<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>OSHA Nationally Recognized Test Lab Program &#8211; Eisner Safety Consultants</title>
	<atom:link href="https://eisnersafety.com/tag/osha-nationally-recognized-test-lab-program/feed/" rel="self" type="application/rss+xml" />
	<link>https://eisnersafety.com</link>
	<description>Regulatory &#38; Safety Experts for Global Medical Device Approvals</description>
	<lastBuildDate>Wed, 07 Jan 2015 07:35:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://eisnersafety.com/wp-content/uploads/2025/08/favicon-45x45.png</url>
	<title>OSHA Nationally Recognized Test Lab Program &#8211; Eisner Safety Consultants</title>
	<link>https://eisnersafety.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>OSHA NRTL’s approved for AAMI ES 60601-1 3rd edition + Amendment 1 (or edition 3.1)</title>
		<link>https://eisnersafety.com/2015/01/07/osha-nrtls-approved-for-aami-es-60601-1-3rd-edition-amendment-1-or-edition-3-1/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=osha-nrtls-approved-for-aami-es-60601-1-3rd-edition-amendment-1-or-edition-3-1</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Wed, 07 Jan 2015 07:35:35 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[AAMI]]></category>
		<category><![CDATA[AAMI ES 60601-1 + A1]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[Home Healthcare Environments]]></category>
		<category><![CDATA[Home Use]]></category>
		<category><![CDATA[Home Use Environment]]></category>
		<category><![CDATA[Home Use Med Dvcs]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[IEC60601-1-11]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[Nationally Recognized Test Labs]]></category>
		<category><![CDATA[osha]]></category>
		<category><![CDATA[OSHA Nationally Recognized Test Lab Program]]></category>
		<category><![CDATA[OSHA NRTL]]></category>
		<category><![CDATA[UL 60601-1]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=4010</guid>

					<description><![CDATA[&#160; This post discusses NRTL’s approved for AAMI ES 60601-1 3rd ed. + A1 &#38; can issue NRTL Marks vs which are in process. There has been a lot of activity from OSHA with respect to the NRTL (Nationally Recognized]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><a href="http://www.eisnersafety.com/wp-content/uploads/2015/01/Shareasimage-small-OSHA-Approved-NRTLs-to-MEd-Dvc-Cat-Image.png"><img fetchpriority="high" decoding="async" class="alignleft size-medium wp-image-4018" title="Shareasimage (small) OSHA &amp; Approved NRTL's to MEd Dvc Cat Image" src="http://www.eisnersafety.com/wp-content/uploads/2015/01/Shareasimage-small-OSHA-Approved-NRTLs-to-MEd-Dvc-Cat-Image-300x213.png" alt="" width="300" height="213" /></a></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">This post discusses NRTL’s approved for AAMI ES 60601-1 3</span><sup style="font-family: arial, helvetica, sans-serif;">rd</sup><span style="font-family: arial, helvetica, sans-serif; font-size: small;"> ed. + A1 &amp; can issue NRTL Marks vs which are in process.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">There has been a lot of activity from OSHA with respect to the NRTL (Nationally Recognized Test Laboratory) program of late for medical device testing.  UL 60601-1 is still an approved standard that an approved NRTL can issue a NRTL test mark too but a few of the NRTL’s have now been recently approved to issue a NRTL Mark to AAMI ES 60601-1 3<sup>rd</sup> edition + Amendment 1.  Once UL formally announces that UL 60601-1 will be withdrawn will OSHA take steps to withdraw that standard from their list of Approved Standard so that could a long time from now as I have not heard any word that UL wants to withdraw the UL 60601-1 (equivalent to 2nd ed. of IEC 60601-1 + US National Deviations).  Note, from several of my past blog posts OSHA has only allowed approved NRTL’s to use the standard AAMI ES 60601-1 3<sup>rd</sup> edition with Amendment 1 or with additional amendments to ‘future-proof’ the standard (<strong><a href="http://www.EisnerSafety.com/can-an-osha-nrtl-certify-to-ansiaami-es60601-12005r2012-with-amendments-yet/" target="_blank" rel="noopener noreferrer">Can an OSHA NRTL Certify to ANSI/AAMI ES60601-1:2005/(R)2012 with Amendments Yet?</a></strong> &amp; <strong><a href="http://www.EisnerSafety.com/qa-on-osha-nrtl-for-aami-es-60601-1-3rd-ed-a1/" target="_blank" rel="noopener noreferrer">Q&amp;A on OSHA NRTL for AAMI ES 60601-1 3rd ed. + A1</a></strong> &amp; <strong><a href="http://www.EisnerSafety.com/osha-to-add-aami-es-60601-1-to-list-of-appropriate-nrtl-program-test-standards/" target="_blank" rel="noopener noreferrer">OSHA to Add AAMI ES 60601-1 to &#8216;List of Appropriate&#8217; NRTL Program Test Standards</a></strong>).  OSHA did not like the standard AAMI ES 60601-1 3<sup>rd</sup> edition by itself without the amendment and that is why it took so long before OSHA allowed a US based version of 3<sup>rd</sup> ed. of IEC 60601-1.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The best place to confirm if a Safety Test Lab is an approved NRTL for the medical device standard AAMI ES 60601-1 3<sup>rd</sup> edition + Amendment 1 is by confirming the notifications published in the <strong><a href="https://www.federalregister.gov/" target="_blank" rel="noopener noreferrer">US Federal Register</a></strong>.  The second best place is the <strong><a href="https://www.osha.gov/dts/otpca/nrtl/" target="_blank" rel="noopener noreferrer">OSHA NRTL website for the specifically approved NRTL</a></strong>.  The reason why the NRTL website is my second source is it seems like it takes some time (i.e. several weeks to a month or so) for OSHA to update the site to get the most recently approved standards listed for the specific NRTL for the specific NRTL webpage. </span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, which labs are currently approved to issue a NRTL Mark for the standard AAMI ES 60601-1 3<sup>rd</sup> edition + Amendment 1?<br />
</span></p>
<table style="width: 443px;" border="1" cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td valign="top" width="172"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Notice in Federal Register on:</span></td>
<td valign="top" width="271"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Safety Test House Name</span></td>
</tr>
<tr>
<td valign="top" width="172"><strong><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="http://www.regulations.gov/#!documentDetail;D=OSHA-2007-0039-0019" target="_blank" rel="noopener noreferrer">October 20, 2014</a></span></strong></td>
<td valign="top" width="271"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Intertek Testing Services NA, Inc. (also known as ETL)</span></td>
</tr>
<tr>
<td valign="top" width="172"><strong><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="http://www.regulations.gov/#!documentDetail;D=OSHA-2006-0028-0019" target="_blank" rel="noopener noreferrer">October 20, 2014</a></span></strong></td>
<td valign="top" width="271"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">MET Laboratories, Inc.</span></td>
</tr>
<tr>
<td valign="top" width="172"><strong><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="http://www.regulations.gov/#!documentDetail;D=OSHA-2009-0025-0016" target="_blank" rel="noopener noreferrer">October 27, 2014</a></span></strong></td>
<td valign="top" width="271"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Underwriters Laboratories, Inc.</span></td>
</tr>
<tr>
<td valign="top" width="172"><strong><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="http://www.regulations.gov/#!documentDetail;D=OSHA-2009-0026-0056" target="_blank" rel="noopener noreferrer">December 22, 2014</a></span></strong></td>
<td valign="top" width="271"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Curtis-Straus, LLC</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 13px;"><br />
</span></p>
<p>&nbsp;</p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">There are a couple other NRTL’s that are in process of being approved for this standard too but are not at the Final Decision Federal Register Announcement stage quite yet.  They include:</span></p>
<table style="width: 443px;" border="1" cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td valign="top" width="104"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Notice in Federal Register on:</span></td>
<td valign="top" width="140"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Safety Test House Name</span></td>
<td valign="top" width="199"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Status</span></td>
</tr>
<tr>
<td valign="top" width="104"><strong><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="http://www.regulations.gov/#!documentDetail;D=OSHA-2007-0043-0008" target="_blank" rel="noopener noreferrer">October 3, 2014</a></span></strong></td>
<td valign="top" width="140"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">TÜV SÜD America, Inc.</span></td>
<td valign="top" width="199"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">OSHA announced the application for expansion of its as a Nationally Recognized Testing Laboratory (NRTL) and presents the Agency&#8217;s preliminary finding to grant the application to add AAMI ES60601-1 to TÜV SÜD America, Inc.’s Scope of recognition</span></td>
</tr>
<tr>
<td valign="top" width="104"><strong><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="http://www.regulations.gov/#!documentDetail;D=OSHA-2006-0040-0015" target="_blank" rel="noopener noreferrer">October 27, 2014</a></span></strong></td>
<td valign="top" width="140"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">SGS North America, Inc.</span></td>
<td valign="top" width="199"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Same as above but for SGS North America, Inc. and for multiple standards including AAMI ES 60601-1.</span></td>
</tr>
<tr>
<td valign="top" width="104"><strong><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a href="http://www.regulations.gov/#!documentDetail;D=OSHA-2013-0016-0004" target="_blank" rel="noopener noreferrer">December 22, 2014</a></span></strong></td>
<td valign="top" width="140"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Nemko-CCL, Inc. (Salt Lake City, Utah)</span></td>
<td valign="top" width="199"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Same as above but for Nemko-CCL, Inc. and for ANSI/AAMI ES60601-1: 2005/(R)2012 (the more recent publications for OSHA have used this reference vs AAMI ES 60601-1) and UL 60601-1.</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, once the 2nd list of NRTL’s are Recognized for the AAMI ES 60601-1, for 3<sup>rd</sup> + Amendment 1 these NRTL’s will finally be authorized to allow their clients, after passing the applicable testing for their product(s), to place a US NRTL Test Mark on their client product(s). The first list in this blog post those NRTL’s are currently authorized to allow their clients, after passing the applicable testing for their product(s), to place a US NRTL Test Mark on their client product(s) to the ANSI/AAMI ES60601-1:2005/2012.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">One additional piece of OSHA NRTL news is that I, Leo Eisner of Eisner Safety Consultants proposed to OSHA, on June 30, 2014, adding all current US based standards related to the US national standards of IEC 60601 series (AAMI standards).  If you would like to read the letter with this list that was sent in to OSHA <strong><a href="http://www.eisnersafety.com/wp-content/uploads/2015/01/Request-to-OSHA-to-Add-Standards-to-NRTL-Approval-List-for-60601-series-of-US-Stds-30June20141.pdf" target="_blank" rel="noopener noreferrer">Read it here</a></strong>.   Based on the letter I sent into OSHA a <strong><a href="http://www.regulations.gov/#!documentDetail;D=OSHA-2013-0012-0011" target="_blank" rel="noopener noreferrer">Federal Register Notice was issued on Nov 6, 2014</a></strong> that proposed adding in all the standards I proposed (&amp; a couple other non-related standards), with a close of comments date of December 8, 2014.  The list of proposed standards is noted below from part of the Federal Register Notice:</span></p>
