#109;">&#76;&#101;o&#64;&#69;&#105;snerSafe&#116;y.co&#109;</a></strong>.</span></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
