<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IEC60601-1 2nd ed. &#8211; Eisner Safety Consultants</title>
	<atom:link href="https://eisnersafety.com/tag/iec60601-1-2nd-ed/feed/" rel="self" type="application/rss+xml" />
	<link>https://eisnersafety.com</link>
	<description>Regulatory &#38; Safety Experts for Global Medical Device Approvals</description>
	<lastBuildDate>Fri, 22 Feb 2013 21:55:34 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://eisnersafety.com/wp-content/uploads/2025/08/favicon-45x45.png</url>
	<title>IEC60601-1 2nd ed. &#8211; Eisner Safety Consultants</title>
	<link>https://eisnersafety.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Which 60601-1, 3rd ed. Standard Applicable for FDA?</title>
		<link>https://eisnersafety.com/2013/02/22/which-60601-1-3rd-ed-standard-applicable-for-fda/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=which-60601-1-3rd-ed-standard-applicable-for-fda</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Fri, 22 Feb 2013 21:55:34 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[510(k)]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[AAMI]]></category>
		<category><![CDATA[AAMI ES 60601-1]]></category>
		<category><![CDATA[AAMI ES 60601-1 2005/A1 2012]]></category>
		<category><![CDATA[AAMI ES 60601-1:05/A1:12]]></category>
		<category><![CDATA[AAMI ES 60601-1:2005]]></category>
		<category><![CDATA[AAMI ES 60601-1:2005 / A1:2012]]></category>
		<category><![CDATA[AAMI ES 60601-1:2005/A1:2012]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[AAMI ES60601-1/C1]]></category>
		<category><![CDATA[Amendment 1]]></category>
		<category><![CDATA[ANSI/AAMI ES 60601-1:2005/A1:2012]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[CDRH]]></category>
		<category><![CDATA[consensus standards]]></category>
		<category><![CDATA[declarations of conformity]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[fda database]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[iec 60601]]></category>
		<category><![CDATA[IEC 60601-1 2nd ed.]]></category>
		<category><![CDATA[IEC 60601-1 2nd edition]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 2nd ed.]]></category>
		<category><![CDATA[IEC60601-1 2nd edition]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[medical electrical equipment]]></category>
		<category><![CDATA[premarket submissions]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[Transition Period]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3179</guid>

					<description><![CDATA[I have been asked in a variety of flavors if 3rd ed. of IEC 60601-1:2005 and/or 3rd ed. + Amendment 1 (A1):2012 will be required by the FDA and when? The answer isn’t exactly yes or no.  The end of]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">I have been asked in a variety of flavors if 3<sup>rd</sup> ed. of IEC 60601-1:2005 and/or 3<sup>rd</sup> ed. + Amendment 1 (A1):2012 will be required by the FDA and when? The answer isn’t exactly yes or no. </span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The end of the transition period for 2<sup>nd</sup> ed. of IEC 60601-1 is June 30, 2013.  By July 1, 2013 I hope you will be using the 3<sup>rd</sup> ed. based standard for your FDA premarket submissions declarations of conformity.  Are you ready for this transition period and where is the transition information located?</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span id="more-3179"></span>The answer is that the IEC version of 60601-1 isn’t a Recognized Consensus standard after the end of the transition period for 2<sup>nd</sup> ed. of IEC 60601-1.  FDA will allow the 2nd ed. of IEC 60601-1:1988 + A1: 1991 + A2:95 (Recognition Number 5-4, Recognition List #013) up til the end of the transition period of June 30, 2013 but the transition period isn’t noted in this entry of the Recognized Consensus Standards list.  So, where do you suppose it is located?  One could search for a very long time and not come up with the answer, as the FDA database for Recognized Consensus Standards is not flexible when it comes to search terms.  You need to know to search for the US national version of the standard, which is the AAMI ES version.  Also, the entries for the 3<sup>rd</sup> ed based US national version of IEC 60601-1 vs. the 3<sup>rd</sup> ed. + A1 national version of IEC 60601-1 aren’t in the database the same way.  One is in the database as ‘ES60601-1’ and the other is ‘ES 60601-1’.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, as of now you can start to use the ANSI/AAMI ES 60601-1:2005/(R)2012 and C1:2009/(R)2012, including the A2:2010/(R)2012 (Consolidated Text), <em>Medical electrical equipment &#8211; Part 1: General requirements for basic safety and essential performance </em>[Recognition Number 5-71, Recognition List #029] OR ANSI/AAMI ES 60601-1:2005/A1:2012 [Recognition Number 5-74, Recognition List #030] <strong><a href="http://www.eisnersafety.com/fda-eu-mdd-aimdd-ivdd-updated-standards-lists/" target="_blank" rel="noopener noreferrer">Recognition list #030 was issued on 15 Jan ’13</a></strong>.  Up to and thru June 30, 2013 you can also use the 2<sup>nd</sup> ed. of IEC 60601-1 [Recognition Number 5-4, Recognition List #013].  In the Extent of Recognition section of both ES 60601-1 standards you will find a sub-section titled “Transition:” which states:</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“FDA recognition of <strong><span style="text-decoration: underline;">Edition 2:1988</span></strong> (A1:1991+A2:1995) <strong><span style="text-decoration: underline;">of IEC 60601-1</span> </strong>is <strong><span style="text-decoration: underline;">hereby superseded</span></strong> <strong><span style="text-decoration: underline;">by recognition of ANSI/AAMI ES60601-1:2005</span></strong>, Medical Electrical Equipment &#8211; Part 1: General requirements </span><br />
<span style="font-size: small; font-family: arial, helvetica, sans-serif;"> for basic safety and essential performance. <strong><span style="text-decoration: underline;">FDA will accept declarations of conformity</span></strong>, in support of <strong><span style="text-decoration: underline;">premarket submissions</span></strong>, <strong><span style="text-decoration: underline;">to Edition 2:1988</span></strong> (A1:1991+A2:1995) of IEC 60601-1 <strong><span style="text-decoration: underline;">until June 30, 2013</span></strong>. <strong><span style="text-decoration: underline;">After</span></strong> this <strong><span style="text-decoration: underline;">transitional period</span></strong>, <strong><span style="text-decoration: underline;">declarations of conformity to Edition 2:1988</span></strong>(A1:1991+A2:1995) of the standard <strong><span style="text-decoration: underline;">will not be accepted</span></strong>.”</span><br />
<span style="font-size: small; font-family: arial, helvetica, sans-serif;">Note, the text of the transition for both of the ES 60601-1 standards is the same.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If you company needs support dealing with the IEC 60601 series of standards, working with the Safety Agencies or the National Regulatory bodies (US, Canada, Europe, and around the world) for a product submission and approval <strong><a href="http://www.eisnersafety.com/about_us/" target="_blank" rel="noopener noreferrer">we can provide you with regulatory, product safety, standards compliance, quality system </a><a href="http://www.eisnersafety.com/about_us/" target="_blank" rel="noopener noreferrer">services and more</a></strong>.  Please feel free to contact us at <strong><a href="mailto:&#76;&#101;&#111;&#64;E&#105;&#115;n&#101;rSaf&#101;&#116;&#116;y&#46;&#99;o&#109;">L&#101;&#111;&#64;&#69;isnerS&#97;f&#101;tt&#121;.&#99;om</a></strong> or 503-244-6151.   </span></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