<table border="1" cellpadding="0">
<thead>
<tr>
<td colspan="2">
<div>
<p align="center">Table 1—(Partial List of) Test Standards OSHA Is Proposing To Add to the NRTL Program&#8217;s List of Appropriate Test Standards</p>
</div>
</td>
</tr>
<tr>
<td>
<p align="center"><strong>Test standard</strong></p>
</td>
<td>
<p align="center"><strong>Test standard title</strong></p>
</td>
</tr>
</thead>
<tbody>
<tr>
<td>AAMI HA60601-1-11</td>
<td>Medical Electrical Equipment—Part 1-11: General requirements for basic safety and essential performance—Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare.</td>
</tr>
<tr>
<td>AAMI 60601-2-2</td>
<td>Medical electrical equipment—Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgery equipment and high frequency surgical accessories.</td>
</tr>
<tr>
<td>AAMI 60601-2-4</td>
<td>Medical electrical equipment—Part 2-4: Particular requirements for basic safety and essential performance of cardiac defibrillators.</td>
</tr>
<tr>
<td>AAMI 60601-2-16</td>
<td>Medical electrical equipment,—Part 2-16: Particular requirements for basic safety and essential performance of hemodialysis, hemodiafiltration and hemofiltration equipment.</td>
</tr>
<tr>
<td>AAMI 60601-2-19</td>
<td>Medical Electrical Equipment—Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators.</td>
</tr>
<tr>
<td>AAMI 60601-2-20</td>
<td>Medical Electrical Equipment—Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators.</td>
</tr>
<tr>
<td>AAMI 60601-2-21</td>
<td>Medical Electrical Equipment—Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers.</td>
</tr>
<tr>
<td>AAMI 60601-2-25</td>
<td>Medical electrical equipment—Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs.</td>
</tr>
<tr>
<td>AAMI 60601-2-27</td>
<td>Medical electrical equipment—Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment.</td>
</tr>
<tr>
<td>AAMI 60601-2-47</td>
<td>Medical electrical equipment—Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems.</td>
</tr>
<tr>
<td>AAMI 60601-2-50</td>
<td>Medical Electrical Equipment—Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment.</td>
</tr>
<tr>
<td>AAMI 80601-2-30</td>
<td>Medical electrical equipment—Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers.</td>
</tr>
<tr>
<td>AAMI 80601-2-58</td>
<td>Medical Electrical Equipment—Part 2-58: Particular requirements for the basic safety and essential performance of lens removal devices and vitrectomy devices for ophthalmic surgery.</td>
</tr>
</tbody>
</table>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">There were 2 comments on this specific notice.  1 comment was not related to the standards that I proposed and the other was specific to the list of standards I referred to.  Curtis-Straus believes that the detailed list should not be added to the NRTL list of Approved Standards because the general standard ANSI/AAMI ES 60601-1:2005/2012(R) refers to the Particular and Collateral Standards of the 60601-1 series (</span><strong><a style="font-family: arial, helvetica, sans-serif; font-size: small;" href="http://www.eisnersafety.com/wp-content/uploads/2015/01/Curtis-Straus_Comments_on_Proposed_Modification_to_List_of_Appropriate_NRTL_Program_Test_Standards.pdf" target="_blank" rel="noopener noreferrer">letter attached</a></strong><span style="font-family: arial, helvetica, sans-serif; font-size: small;">) but they miss the point that not all of these standards have been developed and maintained by a US based SDO (Standards Development Organization such as ANSI, AAMI, UL, etc.) which is an OSHA requirement. But I requested these standards specifically because my OSHA contact indicated that no IEC 60601 series standards that aren&#8217;t specifically US based standards (i.e. developed by a US based SDO) can be used to issue a US NRTL Test Mark.  So, if these US based medical device standard(s) are approved by OSHA the approved NRTL&#8217;s for those standards would be able to issue a US NRTL Mark for those standards once OSHA approves the Test Labs for this list of standards.  I do not know based on Curtis-Straus&#8217;s comments what OSHA will do with this list now.  I will check into the issue and report back on this topic.  </span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If you need additional support for ANSI/AAMI ES60601-1: 2005/(R)2012 or IEC 3rd edition + A1 email Leo Eisner at <strong><a href="mailto:L&#101;&#111;&#64;E&#105;&#115;ner&#83;afet&#121;.&#99;&#111;m">&#76;e&#111;&#64;Ei&#115;&#110;e&#114;&#83;&#97;&#102;&#101;ty.co&#109;</a></strong>, or call Leo at +1-(503)-244-6151. Leo is the Principal Consultant of Eisner Safety Consultants (<strong><a title="Link to Eisner Safety Consultants Website" href="http://bit.ly/EisnerSafetyConsultants">bit.ly/EisnerSafetyConsultants</a></strong>).</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Can an OSHA NRTL Certify to ANSI/AAMI ES60601-1:2005/(R)2012 with Amendments Yet?</title>
		<link>https://eisnersafety.com/2014/04/15/can-an-osha-nrtl-certify-to-ansiaami-es60601-12005r2012-with-amendments-yet/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=can-an-osha-nrtl-certify-to-ansiaami-es60601-12005r2012-with-amendments-yet</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Tue, 15 Apr 2014 18:18:23 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[AAMI]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[CDRH]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[Home Healthcare Environments]]></category>
		<category><![CDATA[Home Use]]></category>
		<category><![CDATA[Home Use Environment]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[Nationally Recognized Test Labs]]></category>
		<category><![CDATA[NRTL]]></category>
		<category><![CDATA[osha]]></category>
		<category><![CDATA[OSHA Nationally Recognized Test Lab Program]]></category>
		<category><![CDATA[OSHA NRTL]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3765</guid>

					<description><![CDATA[This article discusses OSHA&#8217;s release of ANSI/AAMI ES60601-1:2005/(R)2012 + Amendments &#38; timing of @ least 1 NRTL’s authorization to use it. On 27 March 2014 OSHA announced thru a Federal Register Final Notice that they are incorporating new test standards]]></description>
										<content:encoded><![CDATA[<p><a href="http://www.eisnersafety.com/wp-content/uploads/2014/04/ES60601-1ed3andA1.jpg"><img decoding="async" class="alignleft size-full wp-image-3769" style="margin-top: -2px; margin-bottom: -2px;" title="ES60601-1ed3andA1" src="http://www.eisnersafety.com/wp-content/uploads/2014/04/ES60601-1ed3andA1.jpg" alt="" width="149" height="195" /></a></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">This article discusses OSHA&#8217;s release of ANSI/AAMI ES60601-1:2005/(R)2012 + Amendments &amp; timing of @ least 1 NRTL’s authorization to use it.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><span>On 27 March 2014 OSHA announced thru a <strong><a href="https://www.federalregister.gov/articles/2014/03/27/2014-06807/revision-of-oshas-policy-for-incorporating-new-test-standards-into-the-list-of-appropriate-nrtl#t-1" target="_blank" rel="noopener noreferrer">Federal Register Final Notice</a></strong> that they are incorporating new test standards into the <strong><a href="https://www.osha.gov/dts/otpca/nrtl/list_standards.html" target="_blank" rel="noopener noreferrer">list of ‘Appropriate NRTL* Program Test Standards’</a></strong>.  With this</span></span><span style="font-size: small; font-family: arial, helvetica, sans-serif;"> announcement they have officially added the US medical electrical standard “<a href="http://my.aami.org/store/detail.aspx?id=606011" target="_blank" rel="noopener noreferrer"><strong>ANSI/AAMI ES60601-1:2005/(R)2012 Medical electrical equipment, Part 1: General requirements for basic safety and essential performance </strong><strong>(with amendments)</strong></a>” as an ‘Appropriate NRTL Program Test Standard’.  The ES60601-1 weblink goes to the AAMI online store for the standard for your convenience. This announcement is something that many of us in the medical device industry have been waiting for about 8+ years &#8211; since the publication of IEC 60601-1:2005 in Dec 2005.  </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">*NRTL = Nationally Recognized Testing Laboratory. </span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span id="more-3765"></span></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">This version of the standard is currently the US National Version of IEC 60601-1:2005 + Amendment 1:2012 (A1) + Corrigendums + Interpretation Sheets + US National Deviations.  When I checked with my contact at OSHA he indicated that OSHA tries to make references to the ‘Appropriate NRTL Program Test Standards’ so as to “Future Proof” it, that is to say they make the reference fairly broad so if there are updates to the standard, like a new amendment, they still would be able to list the Standard as an “Appropriate Standard”.  He said it this way ‘I was not involved with writing the FR notice, but I suspect it was written that way to future proof the approval of the standard.  When OSHA approves a standard, we typically don&#8217;t publish a new FR notice when the standard is revised or a new edition is published.  Had we announced the specific amendment numbers it would have locked us into that specific version.  By being a bit more generic, it allows AAMI to revise and update the standard and we do not need to publish a new FR notice every time it is updated.  The important thing for us was we were not recognizing the original issuance of the AAMI standard, only A1 and later.’ As I mentioned in my previous posts on this subject of January 11, 2014 (<strong><a href="http://www.EisnerSafety.com/qa-on-osha-nrtl-for-aami-es-60601-1-3rd-ed-a1/" target="_blank" rel="noopener noreferrer">Q&amp;A on OSHA NRTL for AAMI ES 60601-1 3rd ed. + A1</a></strong>) and of November 25, 2013 (<strong><a href="http://www.Eisnersafety.com/osha-to-add-aami-es-60601-1-to-list-of-appropriate-nrtl-program-test-standards/" target="_blank" rel="noopener noreferrer">OSHA to Add AAMI ES 60601-1 to &#8216;List of Appropriate&#8217; NRTL Program Test Standards</a></strong>) OSHA never liked the original version of US version of IEC 60601-1:2005 (3<sup>rd</sup> edition) but instead once A1 came out with its 496 changes (for the IEC standard)  that made the standard easier to use and more sensible that made all the difference in the world to OSHA. </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;"><span style="font-family: arial, helvetica, sans-serif;">So, if you want to get a US NRTL Mark on your product to this standard you will have to update to 3<sup>rd</sup> ed. + A1 when there is a NRTL that is approved for this standard as you will see an estimated time frame later in this article.  With FDA you have some time before 3<sup>rd</sup> edition with A1 is required (stayed tune for further details in a future post) as you can use 3<sup>rd</sup> edition without A1 until August 1, 2016 (as noted in FDA’s Recognized Consensus Standards List under <strong><a href="https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfstandards/detail.cfm?standard__identification_no=32131" target="_blank" rel="noopener noreferrer">Recognition Number 5-78</a></strong> Supplemental Information Sheet (SIS) “ANSI/AAMI ES60601-1:2005/(R)2012 and C1:2009/(R)2012 and A2:2010/(R)2012”).  You are also allowed to used 3<sup>rd</sup> edition</span></span><span style="font-size: small; font-family: arial, helvetica, sans-serif;"> with A1 with FDA using <strong><a href="https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfstandards/detail.cfm?standard__identification_no=32116" target="_blank" rel="noopener noreferrer">Recognition Number 5-77</a></strong>.  A reminder that the <strong><a href="https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfstandards/Search.cfm" target="_blank" rel="noopener noreferrer">Recognized Consensus Standards</a></strong> are not mandated to be used and are voluntary.  But I try to remind my clients if the Agency is used to reviewing to that Standard you are typically better off using this standard, even though voluntary, than starting from scratch and recreating the wheel.  It was invented a long time ago so why put yourself thru all this extra work?</span></p>
<h2><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Are We There Yet OSHA?</span></h2>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">When I checked in with my contact on 27 March about the <strong><a href="https://www.federalregister.gov/articles/2014/03/27/2014-06807/revision-of-oshas-policy-for-incorporating-new-test-standards-into-the-list-of-appropriate-nrtl#t-1" target="_blank" rel="noopener noreferrer">Federal Register Final Notice</a></strong> he indicated ‘that at least one lab has applied for recognition to AAMI ES 60601-1’ and that their ‘…policy is not to disclose who or how many have applied as we do not want to contribute to any business advantage or strategy that any NRTL may have or want.’  He also noted: ‘Organizations that already have UL 60601-1 in their scope simply need to demonstrate that they have the capability to evaluate and test the product in the areas that we identified as being significantly different.’  I went onto the OSHA NRTL website to see how many labs have UL 60601-1 currently as an ‘Appropriate’ Standard for their labs and of the 15 NRTL’s that exist 10 of them are approve d for this standard.  The NRTL’s that have UL 60601-1 as an ‘Appropriate’ Standard are noted in the below listing.  From the links in this listing you can click on them to go to the NRTL’s list of approved standards and also the locations of their test labs that fall under the NRTL program.:</span></p>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a title="Canadian Standards Association (CSA)" href="https://www.osha.gov/dts/otpca/nrtl/csa.html" target="_blank" rel="noopener noreferrer">Canadian Standards Association (CSA)</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a title="Curtis-Straus LLC (CSL)" href="https://www.osha.gov/dts/otpca/nrtl/csl.html" target="_blank" rel="noopener noreferrer">Curtis-Straus LLC (CSL)</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a title="Intertek Testing Services NA, Inc. (ITSNA)" href="https://www.osha.gov/dts/otpca/nrtl/its.html" target="_blank" rel="noopener noreferrer">Intertek Testing Services NA, Inc. (ITSNA)</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a title="MET Laboratories, Inc. (MET)" href="https://www.osha.gov/dts/otpca/nrtl/met.html" target="_blank" rel="noopener noreferrer">MET Laboratories, Inc. (MET)</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a title="QPS Evaluation Services Inc. (QPS)" href="https://www.osha.gov/dts/otpca/nrtl/qps.html" target="_blank" rel="noopener noreferrer">QPS Evaluation Services Inc. (QPS)</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a title="SGS North America, Inc. (SGS)" href="https://www.osha.gov/dts/otpca/nrtl/sgs.html" target="_blank" rel="noopener noreferrer">SGS North America, Inc. (SGS)</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a title="TUV Rheinland of North America, Inc. (TUV)" href="https://www.osha.gov/dts/otpca/nrtl/tuv.html" target="_blank" rel="noopener noreferrer">TUV Rheinland of North America, Inc. (TUV)</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a title="TÜV SÜD America, Inc. (TUVAM)" href="https://www.osha.gov/dts/otpca/nrtl/tuvam.html" target="_blank" rel="noopener noreferrer">TÜV SÜD America, Inc. (TUVAM)</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a title="TÜV SÜD Product Services GmbH (TUVPSG)" href="https://www.osha.gov/dts/otpca/nrtl/tuvpsg.html" target="_blank" rel="noopener noreferrer">TÜV SÜD Product Services GmbH (TUVPSG)</a></span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><a title="Underwriters Laboratories Inc. (UL)" href="https://www.osha.gov/dts/otpca/nrtl/ul.html" target="_blank" rel="noopener noreferrer">Underwriters Laboratories Inc. (UL)</a></span></li>
</ul>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Once OSHA’s NRTL Program reviews the Lab’s submission assuming an acceptable submission and the application is complete with minimal Q&amp;A back and forth with the NRTL my contact says then they can do a ‘fairly quick review’ and if that is the case he is expecting ‘the preliminary [Federal Register] notice(s) around early May’ for this initial one or more applications.  He goes on to say: ‘with the final notice(s), officially recognizing the NRTL for the standard’ being issued in the Federal Register around ‘sometime in Mid-June’.  He also says ‘Others will follow later depending on when they applied and the completeness of the application.’</span></p>
<h2><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, What Does This Boil Down To? </span></h2>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">This means that at least one of the NRTL’s, and possibly more, that previously had approval for UL 60601-1 has already submitted an application to OSHA to be approved as a NRTL under the newer ‘Appropriate NRTL Program Standard’ ANSI/AAMI ES60601-1:2005/(R)2012 Medical electrical equipment, Part 1: General requirements for basic safety and essential performance (with amendments) and if things go smoothly, as expected this one or possibly more labs will be able to test and certify to this standard and issue an OSHA NRTL Certification Mark for the US that the medical device manufacture will be able to place on their product.  For more than 8 years this has not been possible and it is likely we are talking til at least June if not a bit longer before it is formally announced through a Final Federal Register Announcement.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Examples of the NRTL US or US &amp; Canada Marks are below (is not a complete list of NRTL&#8217;s that have approval for UL 60601-1):</span></p>
<p><img decoding="async" class="alignnone" style="font-family: arial, helvetica, sans-serif; font-size: small;" src="https://www.osha.gov/dts/otpca/nrtl/images/ETL-USC.jpg" alt="" width="62" height="49" /><img loading="lazy" decoding="async" class="alignnone" style="font-family: arial, helvetica, sans-serif; font-size: small;" src="https://www.osha.gov/dts/otpca/nrtl/images/sgs.jpg" alt="" width="55" height="54" /><img loading="lazy" decoding="async" class="alignnone" style="font-family: arial, helvetica, sans-serif; font-size: small;" src="https://www.osha.gov/dts/otpca/nrtl/images/tuvam-new-small.jpg" alt="" width="62" height="55" /><img loading="lazy" decoding="async" class="alignnone" style="font-family: arial, helvetica, sans-serif; font-size: small;" src="https://www.osha.gov/dts/otpca/nrtl/images/tuv2010.jpg" alt="" width="54" height="54" /><img loading="lazy" decoding="async" class="alignnone" style="font-family: arial, helvetica, sans-serif; font-size: small;" src="data:image/jpeg;base64,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" alt="" width="65" height="55" /><img loading="lazy" decoding="async" class="alignnone" style="font-family: arial, helvetica, sans-serif; font-size: small;" src="https://encrypted-tbn2.gstatic.com/images?q=tbn:ANd9GcS7fOC2uL3RWuaUZ2lwNzzSquaXOsvimPNrDXniT3Gi_UtLVDyrwQ" alt="" width="69" height="56" /></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, are you ready for ANSI/AAMI ES60601-1:2005/(R)2012 + A1 yet?  If, not and you want a NRTL Mark on your device you should start looking at what you need to do to update from either 3<sup>rd</sup> edition or 2<sup>nd</sup> edition of the standard if you have previously had your product tested &amp;/or certified to these versions of the standard.</span></p>
<h2><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Oppps a Mistake in the Announcement about Future Standards:</span></h2>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">In the Final Notice OSHA mentioned the comments they received briefly and one of them was from Mr. Dale Hallerberg of TÜV Rheinland North America (<strong><a href="http://www.regulations.gov/#!documentDetail;D=OSHA-2013-0012-0007" target="_blank" rel="noopener noreferrer">OSHA-2013-0012-0007</a></strong>).  You can access all <strong><a href="http://www.regulations.gov/#!docketDetail;D=OSHA-2013-0012" target="_blank" rel="noopener noreferrer">the comments to these notices right here</a></strong>. In Dale’s original comments he said “Correct the standard name in Table 1 to reflect the proper designations, title, and number. Also include all corrigendum and amendment(s). This will include the current A1 as well as possible future amendments.  ANSI/AAMI ES 60601-1 including corrigendum and amendment(s)”  There were a couple other people that commented about the standard reference being wrong in the preliminary notice. </span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">But more importantly Dale went on to say: ‘Include 60601-1 collateral and particular standards in Table 1. &#8220;Collateral standards to the 60601-1 base standard: 60601-1-2, -1-3, -1-6, -1-8, -1-10, -1-11, and -1-12 as appropriate for the workplace safety of the product. ANSI versions shall be used when they exist.&#8221;  And also he said ‘Since it is impossible to keep up an accurate (list) of all the particulars, add them in a general way as follows: &#8220;Particular standards to the 60601-1 base standard as appropriate for the workplace safety of the product. ANSI versions shall be used when they exist.&#8221;’  So, he is asking the OSHA NRTL program to allow the use all of the applicable 60601 series standards, for workplace safety, including the Collaterals (i.e. 60601-1-8 = Alarm system standard) and Particulars (i.e. 60601-2-18 Endoscopic camera medical devices standard).  He also asked that they shouldn’t have to be aligned with ANSI only.  Note, that OSHA has told me they will only use a US based standards development organization for the standards they list as ‘Appropriate’ and so that precludes any organization outside of the USA, such as IEC, ISO, CENELEC and CEN (European equivalents of IEC &amp; ISO respectively) to name a few.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">OSHA mistakenly printed the following text which has a few problems:</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“Mr. Dale Hallerberg stated that the list of appropriate standards should include, in addition to ANSI/AAMI ES60601-1:2005/(R)2012, standards that are collateral to ANSI/AAMI ES60601-1:2005/(R)2012, such as ANSI/AAMI ES60601-1-2 through ANSI/AAMI ES60601-1-12 (OSHA-2013-0012-0007).”</span></p>
<ol>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The first reference to “ANSI/AAMI ES60601-1:2005/(R)2012” doesn’t include the A1 which is critical to OSHA’s announcement as without A1 they would not be announcing this version of the standard.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The big issue is there are no such standards as ANSI/AAMI ES60601-1-2 through ANSI/AAMI ES60601-1-12. The closest thing to any of these references is there is an AAMI standard for 60601-1-11 which is actually ANSI/AAMI HA60601-1-11:2011 MEDICAL ELECTRICAL EQUIPMENT – Part 1-11:General requirements for basic safety and essential performance – Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment (IEC 60601-1-11:2010, MOD).  The only other collateral standard that is issued thru AAMI via ANSI is ANSI/AAMI/IEC </span><span style="font-family: arial, helvetica, sans-serif; font-size: small;">60601-1-2:2007/(R)2012 (EMC).  Also, OSHA did not mention in the Final Notice Dale’s reference to the Particular standards.  It is hard to know if that was a mistake or if they intentionally left out the reference to the Particular Standards for some reason.</span></li>
</ol>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If your company needs help with edition 3.0 or 3.1 for AAMI ES 60601-1 or IEC or EN 60601-1 gap analysis, preparation of the risk management file for these versions of the standard, or training on the Standard, please contact Leo Eisner at: <a href="mailto:Le&#111;&#64;&#69;&#105;&#115;ne&#114;Safet&#121;.c&#111;&#109;"><strong>Le&#111;&#64;&#69;i&#115;&#110;erSa&#102;&#101;&#116;&#121;&#46;com</strong></a>.  We have several associates that can assist with this type of work.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Sign-up for our monthly newsletter to keep up to date on all our posts.  Make sure to reply to the confirmation e-mail otherwise you won&#8217;t be signed up. (If you don’t see that e-mail check your spam or junk mail folders).</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Q&#038;A on OSHA NRTL for AAMI ES 60601-1 3rd ed. + A1</title>
		<link>https://eisnersafety.com/2014/01/11/qa-on-osha-nrtl-for-aami-es-60601-1-3rd-ed-a1/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=qa-on-osha-nrtl-for-aami-es-60601-1-3rd-ed-a1</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Sat, 11 Jan 2014 01:19:13 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[NRTL]]></category>
		<category><![CDATA[OSHA 60601]]></category>
		<category><![CDATA[OSHA Nationally Recognized Test Lab Program]]></category>
		<category><![CDATA[OSHA NRTL]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3591</guid>

					<description><![CDATA[A Q&#38;A post based on questions in the 25 Nov ‘13 post on OSHA to Add AAMI ES 60601-1 to ‘List of Appropriate’ NRTL Program Test Standards So, let’s answer the questions from the previous blog post about the OSHA]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">A Q&amp;A post based on questions in the <strong><a href="http://www.eisnersafety.com/osha-to-add-aami-es-60601-1-to-list-of-appropriate-nrtl-program-test-standards/">25 Nov ‘13 post on OSHA to Add AAMI ES 60601-1 to ‘List of Appropriate’ NRTL Program Test Standards</a></strong></span></p>
<p><span id="more-3591"></span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">So, let’s answer the questions from the <strong><a href="http://www.eisnersafety.com/osha-to-add-aami-es-60601-1-to-list-of-appropriate-nrtl-program-test-standards/">previous blog post about the OSHA NRTL program starting to establish and adding in the AAMI ES 60601-1 Standard</a></strong>.  Below are the questions I stated in the last blog post, on this subject, along with the replies from my OSHA contact and additional Q&amp;A.</span></p>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">1)  The first question was: “does that mean the Test Agencies … that have previously asked OSHA to add the US national version of 3rd ed. of the IEC 60601-1 standard to these lab&#8217;s &#8216;list of Appropriate&#8217; standards will be automatically added to that list?”</span><br />
<span style="font-size: small; font-family: arial, helvetica, sans-serif;">Additionally I asked: “And what will that qualification look like as now OSHA has to deal with qualifying the safety test agencies for the review and approval of the risk management process for medical electrical devices (a new concept for them I would suspect), among other potential issues?” </span></p>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The reply is “no” to the first question, they will not be automatically added in.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If a lab didn’t previously have UL 60601-1 in their scope, under the NRTL program, they wouldn’t have been sent a <strong><span style="text-decoration: underline;"><a href="http://www.eisnersafety.com/wp-content/uploads/2014/01/NRTL-letter-for-comparability_UL-60601.docx" target="_blank" rel="noopener noreferrer">letter from the OSHA NRTL program explaining the process to be able to be considered to add the AAMI ES 60601-1, 3<sup>rd</sup> ed. + Amendment 1 standard to their ‘List of Appropriate’ Standards</a></span></strong>.  So, if there is a lab without UL 60601-1 in their scope they will need to contact OSHA directly to request a review be conducted to AAMI ES 60601-1, provide the appropriate information, and pay the review application fee.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><span style="text-decoration: underline;"><a href="http://www.eisnersafety.com/wp-content/uploads/2014/01/NRTL-letter-for-comparability_UL-60601.docx">This letter</a></span></strong>, which was sent out the week of 16 Dec 2013 to the test labs that had UL 60601-1 in their scope when it was sent, and <strong><span style="text-decoration: underline;"><a href="http://www.eisnersafety.com/wp-content/uploads/2014/01/NRTL-letter-for-comparability_UL-60601.docx" target="_blank" rel="noopener noreferrer">is available here for your reference</a>.</span></strong>  It shows that the test labs that want to get approved for this new standard will need to provide some documentation to OSHA to prove they have the capability for meeting the differences from the UL 60601-1 standard to the AAMI ES 60601-1, 3<sup>rd</sup> ed. +A1 standard.  My OSHA contact said <em><strong><span style="text-decoration: underline;">they are not asking for any specific evidence that the test agency is capable of dealing with the Risk Management requirements of the AAMI ES 60601-1 standard</span></strong></em>.  This was surprising to me but once I understood his response I wasn’t too surprised as I learned a lot about the program and the process by asking all these questions.  My contact stated the following: “While it” [Risk Management] “forms an important aspect of the standard, for OSHA’s purposes, we believed that Risk management played a very small part in the overall electrical safety, and the capability necessary to look at risk management was similar to that used in other electrical safety standards.”</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">My contact summarized the process that the labs would go through to get authorized for the AAMI ES 60601-1 standard.  Note this was written before the letter was issued so this is the general steps to the process of a test lab asking for an expansion of their List of Appropriate Standards.  “OSHA will be contacting NRTLs with UL60601-1 in their scopes, providing details of the information they will need to provide to request an expansion to AAMI ES 60601-1.  OSHA will review the application submittals, make a determination of acceptability, and publish a preliminary and final Federal Register notices before an NRTL can officially be considered recognized for AAMI ES 60601-1.”</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">The <strong><span style="text-decoration: underline;"><a href="http://www.eisnersafety.com/wp-content/uploads/2014/01/NRTL-letter-for-comparability_UL-60601.docx" target="_blank" rel="noopener noreferrer">letter</a></span></strong> states the following important issues.  Some of which the test labs will need to have reconciled before OSHA will add the AAMI ES 60601-1 standard to that test lab’s ‘List of Appropriate’ standards:</span></li>
</ul>
</ul>
<ul>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“OSHA believes that AAMI ES60601-1 is not completely comparable to UL 60601-1.  Therefore, pursuant to the requirements in 29 CFR 1910.7(b)(1), OSHA will only modify the scope of recognition of [Test Lab Name] to include AAMI ES60601-1, if [Test Lab Name] submits information that demonstrates capability to those replacement test standards,”</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“OSHA has evaluated AAMI ES60601-1 against UL 60601-1 and has noted the substantive differences between the two standards.  To add this new standard to your scope of recognition [Test Lab Name] must provide evidence that they have addressed those substantive differences.  Table 1 contains a list of those requirements in AAMI ES60601-1 that differ substantively from UL 60601-1. [Test Lab Name] will need to submit information to demonstrate their capability to address these substantive differences.” </span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“Adding this standard to your scope is an expansion of your recognition.”  The cost to apply for the expansion review is only $300 but OSHA can invoice the test lab for any additional remaining fees before they announce the expansion when approved.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Lastly, if the test lab decides not to apply to request the expansion prior to the removal of UL 60601-1 from OSHA’s list of ‘Appropriate test standards’ UL 60601-1 will be removed from the test labs scope and the lab will no longer be recognized to test or certify there type of products.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">My OSHA contact has indicated that when ANSI or UL has withdrawn UL 60601-1 the standard will be removed from OSHA’s list of ‘appropriate test standards.’  The letter just doesn’t make reference to the US Standards Development Organizations (ANSI, UL, etc.) but says the same basic information.</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Table 1 only covers 6 specific tests requirements OSHA is concerned with and 1 item specific to additional evaluation of lithium batteries (Sub-clause 15.4.3.4).   The 6 test requirements are for Acoustic Energy (Sub-clause 9.6), Pressure vessels and parts subject to pneumatic and hydraulic pressure (sub-clause 9.7.2 – 9.7.4), Pressure control device (Sub-clause 9.7.6), Mechanical hazards associated with support systems (Sub-clause 9.8), Oxygen Rich Environments (Sub-clause 11.2.1 &#8211; this is the only test that the test lab may opt out of conducting the test if they don’t have the capability), and Rough handling test (Sub-clause 15.3.5).</span></li>
</ul>
</ul>
</ul>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">2)  “How long will” the qualification process “take?”  </span></p>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">When I talked to my contact at OSHA I expanded this question to the following: “How long will it take to first get the standard added to the “Appropriate Standards Listing” and then from there how long to get the first couple of labs qualified as a NRTL under AAMI ES 60601-1 + A1?  I am hoping this can all turn around by end of 1<sup>st</sup> quarter but suspect it will be more like end of 2<sup>nd</sup> quarter.”</span></li>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">His response was: ‘The Final notice’ (in the Federal Register) ‘announcing the AAMI standard as an “appropriate test standard” is expected to be published sometime in January.  NRTLs can submit an application for the AAMI standard at any time, and the ultimate date when NRTLs will be recognized depends to a great extent on the quality and completeness of the application, as well as when the application is actually received.  1<sup>st</sup> quarter 2014 is possible (although very tight), but 2<sup>nd</sup> Quarter is very reasonable.’</span></li>
</ul>
</ul>
</ul>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">3)  I noted in the last post on this topic that OSHA had a major typo in the Federal Register notice so I asked this question of my contact: “Note that I checked the Federal Register announcement just now and it still shows the IEC 60601-1-2 standard title being the EMC standard.  What is the plan for the new update to the 60601-1 + A1 standard title and standard number listing?  Are you planning to use the full standard reference like I did in my blog post such as AAMI ES 60601-1:05/(R):12 + A1:12 + C1:09/(R):12 + A2:10/(R):12 (this is the US National version of IEC 60601-1:05 + A1:12) or what and when should this change show up in this listing or will it be a separate update?”</span></p>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">My contact’s response was: “We plan on issuing a formal correction in the Federal Register notice when we publish the final Federal Register notice (anticipated sometime in January).  Once a FR Notice is published, you cannot amend it, you can only issue a correction in a separate notice.  Such a correction would take just as long to process as a Final notice, so the decision was made to include the correction in the final notice.”</span></li>
</ul>
</ul>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">4)  The last question I asked in my previous NRTL post was: “will the Safety Agencies be able to leverage from previous testing done by these Safety Test Agencies or will they need to start a totally new test project before they can issue the NRTL mark for this standard?”</span></p>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">My OSHA contact’s response states: “It will be possible for the NRTLs to make use of some of the evaluation and testing conducted before they were recognized as an NRTL.  NRTLs will need to formally document this review.  However, OSHA is only recognizing A1 and later, so any evaluation and testing done to AAMI ES 60601-1:05 will need to be at least partially re-examined and possibly retested to ensure that the requirements of A1 are fully complied with.”</span></li>
</ul>
</ul>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">5)  After my previous post on the OSHA NRTL issues I wrote to my contact at OSHA and asked some additional questions which are noted here for your reference as I realized there were some other pertinent questions to ask.</span></p>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">“As you know there are numerous particular standards pending review/revision to reflect the new requirements introduced by A1” [Amendment 1] “of 3rd ed. and thus the AAMI ES 60601-1 ed. 3.1 (or 3rd ed. + A1) with the collaterals can only be used for products where such particulars are not applicable” [as they aren’t aligned to A1 of 60601-1 yet as they haven’t been published yet.]. “So the majority of products cannot be certified to ed. 3.1 yet.  Does OSHA have any plans how they will deal with this issue&#8230;Do you plan to add any US national collaterals (60601-1-XX) and/or if there are any US national particular standards (60601-2-XX)” [Such as AAMI/ANSI IEC/ISO 80601-2-58].  “Are there any of the collateral and particular standards covered under a US SDO” [Standards Development Organization] “like ANSI or AAMI?  How will the OSHA NRTL program deal with the collaterals and the particulars…?”</span></li>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">My contact’s response was: ‘OSHA Regulations, specifically 29 CFR 1910.7(c), requires that test standards recognized under the NRTL program be “Recognized in the United States as a safety standard providing an adequate level of safety” Historically, this has meant that the standard has been developed or adopted by a US based Standards Development Organization (SDO) which were often designated as an ANSI or ASTM standard.  If a collateral or particular standard has not been “Recognized in the United States as a safety standard providing an adequate level of safety”, it cannot be designated as an “appropriate test standard” under the NRTL Program.  In other words, unless the IEC60601-1-XX and IEC 60601-2-XX standards are developed or adopted by a US SDO, we are unable to include them as appropriate test standards for the NRTL program under our current regulations. If particulars or collaterals are adopted by a US SDO, and the standard is requested to be reviewed as an appropriate test standard as part of an expansion request by an NRTL, or by an industry/trade group, or another stakeholder, OSHA will review the standard to ensure that it meets the requirements in 29 CFR 1910.7(c).’</span></li>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">His response basically means that OSHA has not considered any additional US Based SDO standards in the 60601 series based on the AAMI ES 60601-1, 3<sup>rd</sup> ed. + A1 to be added to the NRTL List of Appropriate Standards.  There are no IEC and therefore AAMI or ANSI/AAMI standards in the 60601 series that have been published yet that include A1 of 3<sup>rd</sup> ed. of 60601-1.  The process for the IEC Particulars and Collaterals standards incorporating the 60601-1, 3<sup>rd</sup> ed. + A1 changes into these standards is just about to start in the development process and so it will take a year or so before they are published as International Standards.  Only a portion of them will be published as US based standards, if the lead for that group is run through the US national committee, either at the same time or after the IEC standard is published.</span><br />
<span style="font-size: small; font-family: arial, helvetica, sans-serif;"><strong><em><span style="text-decoration: underline;">So when these IEC based standards finally are updated to include the A1 changes and if they are also developed under a US SDO you could request that the OSHA NRTL program consider reviewing that specific standard to be added to the list of “appropriate standards”.</span></em></strong></span></li>
</ul>
</ul>
</ul>
<p style="padding-left: 30px;"><span style="font-size: small; font-family: arial, helvetica, sans-serif;">6)  Previous to the OSHA NRTL post I also asked my OSHA contact a question why they didn’t use the 3<sup>rd</sup> ed. without the Amendment 1 as that could have been done a long time ago and then a NRTL mark could have been used now for many years.  </span></p>
<ul>
<ul>
<li><span style="font-size: small; font-family: arial, helvetica, sans-serif;">His reply was: “The Concerns we had with the original issuance of AAMI ES 60601-1 were the numerous subjective compliance requirements, as well as statements in the standard that would have required the NRTL to accept statements from the manufacturer without the ability for the NRTL to verify the validity of these statements. The text of the standard therefore directly conflicted with the NRTL program requirements, which require the NRTL to make the final decision on testing and certification decisions. The changes in language introduced in A1 allowed the NRTL to accept data from the manufacturer, and verify the validity of that data. When we first reviewed AAMI ES 60601-1, we noted several areas that conflicted with the NRTL Program requirements, and the changes made in A1 aligned almost exactly with the clauses where we had concerns.”</span></li>
</ul>
</ul>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">If your company needs help with edition 3.0 or 3.1 for AAMI ES 60601-1 or IEC or EN 60601-1 gap analysis, preparation of the risk management file for these versions of the standard, or training on the Standard, please contact Leo Eisner at: <a href="mailto:Le&#111;&#64;Eisn&#101;r&#83;a&#102;ety&#46;&#99;o&#109;"><strong>&#76;eo&#64;&#69;&#105;s&#110;e&#114;&#83;a&#102;e&#116;&#121;&#46;&#99;om</strong></a>.  </span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">Sign-up for our monthly newsletter to keep up to date on all our posts.  Go to the upper left hand corner of any page on the site and sign-up to enjoy articles like this.  Make sure to reply to the confirmation e-mail otherwise you won&#8217;t be signed up. (If you don’t see that e-mail check your spa or junk mail folders).</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>OSHA to Add AAMI ES 60601-1 to &#8216;List of Appropriate&#8217; NRTL Program Test Standards</title>
		<link>https://eisnersafety.com/2013/11/25/osha-to-add-aami-es-60601-1-to-list-of-appropriate-nrtl-program-test-standards/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=osha-to-add-aami-es-60601-1-to-list-of-appropriate-nrtl-program-test-standards</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Mon, 25 Nov 2013 07:26:30 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[AAMI]]></category>
		<category><![CDATA[AAMI ES 60601-1 2005/A1 2012]]></category>
		<category><![CDATA[AAMI ES 60601-1:05/(R):12 + A1:12 + C1:09/(R):12 + A2:10/(R):12]]></category>
		<category><![CDATA[AAMI ES 60601-1:05/A1:12]]></category>
		<category><![CDATA[AAMI ES 60601-1:2005 / A1:2012]]></category>
		<category><![CDATA[AAMI ES 60601-1:2005/A1:2012]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[AAMI ES60601-1/C1]]></category>
		<category><![CDATA[Amendment 1]]></category>
		<category><![CDATA[ANSI/AAMI ES 60601-1:2005/A1:2012]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[Federal Register]]></category>
		<category><![CDATA[Federal Register Announcement]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[ISO 14971]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[Nationally Recognized Test Labs]]></category>
		<category><![CDATA[NRTL]]></category>
		<category><![CDATA[osha]]></category>
		<category><![CDATA[OSHA Nationally Recognized Test Lab Program]]></category>
		<category><![CDATA[Risk Management]]></category>
		<category><![CDATA[Risk Management Process]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3548</guid>

					<description><![CDATA[OSHA adding AAMI ES 60601-1 to the &#8216;List of Appropriate&#8217; NRTL Program Test Standards is discussed in this blog. BIG News!!!  News, I have been waiting for many years now is that OSHA, finally, under it&#8217;s NRTL (Nationally Recognized Test]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">OSHA adding AAMI ES 60601-1 to the &#8216;List of Appropriate&#8217; NRTL Program Test Standards is discussed in this blog.</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;">BIG News!!!  News, I have been waiting for many years now is that OSHA, finally, under it&#8217;s NRTL (Nationally Recognized Test Lab) program will be adding the US National version of the IEC 60601-1:05 + A1:12 medical electrical safety standard (= AAMI ES 60601-1:05/(R):12 + A1:12 + C1:09/(R):12 + A2:10/(R):12) to their &#8216;List of Appropriate&#8217; NRTL Program Test Standards.  <strong><a href="https://www.federalregister.gov/articles/2013/11/25/2013-28093/proposed-revision-of-policy-for-incorporating-new-test-standards-into-the-list-of-appropriate-nrtl" target="_blank" rel="noopener noreferrer">The announcement in the Federal Register</a></strong> is dated for 25 November 2013 but the list won&#8217;t be updated until at least early next year as comments, information, &amp; documents in response to the notice, or requests for extension of time to make a submission are due by 26 December 2013.<br />
</span></p>
<p><span style="font-size: small; font-family: arial, helvetica, sans-serif;"><span id="more-3548"></span></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">What&#8217;s that mean to those manufacturers that have been waiting years to get a NRTL US Mark for their medical electrical product to 3rd ed. of 60601-1?  It means that OSHA is just announcing they are adding this standard to the &#8216;list of Appropriate Standards&#8217; sometime early next year, if things run smoothly.  But does that mean the Test Agencies like UL, CSA, TÜV SÜD, &amp; Intertek that have previously asked OSHA to add the US national version of 3rd ed. of the IEC 60601-1 standard to these lab&#8217;s &#8216;list of Appropriate&#8217; standards will be automatically added to that list?  My guess, at this point, is that OSHA will have to qualify each test lab that wants to be added to this list for AAMI ES 60601-1.  How long will this take?  And what will that qualification look like as now OSHA has to deal with qualifying the safety test agencies for the review and approval of the risk management process for medical electrical devices (a new concept for them I would suspect), among other potential issues?  That&#8217;s a good set of questions and I have an e-mail into OSHA to ask all these types of questions and when I get some feedback from them I will send an update out to all of you.  </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Note, the Notice in the Federal Register had a fairly major typo, which I already pointed out to my contact, and that is the notice should have identified the standard as AAMI ES 60601-1:05/(R):12 + A1:12 + C1:09/(R):12 + A2:10/(R):12 (this is the US National version of IEC 60601-1:05 + A1:12) and instead they had a big set of typos that says in this notice &#8220;AAMI ES 60601-1&#8221; (they missed all the details to id it as Amendment 1 &#8211; Ooooops) and the title they refer to is &#8220;Medical Electrical Equipment—<em><span style="text-decoration: underline;"><strong>Part 1-2</strong></span></em>: General requirements for Basic Safety and Essential Performance—<em><span style="text-decoration: underline;"><strong>Collateral Standard: Electromagnetic Compatibility</strong></span></em> (third edition)&#8221;.  The items that are <em><span style="text-decoration: underline;"><strong>underlined, bolded and italicized</strong></span></em> are the wrong standard name.  And I believe they should be very specific for this version of the standard and that is why I am pointing out the full AAMI ES identifier in this post and sending it to my contact at OSHA. He already said they are checking into the typos</span><span style="font-family: arial, helvetica, sans-serif; font-size: small;">.  Hopefully the typos can be fixed quickly so that it doesn&#8217;t slow down the process anymore.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">So, hopefully by mid next year, or hopefully before then, OSHA will be able to say they have one or more of the NRTL&#8217;s online for issuing NRTL safety agency marks as that will mean those safety test agencies will be able to start to issue the NRTL mark to the AAMI ES 60601-1:05/(R):12 + A1:12 + C1:09/(R):12 + A2:10/(R):12 version of the standard.  So, another question comes up will the Safety Agencies be able to leverage from previous testing done by these Safety Test Agencies or will they need to start a totally new test project before they can issue the NRTL mark for this standard?  I will make sure that OSHA get&#8217;s all these questions and hopefully they will be able to respond to these questions and answers publicly.  That I really am not sure about yet. </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">If your company needs help with edition 3.0 or 3.1 for AAMI ES 60601-1 or IEC or EN 60601-1 gap analysis, preparation of the risk management file for these versions of the standard, or training on the Standard, please contact Leo Eisner at: <a href="mailto:L&#101;&#111;&#64;E&#105;&#115;&#110;&#101;rSafe&#116;&#121;.c&#111;&#109;"><strong>&#76;&#101;&#111;&#64;&#69;isner&#83;&#97;fet&#121;&#46;c&#111;m</strong></a>.  </span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Sign-up for our monthly newsletter to keep up to date on all our posts.  Go to the upper left hand corner of any page on the site and sign-up to enjoy articles like this.  Make sure to reply to the confirmation e-mail otherwise you won&#8217;t be signed up.</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDA Extends AAMI ES 60601-1 Transition Date to 31 Dec &#8217;13 &#038; Other Important Changes &#8211; Recognition Lists 031/032</title>
		<link>https://eisnersafety.com/2013/08/06/fda-extends-aami-es-60601-1-transition-date-to-31-dec-13-other-important-changes-recognition-lists-031032/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fda-extends-aami-es-60601-1-transition-date-to-31-dec-13-other-important-changes-recognition-lists-031032</link>
		
		<dc:creator><![CDATA[leoeisner]]></dc:creator>
		<pubDate>Tue, 06 Aug 2013 10:37:09 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[031]]></category>
		<category><![CDATA[032]]></category>
		<category><![CDATA[60601 series]]></category>
		<category><![CDATA[60601-1]]></category>
		<category><![CDATA[60601-1 3rd ed.]]></category>
		<category><![CDATA[A1]]></category>
		<category><![CDATA[AAMI]]></category>
		<category><![CDATA[AAMI ES60601-1]]></category>
		<category><![CDATA[AAMI ES60601-1/C1]]></category>
		<category><![CDATA[Amendment 1]]></category>
		<category><![CDATA[ANSI/AAMI ES60601-1]]></category>
		<category><![CDATA[CDRH]]></category>
		<category><![CDATA[Collateral Standard]]></category>
		<category><![CDATA[consens]]></category>
		<category><![CDATA[Consensus Standard]]></category>
		<category><![CDATA[consensus standards]]></category>
		<category><![CDATA[Consensus Standards List 031]]></category>
		<category><![CDATA[Consensus Standards List 032]]></category>
		<category><![CDATA[ESCNews]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[FDA Guidance]]></category>
		<category><![CDATA[FDA Recognition List 031]]></category>
		<category><![CDATA[FDA Recognition List 032]]></category>
		<category><![CDATA[FDA Recognized Consensus Standards]]></category>
		<category><![CDATA[FDA's Recognition List 031]]></category>
		<category><![CDATA[FDA's Recognition List 032]]></category>
		<category><![CDATA[Guidance Document]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[iec 60601]]></category>
		<category><![CDATA[IEC 60601-1]]></category>
		<category><![CDATA[IEC60601-1]]></category>
		<category><![CDATA[IEC60601-1 3rd ed.]]></category>
		<category><![CDATA[IEC60601-1-11]]></category>
		<category><![CDATA[List 031]]></category>
		<category><![CDATA[List 032]]></category>
		<category><![CDATA[Medical]]></category>
		<category><![CDATA[Medical Device]]></category>
		<category><![CDATA[Medical Device Industry]]></category>
		<category><![CDATA[Medical Device Regulatory]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[medical electrical equipment]]></category>
		<category><![CDATA[NRTL]]></category>
		<category><![CDATA[osha]]></category>
		<category><![CDATA[OSHA Nationally Recognized Test Lab Program]]></category>
		<category><![CDATA[premarket submissions]]></category>
		<category><![CDATA[Recognized Consensus Standard]]></category>
		<category><![CDATA[Recognized Consensus Standard Database]]></category>
		<category><![CDATA[Recognized Consensus Standards]]></category>
		<category><![CDATA[Recognized Consensus Standards List 031]]></category>
		<category><![CDATA[Recognized Consensus Standards List 032]]></category>
		<guid isPermaLink="false">http://www.eisnersafety.com/eisnersafetycom/?p=3444</guid>

					<description><![CDATA[The big news in the IEC 60601-1, 3rd ed. world today is the US National Standard that is in the FDA&#8217;s Recognized Consensus Standards Lists [Now is ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text) &#8211; Recognition List #:]]></description>
										<content:encoded><![CDATA[<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">The big news in the IEC 60601-1, 3rd ed. world today is the US National Standard that is in the FDA&#8217;s Recognized Consensus Standards Lists [Now is ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text) &#8211; <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">Recognition List #: 031</a></strong>, Recognition # 5-77] has had it&#8217;s transition date moved from June 30, 2013 to December 31, 2013.  So, if you are about to submit to the FDA for a pre-market submission you still may have a choice to use the IEC 60601-1, 2<sup>nd</sup> edition version of the standard instead of the US National Version of IEC 60601-1, 3<sup>rd</sup> ed.  You still may want to use the US National Version that is based on IEC  60601-1, 3<sup>rd</sup> ed. but now you have a choice again.  So, as of January 1, 2014 all your pre-market submissions to the FDA that rely on the US National version of the IEC 60601-1, 3rd ed. standard should be using this version of the standard (ANSI/AAMI ES60601-1:2005/(R)2012&#8230;, <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">Rec List #: 031</a></strong>, Rec #: 5-77).  Note, that use of the FDA&#8217;s Recognized Consensus Standards is voluntary but if you don&#8217;t use it realize the burden of proof is higher on your shoulders to prove to the FDA you meet the requirements they are expecting from you. </span></p>
<p><span id="more-3444"></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">From what I have determined the change in transition date is based on that OSHA’s NRTL (Nationally Recognized Test Laboratories) Program will be aligning with the FDA in terms of this standard and will hopefully be by the end of this year, if not sooner, they will be able to approve NRTL Test Labs to the US National Version of IEC 60601-1, 3<sup>rd</sup> ed. which probably will be ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text).  FDA has been intending to, and I hope they do, come out with a guidance document for premarket submissions of medical electrical equipment and what their expectations are for applying the US National Version of IEC 60601-1, 3<sup>rd</sup> edition.  Also, about 1-1/2 months ago FDA announced their concern about cyber-security for medical devices and hospital networks and so they issued a Safety Communication on June 13, 2013 to medical device manufacturers, hospitals, medical device user facilities, health care IT &amp; procurements staff; &amp; biomedical engineers; and <strong><a href="http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/UCM356190.pdf" target="_blank" rel="noopener noreferrer">they issued a draft guidance document on the issue</a></strong> on June 14, 2013.  To coordinate all these activities, draft guidance documents, and agencies FDA decided to extend the transition period for the US National version of IEC 60601-1, 3<sup>rd</sup> ed. equivalent.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">The IEC 60601 series of standards that FDA has Listed in the Recognized Consensus Standards Listing and some of the ISO 80601 series of standards that FDA has listed are updated in <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">List 031</a></strong> with this new transition date, unless it is a brand new standard being published on the List for the first time, along with other changes that were ready to be published.  The Cyber-security standards are listed in <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19020/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">Recognition List 032</a></strong> and are all new listings to the List of Recognized Consensus Standards.  There were many other changes with these Recognition Lists <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">031</a></strong> &amp; <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19020/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">032</a></strong> which will officially be published in the Federal Register as of 6 August 2013 and the changes will officially be effective then but have already been issued prior to August 6, 2013 in the FDA&#8217;s Recognized Consensus Database. (Either one or two days prior).</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">Below is a summary of the more critical changes, from my perspective, for <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">List 031</a></strong>.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">New Standards Added to the <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19019/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">FDA&#8217;s Recognition List 031</a></strong> (Table 2 of List 031) of significance are:</span></p>
<table style="width: 509px;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Recognition Number</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Title of Standard (Abbreviated)</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Standard Ref Number / Date of Issue</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Blog Comments</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">5-75</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical devices&#8211;Symbols to be used w/ med dvc labels, labeling, &amp; info to be supplied&#8211;Part 1</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/ISO 15223-1 / 2012</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Added the US National Version in addition to the ISO version which is Recognition # 5-73</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">17-11</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-10: Particular requirements for basic safety &amp; essential performance of nerve &amp; muscle stimulators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-10 Edition 2.0 / 2012-06</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Newer version of std.  Transition date set for Dec 31, 2013. So, on Jan 1, 2014 this ver. of the std will only be accepted.  Rec # 17-5, IEC 60601-2-10:1987 + Amendment 1 2001 accepted up til Dec 31, 2013. Note, the transition date info is not mentioned in Rec # 17-5.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-251</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med elect equip&#8211;Part 2-63: Particular requirements for basic safety &amp; essential performance of dental extra-oral X-ray equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-63 Edition 1.0 / 2012-09</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Brand new std added to Recognized Consensus Standards.  Since there isn’t a previous ver. of the std there is no transition date.  This means this std is effective on the date of publication of this Listing in the Federal Register which is 6 August 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-252</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med elect equip&#8211;Part 2-65: Particular requirements for basic safety &amp; essential performance of dental intra-oral X-ray equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-65 Edition 1.0 / 2012-09</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Same comments as above Rec. # 12-251.</span></td>
</tr>
</tbody>
</table>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">There were also modifications to the List of Recognized Stds (Table 1 of List 031) of some importance.  The 60601 related standards were updated to align with the transition period of ANSI/AAMI ES60601-1 std along with other changes of importance as noted below.</span></p>
<table style="width: 509px;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Recognition Number</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">(New)</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Title of Standard (Abbreviated)</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Standard Ref Number / Date of Issue</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Blog Comments</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">1-82</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-13: Particular requirements for basic safety &amp; essential performance of anaesthetic systems</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-13 Edition 3.1 / 2009-08</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Newer version of std.  Transition date set for Dec 31, 2013. So, on Jan 1, 2014 this ver. of the std will only be accepted.  Rec # 1-61, IEC 60601-2-13:2003-05 accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">1-88</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-12: Particular requirements for basic safety &amp; essential performance of lung ventilators &#8212; Critical care ventilators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ISO 80601-2-12 First Edition / 2011-04-15</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Newer version of std (previously was an IEC std and now an ISO std as it was done by a Joint Working group of IEC &amp; ISO committee members).  Transition date set for Dec 31, 2013. So, on Jan 1, 2014 this ver. of the std will only be accepted.  Rec # 1-60, IEC 60601-2-12:2001-10 accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">2-198</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Biological eval of med dvcs&#8211;Part 12: Sample prep &amp; ref mat’ls</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/ISO 10993 / 12:2012</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Newer US National Version of ISO 10993-12. Withdrawn the ANSI/AAMI/ISO 10993-12:2007 version of the std, Rec. # 2-135</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">2-174</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">(Published 03/16/2012)</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Biological eval of med dvcs—Part 10: Tests for irritation &amp; skin sensitization</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ISO 10993-10 Third Edition / 2010-08-01</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Withdrew older version of ISO version of the std. Refer to Rec. # 2-152, ISO 10993-10: 2002 / Amendment 1:2006</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">3-115</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-34: Particular requirements for basic safety &amp; essential performance of Invasive Blood Pressure Monitoring Euip</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-34 Edition 3.0 / 2011-05</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Newer version of std.  Transition date set for Dec 31, 2013. So, on Jan 1, 2014 this ver. of the std will only be accepted.  Rec # 3-38, IEC 60601-2-34:2000-10 accepted up til Dec 31, 2013 but it’s Rec # 3-38 has been deleted from the FDA Database.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">4-187</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-18: Particular requirements for basic safety &amp; essential performance of endoscopic equip</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-18 Edition 3.0 / 2009-08</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">FDA’s notice says transition period extended but when checked the database the transition period ended June 30, 2013 and is referring only to IEC 60601-1:2001 (Edition 2) and ANSI / AAMI ES60601-1:2005 which doesn’t correlate with the other listings. It seems like the database either hasn’t been updated for this item or got goofed up as of the evening of Aug 5<sup>th</sup>.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">5-53</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip &#8211; Part 1-2: General requirements for basic safety &amp; essential performance &#8211; Collateral std: Electromagnetic compat &#8211; Requirements &amp; tests</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-1-2 Edition 3.0  / 2007-03</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Transition period extended for this IEC version of the std from June 30, 2013 to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 5-34, IEC 60601-1-2, Edition 2:2001 + Amendment 1:2004 accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">5-54</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip &#8211; Part 1-2: General requirements for basic safety &amp; essential performance &#8211; Collateral std: Electromagnetic compat &#8211; Requirements &amp; tests</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-1-2 Edition 3.0  / 2007 (R)2012</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Transition period extended for US National version  (ANSI/AAMI/IEC) of the std from June 30, 2013 to Dec 31, 2013 and this std reaffirmed in 2012.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 5-35, ANSI/AAMI/IEC 60601-1-2, Edition 2:2001 + Amendment 1:2004 accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">5-76</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip &#8211; Part 1-8: General requirements for basic safety &amp; essential performance &#8211; Collateral std: General requirements, tests, &amp; guidance for alarm systems in med elect equip &amp; med elect systems</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-1-8 Edition 2.1 / 2012-11</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Withdrew Rec # 5-55 (IEC 60601-1-8 Ed.1:2003) and replaced with Rec #5-76 and extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 5-55 accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-300</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-21: Particular requirements for basic safety &amp; essential performance of infant radiant warmers</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-21 Edition 2.0 / 2009-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-300 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-9 (IEC 60601-2-21:1996 + A1:2000) accepted up til Dec 31, 2013.  In the extension note section of Rec # 6-300 there are a couple typos as they refer to 60601-2-19 instead of 60601-2-21.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-298</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-19: Particular requirements for basic safety &amp; essential performance of infant incubators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-19 Edition 2.0 / 2009-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-298 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-29 (IEC 60601-2-19 A1:1996-10) accepted up til Dec 31, 2013.  In the extension note section of Rec # 6-298 there are a couple typos as they refer to ANSI/AAMI/IEC 60601-2-19:2009 instead of IEC60601-2-19:2009-02</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-299</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Med electrical equip&#8211;Part 2-20: Particular requirements for basic safety &amp; essential performance of infant  radiant warmers</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-20 Edition 2.0 / 2009-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-299 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-32 (IEC 60601-2-20 A1:1996-10) accepted up til Dec 31, 2013.  In the extension note section of Rec # 6-299 there are a couple typos as they refer to ANSI/AAMI/IEC 60601-2-19:2009 instead of IEC60601-2-20:2009-02</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-227</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-21 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-227 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-146 (IEC 60601-2-21:1996 + A1:2000) accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-228</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical Electrical Equipment&#8211;Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-2 Edition 5.0 / 2009-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-228 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-46 (IEC 60601-2-2:2006) accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-229</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgery equipment and high frequency surgical accessories</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-2 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-229 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-46 (IEC 60601-2-2:2006) accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-230</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical Electrical Equipment&#8211;Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-19 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-230 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-29 (IEC 60601-2-19 A1:1996-10) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-231</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical Electrical Equipment&#8211;Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-20 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-231 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-32 (IEC 60601-2-20 A1:1996-10) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-233</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment &#8212; Part 2-52: Particular requirements for basic safety and essential performance of medical beds</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-52 Edition 1.0 / 2009-12</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #6-233 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 6-182 (IEC 60601-2-38:1996 + A1:1999) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-234</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-50 Edition 2.0 / 2009-03</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Change in contact person only.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">6-235</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical Electrical Equipment&#8211;Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-50 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Same as above comment.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">9-80</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment &#8212; Part 2-16: Particular requirements for basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-16 Third edition / 2008</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Withdrew Rec # 9-60 [IEC 60601-2-16 Edition 3.0 2008-04] and Rec # 9-63 [IEC 60601-2-16 (Third edition&#8211;2008)] replaced with Rec #9-80 and extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-60 &amp; 9-63 accepted up til Dec 31, 2013.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">9-61</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-18 Edition 3.0 / 2009-08</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #9-61 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-42 (IEC 60601-2-18:1996 + A1:2000) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">9-81</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-16: Particular requirements for basic safety and essential performance of hemodialysis, hemodiafiltration and hemofiltration equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/ IEC 60601-2-16 / 2012</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #9-81 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-72 (IEC 60601-2-16:1998) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">9-62</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-2: Particular requirements for the basic safety and essential performance of frequency</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">surgical equipment and high frequency surgical accessories</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-2 Edition 5.0 / 2009-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #9-62 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-46 (IEC 60601-2-2:2006) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">9-64</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgery equipment and high frequency surgical accessories</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">ANSI/AAMI/IEC 60601-2-2 / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec #9-64 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 9-46 (IEC 60601-2-2:2006) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-201</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-54 Edition 1.0 / 2009-06</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-201 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-34 (IEC 60601-2-7 Second Edition 1998-02) &amp; Rec # 12-127 (IEC 60601-2-32 Edition 1.0 1994) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-254</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-8: Particular requirements for the basic safety and essential performance of therapeutic</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">X-ray equipment operating in the range 10 kV to 1 MV</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-8 Edition 2.0 / 2010-11</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-254 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-54 (IEC 60601-2-8 1999-04) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-255</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-11 Edition 3.0 / 2013-01</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-255 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-133 (IEC 60601-2-11:1997 + A1:2004) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-202</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">procedures</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-43 Edition 2.0 / 2010-03</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-202 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-63 (IEC 60601-2-43 Edition 1.0 2000) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-256</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">tomography</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-44 Edition 3.1 / 2012-09</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-254 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-203 or 12-120 (IEC 60601-2-44 2002-11) accepted up til Dec 31, 2013.  Not clear if one or both are applicable.</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-204</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-28 Edition 2.0 / 2010-03</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-204 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-126 (IEC 60601-2-28 Edition 1.0 1993) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-205</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">equipment&#8211;Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">physiotherapy equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-5 Edition 3.0 / 2009-07</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-205 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-147 (IEC 60601-2-5 Edition 2.0 2000) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-206</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">equipment&#8211;Part 2-1: Particular requirements for the basic safety and essential performance of electron</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">accelerators in the range 1 MeV to 50 MeV</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-1 Edition 3.0 / 2009-10</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-206 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-152 (IEC 60601-2-1 1998 + A1:2002) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-207</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnostic</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-33 Edition 3.0 / 2010-03</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-207 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-189 (IEC 60601-2-33 Edition 2.2 2008) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-208</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">diagnostic laser equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-22 Third Edition / 2007-05</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-208 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-197 (IEC 60601-2-22 Edition 2.0 1995) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-209</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-37 Edition 2.0 / 2007-08</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-209 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-198 (IEC 60601-2-37:2004 + A2:2005) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-210</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">equipment&#8211;Part 1-3: General requirements for basic safety and essential performance&#8211;Collateral Standard: Radiation protection in diagnostic X-ray equipment</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-1-3 Edition 2.0 / 2008-01</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-210 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-199 (IEC 60601-1-3 1994) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-211</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment Part 2-29: Particular requirements for the basic safety and essential performance of</span><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">radiotherapy simulators</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-29 Edition 3.0 / 2008-06</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-211 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-200 (IEC 60601-2-29 Edition 2.0 1999) accepted up til Dec 31, 2013. </span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-256</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography CORRIGENDUM 1</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-44 Third edition / 2009</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Withdrew Rec # 12-224  [IEC 60601-2-2-44 2002-11] and Rec # 12-250 [IEC 60601-2-2-44 2002-11] replaced with Rec #12-256 and extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-224 &amp;12-250 accepted up til Dec 31, 2013.  Unable to totally confirm that Rec #’s 12-224 &amp; 12-250are linked to IEC 60601-2-44 2002-11].</span></td>
</tr>
<tr>
<td valign="top" width="77"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">12-236</span></td>
<td valign="top" width="180"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Medical electrical equipment&#8211;Part 2-45: Particular requirements for the safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices</span></td>
<td valign="top" width="99"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">IEC 60601-2-45 Edition 3.0 / 2011-02</span></td>
<td valign="top" width="153"><span style="font-family: arial, helvetica, sans-serif; font-size: x-small;">Rec # 12-236 extended transition period to Dec 31, 2013.  So, on Jan 1, 2014 this ver. of the std will only be accepted. Rec # 12-178 (IEC 60601-2-45 Edition 2.0 2001) accepted up til Dec 31, 2013. </span></td>
</tr>
</tbody>
</table>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">In a future blog post we may discuss <strong><a href="https://www.federalregister.gov/articles/2013/08/06/2013-19020/food-and-drug-administration-modernization-act-of-1997-modifications-to-the-list-of-recognized" target="_blank" rel="noopener noreferrer">Recognition List 032</a></strong> and the Cyber-security standards.</span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: small;">If you have any questions or if you would like our assistance with regard to these standards please feel free to contact us at L&#101;o&#64;&#69;&#105;&#115;n&#101;r&#83;&#97;f&#101;&#116;&#121;&#46;&#99;om.</span></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
